139-6978
IP66/67
Tools required
– Cross Screwdriver
Class I, ta = 25 °C
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.6 lb
Input
Box M20: 0.236 – 0.512 in
Output (luminaire connection)
Box M16: 0.177 – 0.394 in
139-6978
For connection of, 8 x FLC201-TW, max. 50 W, 650 mA
constant current, 1.5 – 55 V SELV, max. 80 ft to the
luminaires with a total of 18 AWG cable cross-section.
2.95
Installation Procedure
1) Open the driver box by loosening the 4 fastening
screws.
2) Fasten the driver box to the mounting surface
with suitable fastening material.
ATTENTION:
Ensure not to damage any electric
cable, water pipe or other devices while drilling
holes.
4.73
9.04
7.86
3) Switch off the mains electrical supply.
4) Connect cable via main cable gland and connect
to the appropriately marked terminals.
For through-wiring version, an additional screw
connection can be used. To do this, remove the
sealing plug in the additional screw connection.
5) For connecting the luminaires, please note the
wiring instructions that are included with the
luminaires.
6) Close the driver box and tighten the fastening
screws!
Mains connection 3 x 18 AWG
Luminaire connection 9 x 18 AWG
Luminaire connection
See assembly instruc-
tions luminaire
L = Phase
N = Neutral conductor
= Protective conductor
+ = DMX +
- = DMX -
S = Shield
Connection without wiring
Connection for through-wiring
Luminaire connection
Mains connection
DMX In 2 pol. + Shield
DMX In
DMX Out
Mains connection
Luminaire connection
DMX In
DMX Out
DMX Out 2 pol. + Shield