UP35-4481N26000-02/15
– REV.B1
Page 56 / 63
9.1
Maintenance Plan
DANGER
+
Due to the risk of hand or finger injury, never try to reach into the machine before having
assured that the machine is disconnected from the air supply. Disconnect the air supply
before changing the safety guard, the adapter and the dies.
CAUTION
+
Before starting maintenance, disassembly or repair work, the crimp machine must be
disconnected from air supply.
+
Maintenance work may be performed only by authorized and properly trained staff. The
housing and the covers in particular may only be removed by specially trained staff.
+
When working with the pneumatic Parallel Crimp Machine UP 35, do not wear loose
clothing, jewellery or long, loose hair that can get caught in the pneumatic Parallel Crimp
Machine UP 35.
+
Work with caution.
+
Wear protective gloves and safety glasses during lubrication work. Please pay attention
to the safety instructions in the “safety data sheet” of the grease.
Regular maintenance and cleaning of the parts which can be reached without opening the
machine will prolong the life of the machine. Do not use rough materials to clean the
machine such as wire wool. The machine and or machine part should not be cleaned with
compressed air. The crimping machine as well as the machine parts must not be cleaned
with hard objects like scrapers, steel wool or similar.
Vacuum heavily soiled parts and wear.
9.1.1
Daily
+
Visual inspection of the pneumatic Parallel Crimp Machine UP 35.
+
Check air pressure (max. 6 bar) of the house installation (manometer not in the scope of
the delivery).
+
Check oil-level of service unit of the house air supply (not in the scope of the delivery).