background image

Switch-Over Automatic, type UMAP NT35-R

 

 

 

Index: 03 

Date modified: 28/03/2022 

OI No.: BA SW 017-03 Umschaltautomatik Typ UMAP NT35-R EN.docx 

Page 7 of 14

 

3.3

 

Identification of the device / identification plate 

Identification plate Switch-over automatic type NT 35-R 

Enter the data from the identification plate of your device here. 

 

 

Field 1:   Enter serial number  

 
 
Field 2:   Enter date of manufacturing 
 

 
 
 

3.4

 

Technical data 

 

Switch-over automatic type UMAP NT35-R 

Dimensions and weights:  

 

Dimensions  

W 20 cm, D 11 cm, H 40 cm 

Space requirement, including operation 
and maintenance 

W 70 cm, D 100 cm, H 200 cm 

Empty weight / operating weight 

approx. 2 kg / 25 kg 

 

 

Connection data 

 

Electrical connection data 

110-240VAC, 50-60Hz; safety plug 

Fuse  

Round fuse 1A slow 

Hydraulic connection data 

Hose connection for suction lances: 4x1, ¼“ (standard) 

Sewer connection (recommended) 

At least DN25 

Protection class 

IP44  

 

 

Operating data:  

 

Medium temperature 
Ambient temperature 
Humidity technical room  

5°C to 35°C 
5°C to 35°C 
max.: 80% (non-condensing)   

Room ventilation (in and out) 

According to DIN 19643 

Material 

Mounting plate: PP 
Housing: PS 
Seals: EPDM, Viton 

3.5

 

Transport / storage 

Please check the devices immediately upon receipt for potential transport damage. 

 

ATTENTION! 

The device may be damaged by frost or high temperatures.  
Do not store the device near objects with significant heat radiation or in direct 

sunlight. The device may only be transported and stored in its original packaging. 
Please ensure careful handling. 

 

Storage of chemicals 

 

DANGER! 

Pay attention to the chemical suppliers’ safety data sheets! 
In addition, please pay attention to the provision regarding the storage of chemicals 

TRGS 515. 

 

 

___________ 

___.___._________ 

Summary of Contents for UMAP NT35-R

Page 1: ...Item No OI No BA SW 017 03 Umschaltautomatik Typ UMAP NT35 R EN docx Language EN Operating and installation instructions Switch Over Automatic Type UMAP NT35 R...

Page 2: ...mmissioning 8 4 4 Description of the control 9 4 5 Replenish consumables 9 5 Maintenance care faults 10 5 1 Device maintenance 10 Open and close the housing 10 5 2 Trouble shooting 10 6 Decommissionin...

Page 3: ...ces as well as general notices DANGER DANGER denotes a safety notice which if disregarded may lead to serious or life threatening injuries or serious material damage CAUTION CAUTION denotes a safety n...

Page 4: ...ar For these we assume a warranty of 1 2 year Our merchandise management programme requires an invoice for each delivery including warranty services When returning a defective component upon review yo...

Page 5: ...and the chemicals intended for the chlorination must be stored in lockable rooms Re Section 3a Para 1 This requirement ensures that chlorination systems and chemicals shall be protected against weath...

Page 6: ...oups Control electronic 2 suction sets with empty indicator foot valve and container cover 3 2 way switchover solenoid valve for switching between containers Figure 1 Switchover solenoid valve Options...

Page 7: ...ic connection data Hose connection for suction lances 4x1 standard Sewer connection recommended At least DN25 Protection class IP44 Operating data Medium temperature Ambient temperature Humidity techn...

Page 8: ...Mount the external dosing pump in a suitable location for example next to the mounting plate c Attach warning and notice signs in accordance with the locally applicable accident prevention regulation...

Page 9: ...er the LED Container 1 goes out Suction continues from Container 2 d Only once Container 2 is empty the system switches back to Container 1 If Container 1 is still empty the dosing is automatically sw...

Page 10: ...following applies for work on electronic components Never plug in or remove connectors unless the power has been deactivated As the person handling the device please discharge yourself electrostatical...

Page 11: ...suction lances until the lines are clean control via the float switches 4 Disconnect the device from the power supply ATTENTION When recommissioning observe the instructions in the Commissioning chap...

Page 12: ...Switch Over Automatic type UMAP NT35 R Index 03 Date modified 28 03 2022 OI No BA SW 017 03 Umschaltautomatik Typ UMAP NT35 R EN docx Page 12 of 14 7 Documents 7 1 Declaration of conformity...

Page 13: ...Page 13 of 14 7 2 Wiring diagrams DANGER Risk of death due to high voltage All electrical work on the device must only be carried out by trained specialists in accordance with the applicable safety re...

Page 14: ...0 Ribbon cable 10 pole L 300 mm 19541 Bulkhead connector PP 4x1 on both sides 11003 Union nut d 6 PP 1 4 15077 Hose PVC transparent 4 0x1 0 mm 12252 Suction lance NF d16 500 4x1 with empty switch thre...