1

 

About these instructions / general 

1.1

 

Scope of applicability 

These  instructions  describe  the  functioning,  installation,  commissioning  and  operation  of  the  switch-over 
automatic type 

UMAP NT35-R

 along with the corresponding accessories. 

The operating instruction must be read carefully before use and kept on the device for direct use! 

1.2

 

Target group 

Only our authorised partners and people who have been trained in the device functions are permitted to 
work on the device, provided that they have read and understood these Operating Instructions. 

Electrical connection work may only be carried out by appropriately trained specialists! 

1.3

 

Symbols used 

This document uses the following types of safety notices as well as general notices: 
 

DANGER! 

"DANGER" denotes a safety notice which, if disregarded, may lead to 

serious 

or

 life-threatening injuries, 

or 

serious material damage

 

 

CAUTION! 

"CAUTION"  denotes  a  safety  notice  which,  if  disregarded,  may  lead  to 

injuries,  damage  to  health 

or 

material damage

 
 

ATTENTION! 

"ATTENTION" denotes a safety notice which, if disregarded, may lead to 

material damage

 

 
 

CORROSIVE! 

"Corrosive" denotes a safety notice which, if disregarded when handling chemicals, may lead to 

injuries

 or 

material damage

 
 

ESD SENSITIVE! 

“ESD  SENSITIVE”  denotes  electronic  components  that  may  be  damaged  by  electrostatic  discharges.  The 
generally accepted safety precautions for ESD-sensitive devices must be observed when handling the devices! 
 

NOTICE! 

A notice denotes information which, if disregarded, may lead to 

malfunctions

 
 
 

Tip! 

A "Tip" denotes information that may result in 

improvements in the operating process

 
 
 

Mandatory sign 

Use face protection! 
 

 

Mandatory sign 

Use protective gloves!

 

In accordance with DIN EN 374, protective gloves against chemicals and microorganisms.

 

 
 

Summary of Contents for UMAP NT35-R

Page 1: ...Item No OI No BA SW 017 03 Umschaltautomatik Typ UMAP NT35 R EN docx Language EN Operating and installation instructions Switch Over Automatic Type UMAP NT35 R...

Page 2: ...mmissioning 8 4 4 Description of the control 9 4 5 Replenish consumables 9 5 Maintenance care faults 10 5 1 Device maintenance 10 Open and close the housing 10 5 2 Trouble shooting 10 6 Decommissionin...

Page 3: ...ces as well as general notices DANGER DANGER denotes a safety notice which if disregarded may lead to serious or life threatening injuries or serious material damage CAUTION CAUTION denotes a safety n...

Page 4: ...ar For these we assume a warranty of 1 2 year Our merchandise management programme requires an invoice for each delivery including warranty services When returning a defective component upon review yo...

Page 5: ...and the chemicals intended for the chlorination must be stored in lockable rooms Re Section 3a Para 1 This requirement ensures that chlorination systems and chemicals shall be protected against weath...

Page 6: ...oups Control electronic 2 suction sets with empty indicator foot valve and container cover 3 2 way switchover solenoid valve for switching between containers Figure 1 Switchover solenoid valve Options...

Page 7: ...ic connection data Hose connection for suction lances 4x1 standard Sewer connection recommended At least DN25 Protection class IP44 Operating data Medium temperature Ambient temperature Humidity techn...

Page 8: ...Mount the external dosing pump in a suitable location for example next to the mounting plate c Attach warning and notice signs in accordance with the locally applicable accident prevention regulation...

Page 9: ...er the LED Container 1 goes out Suction continues from Container 2 d Only once Container 2 is empty the system switches back to Container 1 If Container 1 is still empty the dosing is automatically sw...

Page 10: ...following applies for work on electronic components Never plug in or remove connectors unless the power has been deactivated As the person handling the device please discharge yourself electrostatical...

Page 11: ...suction lances until the lines are clean control via the float switches 4 Disconnect the device from the power supply ATTENTION When recommissioning observe the instructions in the Commissioning chap...

Page 12: ...Switch Over Automatic type UMAP NT35 R Index 03 Date modified 28 03 2022 OI No BA SW 017 03 Umschaltautomatik Typ UMAP NT35 R EN docx Page 12 of 14 7 Documents 7 1 Declaration of conformity...

Page 13: ...Page 13 of 14 7 2 Wiring diagrams DANGER Risk of death due to high voltage All electrical work on the device must only be carried out by trained specialists in accordance with the applicable safety re...

Page 14: ...0 Ribbon cable 10 pole L 300 mm 19541 Bulkhead connector PP 4x1 on both sides 11003 Union nut d 6 PP 1 4 15077 Hose PVC transparent 4 0x1 0 mm 12252 Suction lance NF d16 500 4x1 with empty switch thre...

Reviews: