Switch-Over Automatic, type UMAP NT35-R

 

 

 

Index: 03 

Date modified: 28/03/2022 

OI No.: BA SW 017-03 Umschaltautomatik Typ UMAP NT35-R EN.docx 

Page 2 of 14

 

Table of contents 

1

 

About these instructions / general .......................................................................................................... 3

 

1.1

 

Scope of applicability ........................................................................................................................................ 3

 

1.2

 

Target group .................................................................................................................................................... 3

 

1.3

 

Symbols used ................................................................................................................................................... 3

 

1.4

 

Warranty ......................................................................................................................................................... 4

 

1.5

 

Further information .......................................................................................................................................... 4

 

1.6

 

Information regarding support queries ............................................................................................................. 4

 

2

 

Safety ...................................................................................................................................................... 5

 

2.1

 

Intended use ..................................................................................................................................................... 5

 

2.2

 

Safety notices ................................................................................................................................................... 5

 

 

Handling of chemicals, risks to humans and the environment ........................................................................ 5

 

 

Protective measures and rules of conduct ..................................................................................................... 5

 

3

 

Product description – Functional description – (scope of delivery) .......................................................... 6

 

3.1

 

Scope of delivery / accessories......................................................................................................................... 6

 

3.2

 

Product description - Function.......................................................................................................................... 6

 

3.3

 

Identification of the device / identification plate ............................................................................................... 7

 

3.4

 

Technical data .................................................................................................................................................. 7

 

3.5

 

Transport / storage ......................................................................................................................................... 7

 

4

 

Installation / Commissioning / Operation ............................................................................................... 8

 

4.1

 

Select the installation site .................................................................................................................................. 8

 

4.2

 

Installation instructions / installation ................................................................................................................. 8

 

4.3

 

Commissioning ................................................................................................................................................. 8

 

4.4

 

Description of the control ................................................................................................................................ 9

 

4.5

 

Replenish consumables ..................................................................................................................................... 9

 

5

 

Maintenance, care, faults ....................................................................................................................... 10

 

5.1

 

Device maintenance ....................................................................................................................................... 10

 

 

Open and close the housing......................................................................................................................... 10

 

5.2

 

Trouble-shooting ............................................................................................................................................ 10

 

6

 

Decommissioning – Storage – Disposal ................................................................................................. 11

 

6.1

 

General .......................................................................................................................................................... 11

 

6.2

 

Decommissioning of the switch-over automatic .............................................................................................. 11

 

6.3

 

Disposal of used parts and operating materials ............................................................................................... 11

 

7

 

Documents ............................................................................................................................................ 12

 

7.1

 

Declaration of conformity .............................................................................................................................. 12

 

7.2

 

Wiring diagrams ............................................................................................................................................. 13

 

7.3

 

Spare part list ................................................................................................................................................. 13

 

8

 

Appendices ............................................................................................................................................ 14

 

 
Imprint: 

All rights reserved 

© Copyright by WDT – Werner Dosiertechnik GmbH & Co KG 
Edition: see footer 
Reproduction  of  any  kind  and  translation  into  other  languages,  even  in  excerpts,  are  only  permitted  with  the  express 
authorisation of the company WDT - Werner Dosiertechnik GmbH & Co. KG. Subject to technical modifications 

These operating instructions are an English translation of the original German version by the company WDT. 
 
Responsible for the content:  
Co. WDT - Werner Dosiertechnik GmbH & Co. KG 

Hettlinger Str. 17; 

D-86637 Wertingen-Geratshofen 

Phone: +49 (0) 82 72 / 9 86 97 – 0  Fax: +49 (0) 82 72 / 9 86 97 – 19 

 

Email: 

[email protected]

 

Summary of Contents for UMAP NT35-R

Page 1: ...Item No OI No BA SW 017 03 Umschaltautomatik Typ UMAP NT35 R EN docx Language EN Operating and installation instructions Switch Over Automatic Type UMAP NT35 R...

Page 2: ...mmissioning 8 4 4 Description of the control 9 4 5 Replenish consumables 9 5 Maintenance care faults 10 5 1 Device maintenance 10 Open and close the housing 10 5 2 Trouble shooting 10 6 Decommissionin...

Page 3: ...ces as well as general notices DANGER DANGER denotes a safety notice which if disregarded may lead to serious or life threatening injuries or serious material damage CAUTION CAUTION denotes a safety n...

Page 4: ...ar For these we assume a warranty of 1 2 year Our merchandise management programme requires an invoice for each delivery including warranty services When returning a defective component upon review yo...

Page 5: ...and the chemicals intended for the chlorination must be stored in lockable rooms Re Section 3a Para 1 This requirement ensures that chlorination systems and chemicals shall be protected against weath...

Page 6: ...oups Control electronic 2 suction sets with empty indicator foot valve and container cover 3 2 way switchover solenoid valve for switching between containers Figure 1 Switchover solenoid valve Options...

Page 7: ...ic connection data Hose connection for suction lances 4x1 standard Sewer connection recommended At least DN25 Protection class IP44 Operating data Medium temperature Ambient temperature Humidity techn...

Page 8: ...Mount the external dosing pump in a suitable location for example next to the mounting plate c Attach warning and notice signs in accordance with the locally applicable accident prevention regulation...

Page 9: ...er the LED Container 1 goes out Suction continues from Container 2 d Only once Container 2 is empty the system switches back to Container 1 If Container 1 is still empty the dosing is automatically sw...

Page 10: ...following applies for work on electronic components Never plug in or remove connectors unless the power has been deactivated As the person handling the device please discharge yourself electrostatical...

Page 11: ...suction lances until the lines are clean control via the float switches 4 Disconnect the device from the power supply ATTENTION When recommissioning observe the instructions in the Commissioning chap...

Page 12: ...Switch Over Automatic type UMAP NT35 R Index 03 Date modified 28 03 2022 OI No BA SW 017 03 Umschaltautomatik Typ UMAP NT35 R EN docx Page 12 of 14 7 Documents 7 1 Declaration of conformity...

Page 13: ...Page 13 of 14 7 2 Wiring diagrams DANGER Risk of death due to high voltage All electrical work on the device must only be carried out by trained specialists in accordance with the applicable safety re...

Page 14: ...0 Ribbon cable 10 pole L 300 mm 19541 Bulkhead connector PP 4x1 on both sides 11003 Union nut d 6 PP 1 4 15077 Hose PVC transparent 4 0x1 0 mm 12252 Suction lance NF d16 500 4x1 with empty switch thre...