ADHERE STRICTLY TO THESE
AND ALL OTHER SAFETY
INSTRUCTIONS AND GUIDELINES
· Ensure a barrel blocking device is fitted
to the ANGEL.
· Ensure the hopper is removed from
the ANGEL.
· Ensure that there are no paintballs
in the ANGEL.
· Always remove the first stage regulator and
release all residual gas pressure from the
Angel before disassembly.
· The Angel can hold a small residual gas
charge, typically two shots, with the first stage
regulator removed. Always discharge the Angel
in a safe direction to relieve this residual gas
pressure.
· SHOULD YOU BE UNSURE AT ANY STAGE YOU
MUST SEEK EXPERT ADVICE.
LPR adjustment
The low pressure regulator controls the pneumatic
cycle of the Angel and is located in the left hand
chamber at the rear of the Angel body.
The pressure needs to be at approximately 65psi
(4.5bar) output from an input pressure of 350psi
from the second stage regulator.
LPR adjustment is achieved by the addition or
removal of shims. Each shim equals approximately
2psi (0.14bar) we recommend the use of the optional
service tools and lubrication of parts with LOVE JUICE
extreme grease only.
•
Ensure that the Angel is de-gassed and
switched off.
•
Remove the back plate
using a suitable
2mm Allen key.
•
Remove the LPR chamber plug
using a suitable
4mm Allen key.
•
Insert the optional pressure gauge adaptor into the
hole that the chamber plug was removed from.
•
Re gas the Angel and press the navigation switch
to turn the Angel on.
ADHERE STRICTLY TO THESE
AND ALL OTHER SAFETY
INSTRUCTIONS AND
GUIDELINES
· THE ANGEL IS LIVE AND CAPABLE OF DISCHARGING.
•
Fire 6 shots with NO paintballs present to stabilize
the LPR pressure.
ADHERE STRICTLY TO THESE
AND ALL OTHER SAFETY
INSTRUCTIONS AND
GUIDELINES
· Always remove the first stage regulator and release all
residual gas pressure from the Angel before disassembly.
· The Angel can hold a small residual gas charge, typically
two shots, with the first stage regulator removed. Always
discharge the Angel in a safe direction to relieve this
residual gas pressure.
Note the pressure reading. Should the reading
be too high or low proceed to the next stage.
Ensure that the Angel is de-gassed
and switched off
•
Remove the pressure gauge adaptor and insert
the piston extracting
tool into the piston
and
withdraw it slowly.
•
Remove the 3 tri-active piston springs
.
•
Add or subtract shims
as necessary, note that
the number of shims may vary from the diagram
shown.
•
Replace the 3 tri active springs
in correct order
onto the piston.
•
Re insert the piston
ensuring that it is located
correctly.
•
Insert the optional pressure gauge adaptor into the
hole that the end cap was removed from.
•
Re gas the Angel and press the navigation switch
to turn the Angel on.
ADHERE STRICTLY TO THESE
AND ALL OTHER SAFETY
INSTRUCTIONS AND
GUIDELINES
· THE ANGEL IS LIVE AND CAPABLE OF DISCHARGING.
•
Verify the LPR pressure by following the procedure
described above. Once the desired pressure has
been achieved proceed to the next stage.
ADHERE STRICTLY TO THESE
AND ALL OTHER SAFETY
INSTRUCTIONS AND
GUIDELINES
· Always remove the first stage regulator and release all
residual gas pressure from the Angel before disassembly.
· The Angel can hold a small residual gas charge, typically
two shots, with the first stage regulator removed. Always
discharge the Angel in a safe direction to relieve this
residual gas pressure.
•
Ensure the Angel is de-gassed and switched off.
•
Remove the pressure gauge adaptor and replace
the LPR chamber plug
.
SPRING
STACK
ORDER