Wayne WLS100 Operating Instructions And Parts Manual Download Page 3

parts. Disconnect power sources before 
touching internal parts. See Figure 6 for 
appropriate wiring locations.

Operation

 

NEVER run the 

pump  

  dry. Running pump 

without water may cause seal damage. 
Fill the pump with water before 
starting.

PRIMING THE PUMP

After pump installation is complete, the 
pump must be primed. Remove the pipe 
plug in the discharge piping and fill the 
pump and suction pipe with clean water. 
Turn power to pump on. If  the pump 
does not pump water in 10 minutes, turn 
off the pump and refill with clean water.
If the pump does not operate after 
repeated attempts, check the following:
1.  Vertical distance of pump to water 

level must not be over 25 feet.

2.  Suction piping must be air tight.
3.  Be sure valve(s) are open if used in 

discharge or suction piping.

 

NEVER run the 

pump  

  with a closed or 

clogged discharge. The water inside the 
pump could boil and damage the pump.

Maintenance

Maintain adequate ventilation for the 
pump motor. The motor bearings are 
permanently lubricated at the factory. 
Additional lubrication is not required.

DRAINING FOR WINTER

Always protect pump and piping against 
freezing temperatures. If there is any 
danger of freezing, drain the system. To 
drain the system:
1.   Remove the pipe plug from the 

discharge tee.

2.   Remove the 1/4” plug from the lower 

front face of the pump.

3.   Drain all piping below the frost line.

3

Operating Instructions and Parts Manual 

around the inlet pipe to prevent the 
entrapment of swimmers.

Electrical Connections

Connect the pump to a separate electrical 
circuit with a dedicated circuit breaker. 
Refer to the electrical specifications in 
wiring chart for recommended fuse and 
wire size.
Install and maintain wiring for this pump in 
accordance with the National Electrical 
code and all applicable local electrical 
codes. 
The motor must be grounded by 
connecting a copper conductor to the 
grounding screw provided within the 
wiring compartment.
The voltage of power supply must match 
the voltage of the pump. The WLS75, 
WLS100 and WLS150 have dual voltage 
motors preset at the factory to 230 volts. 
The motors can be converted to 115 volts 
by turning the voltage selector to the 
desired voltage (See Figure 5). Use a 
needle nose pliers to pull the selector out 
approximately 1/4”, rotate and then reinsert 
in correct position. 

NOTE: The WLS200 

cannot be converted; the motor is 
230 volts only

.

CONNECTING WIRES

Terminal cover must be in place for safe 
operation. Ground in accordance with local 
and national electrical codes. Keep fingers 
and objects away from openings and rotating 

www.waynepumps.com

WLS Series

Head 

(ft)

Pressure (psi)

15

20

25

30

5

--

5300

4800

4200

10

--

5100

4500

3950

15

5300

4850

4250

3750

20

5150

4550

4000

3450

25

4850

4300

3750

3100

WLS200 - GPH

Head 

(ft)

Pressure (psi)

15

20

25

30

5

4350

3950

3400

2950

10

4200

3700

3200

2750

15

3950

3450

3000

2500

20

3700

3250

2800

2150

25

3500

3050

2550

1700

WLS150 - GPH

Head 

(ft)

Pressure (psi)

15

20

25

30

5

3650

3200

2800

2450

10

3450

3000

2650

2200

15

3250

2850

2450

1950

20

3050

2650

2300

1600

25

2850

2500

2050

1150

WLS100 - GPH

Head 

(ft)

Pressure (psi)

15

20

25

30

5

3100

2700

2350

1950

10

2900

2550

2200

1700

15

2750

2400

2000

1400

20

2600

2200

1750

1000

25

2450

2050

1450

500

WLS75 - GPH

Figure 5 - Voltage Selector

Figure 6 - Connecting Wire

GROUND 
SCREW

TERMINAL 
BOARD (L2)

Summary of Contents for WLS100

Page 1: ...e electrical circuit checked by an electrician to ensure proper grounding 4 BE CERTAIN the pump power source is disconnected before installing servicing or maintaining the pump 5 Check motor voltage setting on motor end plate and make sure the line voltage of the electrical current supply is correct see figure 5 on page 3 6 Be sure the water source and piping is clear of sand dirt and scale Debris...

Page 2: ... and plug above the well seal is recommended DRIVEN WELL Drive the point several feet below the water table NOTE A packer type foot valve can be installed in the well See Figure 3 This type of foot valve allows the well pipe to be filled with water when priming and makes the inlet pipe much easier to test for leaks Follow the manufacturer s instructions when installing the packer type foot valve A...

Page 3: ...ated circuit breaker Refer to the electrical specifications in wiring chart for recommended fuse and wire size Install and maintain wiring for this pump in accordance with the National Electrical code and all applicable local electrical codes The motor must be grounded by connecting a copper conductor to the grounding screw provided within the wiring compartment The voltage of power supply must ma...

Page 4: ...Feet of Plastic Pipe Pipe Gallons Per Hour Size 1200 1500 1800 2400 3000 3600 4800 6000 7200 WLS75 3 4 120 15 0 25 12 10 8 240 7 5 15 14 14 12 WLS100 1 120 15 0 25 12 10 8 240 7 5 15 14 14 12 WLS150 1 1 2 120 18 0 30 10 10 8 240 9 5 15 14 14 12 WLS200 2 240 11 5 20 14 14 12 Distance in Feet From Motor to Supply Dual 0 51 101 Element 50 100 200 Model HP Volts Amps Fuse 250V AWG Wire Size WIRING CHA...

Page 5: ...ump in new installation did not pick up prime through a Improper priming b Air leaks c Leaking foot valve 2 Pump has lost prime through a air leaks b water level below suction of pump 3 Impeller obstructed 4 Check valve or foot valve is stuck in closed position 5 Pipes are frozen 6 Foot valve and or strainer are buried in sand or mud 7 Low line voltage 1 New installation a Re prime according to in...

Page 6: ... 001 19013 001 19013 001 1 9 Volute 41010 001 41010 001 41010 001 41010 001 1 10 7 16 16 x 1 25 Hex cap screw 67018 001 67018 001 67018 001 67018 001 4 11 1 4 NPT Sq hd pipe plug 16314 002 16314 002 16314 002 16314 002 1 For Replacement Parts or Technical Assistance call 1 800 237 0987 Please provide following information Model number Serial number if any Part description and number as shown in pa...

Page 7: ...Operating Instructions and Parts Manual 7 www waynepumps com WLS Series Notes ...

Page 8: ...LUDED Some states do not allow limitations on how long an implied warranty lasts or do not allow the exclusions or limitations of inci dental or consequential damages so the above lim i ta tions might not apply to you This limited war ran ty gives you specific legal rights and you may also have other legal rights which vary from state to state In no event whether as a result of breach of contract ...

Page 9: ...ncteur de fuite à la terre DDFT 3 Avant l installation de ce produit faire inspecter le circuit électrique par un électricien afin d assurer la mise à la terre correcte 4 S ASSURER que la source d alimentation de la pompe est débranchée avant toute installation entretien ou réparation de la pompe 5 Vérifier le réglage de tension de moteur sur la plaque d extrémité du moteur et s assurer que la ten...

Page 10: ...d sur la première section de tuyau Voir Figure 2 2 Faire baisser le tuyau dans le puits 3 Ajouter de la tuyauterie jusqu à ce que le clapet de pied soit 3 mètres sous le niveau d eau le plus bas prévu Des joints ou des raccords qui fuient permettront à l air de s infiltrer dans le tuyau et induiront un fonctionnement inefficace de la pompe ou des difficultés d amorçage Assurez vous d utiliser de l...

Page 11: ...nvenables Des joints ou des raccords qui fuient permettront à l air de s infiltrer dans le tuyau et induiront un fonctionnement inefficace de la pompe ou des difficultés d amorçage Assurez vous d utiliser de la pâte à joint ou du ruban d étanchéité de plombier sur tous les raccords de tuyauterie filetés Installation Pour Puits Creusés Réservoirs Lacs Et Sources Installer un clapet de pied sur le t...

Page 12: ...ge aux joints Remplir la pompe avec de l eau avant le démarrage AMORÇAGE DE LA POMPE Une fois que l installation soit complète la pompe doit être amorcée Enlever le bouchon mâle de tuyau dans la tuyauterie de décharge et remplir la pompe et le tuyau d aspiration avec de l eau propre Mettre la pompe en marche Si la pompe ne pompe pas d eau dans 10 minutes couper la pompe et remplir à nouveau avec d...

Page 13: ...u d amorçage 1 La pompe dans la nouvelle installation ne s est pas amorcée à cause de a L amorçage incorrect b Fuites d air c Fuite de clapet de pied 2 La pompe a perdue son amorçage à cause de a fuites d air b niveau d eau sous le niveau d aspiration de la pompe 3 Turbine obstruée 4 Vérifier si le clapet ou le clapet de pied est pris dans la position fermée 5 Tuyaux congelés 6 Clapet de pied et o...

Page 14: ... 001 19013 001 19013 001 1 9 Volute 41010 001 41010 001 41010 001 41010 001 1 10 Vis d assemblage hex 7 16 16 x 1 25 po 67018 001 67018 001 67018 001 67018 001 4 11 Bouchon mâle de tuyau à t carré 1 4 po NPT 16314 002 16314 002 16314 002 16314 002 1 Pour Pièces de Rechange ou L assistance Technique Composer 1 800 237 0987 S il vous plaît fournir l information suivante Numéro de Modèle Numéro de Sé...

Page 15: ...Instructions d Utilisation et Manuel de Pièces de Rechange 15 Fr Série WLS Notes ...

Page 16: ...ovinces n autorisent pas de limitations de durée pour les garanties implicites ni l exclusion ni la limitation des dom mages fortuits ou indirects Les limitations précédentes peuvent donc ne pas s appliquer Cette garantie limitée donne à l acheteur des droits légales précis et vous pouvez avoir autres droits légales qui sont variable d une Province ou d un État à l autre En aucun cas soit par suit...

Page 17: ... esta bomba un electricista calificado debe chequear el circuito eléctrico para verificar que esté conectado a tierra adecuadamente 4 CERCIORESE de que la fuente de energía de la bomba esté desconectada antes de instalar realizar servicio o mantener la bomba 5 Chequée el voltaje indicado en la placa del motor y cerciórese de que el voltaje de la corriente eléctrica sea el adecuado consulte la figu...

Page 18: ...e pie en la primera sección de la tubería vea la Figura 2 2 Coloque la tubería dentro del pozo 3 Añada tubos hasta que la válvula de pie esté a 3 05 metros por debajo del nivel de agua más bajo anticipado Las juntas o acoples con pérdidas dejarán que el aire se fugue hacia la tubería y cause un mal funcionamiento de la bomba o dificultad para cebar Asegúrese de usar un compuesto para juntas de tub...

Page 19: ...necciones Eléctricas Conecte la bomba a un circuito eléctrico independiente con un disyuntor dedicado Consulte las especificaciones eléctricas de la tabla de cableado para ver el tamaño recomendado de fusible y del cable Instale y mantenga el sistema eléctrico de esta bomba según los códigos nacionales y locales al respecto El motor se debe conectar a tierra con un conductor de cobre conectado al ...

Page 20: ...alar la bomba deberá cebarla Quítele el tapón a la tubería de descarga y llene la bomba y la tubería de succión de agua limpia Encienda la bomba Si la bomba no comienza a bombear agua en 10 minutos apáguela y llénela de agua limpia una vez más Si la bomba no funciona después de varios intentos chequée lo siguiente 1 La distancia vertical entre la bomba y el nivel de agua no debe ser más de 7 6 met...

Page 21: ... diferente la bomba no completó el proceso de cebado debido a a Cebado incorrecto b Fugas de aire c Fugas en la válvula de pie 2 La bomba perdió el cebado debido a a Fugas de aire b El nivel de agua inferior a la distancia de succión de la bomba 3 La propela está obstruída 4 La válvula de chequeo o la válvula de pie están atascadas en la posición cerrada 5 Las tuberías están congeladas 6 La válvul...

Page 22: ...1 67017 001 67017 001 3 8 Anillo cuadrado 19013 001 19013 001 19013 001 19013 001 1 9 Voluta 41010 001 41010 001 41010 001 41010 001 1 10 Tornillo Hex de 11 1 mm 7 16 16 x 3 2 cm 1 25 67018 001 67018 001 67018 001 67018 001 4 11 Tapón de 6 4 mm 1 4 NPT 16314 002 16314 002 16314 002 16314 002 1 Para Ordenar Repuestos Asistencia Técnica Comuníquese con el Distribuidor Más Cercano a su Domicilio Sírv...

Page 23: ...23 Sp Notas Manual de Instrucciones y Lista de Repuestos Serie WLS ...

Page 24: ...estados no permiten que se establezcan límites en la duración de las garantías implicitas o no permiten que se excluyan ni se establezcan límites en los daños por incidentes o consecuencias por lo tanto los límites antes mencionados podrían ser no válidos Esta Garantía Limitada le otorga derechos legales especificos y usted también puede tener otros derechos que varian de un Estado a otro En ningú...

Reviews: