background image

Lawn Sprinkler 

Pump

© 2014, WAYNE/Scott Fetzer Company.

Description

This pump is a high capacity, centrifugal 
pump suitable for lawn sprinkling or other 
applications where large quantities of 
water are required. Flammable liquids 
such as gasoline, chemicals or corrosive 
liquids should NEVER be used with this 
pump. Use to pump clear water ONLY.

Safety Guidelines

This manual contains information that is 
very important to know and understand. 
This information is provided for SAFETY 
and to PREVENT 
EQUIPMENT PROBLEMS. To help 
recognize this information, observe the 
following symbols. 

 

DANGER indicates  

  an imminently 

hazardous situation which, if NOT 
avoided, WILL result in death or serious 
injury.
 

WARNING indicates 

  a potentially 

hazardous situation which, if NOT 
avoided, COULD result in death or 
serious injury.
 

CAUTION indicates  

  a potentially 

hazardous situation which, if NOT 
avoided, MAY result in minor or 
moderate injury.
 

NOTICE indicates  

 important 

information, that if NOT followed, MAY 
cause damage to equipment.

General Safety 

Information

CALIFORNIA PROPOSITION 65

 

This product or its 

  power cord may 

contain chemicals, including lead, known 
to the State of California to cause cancer 
and birth defects or other reproductive 
harm. Wash hands after handling.

GENERAL SAFETY INFORMATION

  Operating Instructions and Parts Manual 

WLS Series

1.  Read these rules and instructions carefully. 

Failure to follow these 
instructions COULD cause 
serious bodily injury and/or 
property damage.

 

Risk of electrical  

  shock. This pump is 

non-submersible.
 Pump 

  only clear 

water. Do NOT pump flammable 
or explosive fluids such as 
gasoline, fuel oil, kerosene, 
etc. Do NOT use in a flammable 
and/or explosive atmosphere. Personal 
injury and/or property damage WILL result.
 

This pump is NOT  

  designed to handle 

salt water, brine, laundry discharge 
or any other application which may 
contain caustic chemicals and/or 
foreign materials. Pump damage COULD 
occur if used in these applications and 
will void warranty.
 All 

 

 wiring 

must be performed by a 
qualified electrician. The 
pump must be installed in 
compliance with all local and 
national codes.

2.  Connect this product to a grounded 

circuit equipped with a ground fault 
circuit interruptor (GFCI) device.

3.  Before installing this product, have the 

electrical circuit checked by an 
electrician to ensure proper grounding.

4.  BE CERTAIN the pump power source 

is disconnected before installing, 
servicing, or maintaining 
the pump.

5.  Check motor voltage 

setting on motor end plate 
and make sure the line 
voltage of the electrical current supply 
is correct (see figure 5 on page 3).

6.  Be sure the water source and piping is 

clear of sand, dirt and scale. Debris 
WILL clog pump and WILL void 

3202 

04

 -001   9/15

warranty.

7.  Failure to protect pump and piping 

from freezing COULD cause severe 
damage and WILL void the warranty.

8. Do NOT run pump dry. Follow priming 

instructions.

 

Pump motor is  

  equipped with an 

automatic resetting thermal protector 
and may restart unexpectedly. Protector 
tripping is an indication of motor 
overheating because of operating pump 
at low heads (low discharge restriction), 
excessively high or low voltage, 
inadequate wiring, incorrect motor 
connections, excessive surrounding air 
temperature, inadequate ventilation, 
and/or defective motor or pump.

Installation

Protect pump from the elements by 
installing in a basement, garage, tool shed 
or pump house.  Install the pump so the 
center line of the pump is as close as 
possible to the water level. Keep 
installation area clear to provide access 
for service and maintenance. Protect the 
pump against flooding and excess 
moisture. 
Make sure the pump has adequate 
ventilation. The surrounding temperature  
should not exceed 100°F (38°C) or 
nuisance tripping of the motor may occur.

PUMP PIPING INSTALLATION

Use new pipe for best results. Galvanized 
or plastic pipe can be used. When using 
galvanized pipe, provide independent 
supports for both suction and discharge 
piping near the pump to avoid strain on 
the pump. Minimize use of elbows and 
fittings to reduce friction loss. Refer to the 
friction loss chart (on page 4) for specific 
information.
Increase diameter of suction or discharge 
piping if length is over 50 feet.

SUCTION PIPING

MANUAL

For parts, product & service information

visit 

www.waynepumps.com

REMINDER: Keep your dated proof of purchase for warranty purposes! 

Attach it to this manual or file it for safekeeping.

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain 
the product described. Protect yourself and others by observing all safety information. Failure to comply with 
instructions could result in personal injury and/or property damage! Retain instructions for future reference.

Summary of Contents for WLS100

Page 1: ...e electrical circuit checked by an electrician to ensure proper grounding 4 BE CERTAIN the pump power source is disconnected before installing servicing or maintaining the pump 5 Check motor voltage setting on motor end plate and make sure the line voltage of the electrical current supply is correct see figure 5 on page 3 6 Be sure the water source and piping is clear of sand dirt and scale Debris...

Page 2: ... and plug above the well seal is recommended DRIVEN WELL Drive the point several feet below the water table NOTE A packer type foot valve can be installed in the well See Figure 3 This type of foot valve allows the well pipe to be filled with water when priming and makes the inlet pipe much easier to test for leaks Follow the manufacturer s instructions when installing the packer type foot valve A...

Page 3: ...ated circuit breaker Refer to the electrical specifications in wiring chart for recommended fuse and wire size Install and maintain wiring for this pump in accordance with the National Electrical code and all applicable local electrical codes The motor must be grounded by connecting a copper conductor to the grounding screw provided within the wiring compartment The voltage of power supply must ma...

Page 4: ...Feet of Plastic Pipe Pipe Gallons Per Hour Size 1200 1500 1800 2400 3000 3600 4800 6000 7200 WLS75 3 4 120 15 0 25 12 10 8 240 7 5 15 14 14 12 WLS100 1 120 15 0 25 12 10 8 240 7 5 15 14 14 12 WLS150 1 1 2 120 18 0 30 10 10 8 240 9 5 15 14 14 12 WLS200 2 240 11 5 20 14 14 12 Distance in Feet From Motor to Supply Dual 0 51 101 Element 50 100 200 Model HP Volts Amps Fuse 250V AWG Wire Size WIRING CHA...

Page 5: ...ump in new installation did not pick up prime through a Improper priming b Air leaks c Leaking foot valve 2 Pump has lost prime through a air leaks b water level below suction of pump 3 Impeller obstructed 4 Check valve or foot valve is stuck in closed position 5 Pipes are frozen 6 Foot valve and or strainer are buried in sand or mud 7 Low line voltage 1 New installation a Re prime according to in...

Page 6: ... 001 19013 001 19013 001 1 9 Volute 41010 001 41010 001 41010 001 41010 001 1 10 7 16 16 x 1 25 Hex cap screw 67018 001 67018 001 67018 001 67018 001 4 11 1 4 NPT Sq hd pipe plug 16314 002 16314 002 16314 002 16314 002 1 For Replacement Parts or Technical Assistance call 1 800 237 0987 Please provide following information Model number Serial number if any Part description and number as shown in pa...

Page 7: ...Operating Instructions and Parts Manual 7 www waynepumps com WLS Series Notes ...

Page 8: ...LUDED Some states do not allow limitations on how long an implied warranty lasts or do not allow the exclusions or limitations of inci dental or consequential damages so the above lim i ta tions might not apply to you This limited war ran ty gives you specific legal rights and you may also have other legal rights which vary from state to state In no event whether as a result of breach of contract ...

Page 9: ...ncteur de fuite à la terre DDFT 3 Avant l installation de ce produit faire inspecter le circuit électrique par un électricien afin d assurer la mise à la terre correcte 4 S ASSURER que la source d alimentation de la pompe est débranchée avant toute installation entretien ou réparation de la pompe 5 Vérifier le réglage de tension de moteur sur la plaque d extrémité du moteur et s assurer que la ten...

Page 10: ...d sur la première section de tuyau Voir Figure 2 2 Faire baisser le tuyau dans le puits 3 Ajouter de la tuyauterie jusqu à ce que le clapet de pied soit 3 mètres sous le niveau d eau le plus bas prévu Des joints ou des raccords qui fuient permettront à l air de s infiltrer dans le tuyau et induiront un fonctionnement inefficace de la pompe ou des difficultés d amorçage Assurez vous d utiliser de l...

Page 11: ...nvenables Des joints ou des raccords qui fuient permettront à l air de s infiltrer dans le tuyau et induiront un fonctionnement inefficace de la pompe ou des difficultés d amorçage Assurez vous d utiliser de la pâte à joint ou du ruban d étanchéité de plombier sur tous les raccords de tuyauterie filetés Installation Pour Puits Creusés Réservoirs Lacs Et Sources Installer un clapet de pied sur le t...

Page 12: ...ge aux joints Remplir la pompe avec de l eau avant le démarrage AMORÇAGE DE LA POMPE Une fois que l installation soit complète la pompe doit être amorcée Enlever le bouchon mâle de tuyau dans la tuyauterie de décharge et remplir la pompe et le tuyau d aspiration avec de l eau propre Mettre la pompe en marche Si la pompe ne pompe pas d eau dans 10 minutes couper la pompe et remplir à nouveau avec d...

Page 13: ...u d amorçage 1 La pompe dans la nouvelle installation ne s est pas amorcée à cause de a L amorçage incorrect b Fuites d air c Fuite de clapet de pied 2 La pompe a perdue son amorçage à cause de a fuites d air b niveau d eau sous le niveau d aspiration de la pompe 3 Turbine obstruée 4 Vérifier si le clapet ou le clapet de pied est pris dans la position fermée 5 Tuyaux congelés 6 Clapet de pied et o...

Page 14: ... 001 19013 001 19013 001 1 9 Volute 41010 001 41010 001 41010 001 41010 001 1 10 Vis d assemblage hex 7 16 16 x 1 25 po 67018 001 67018 001 67018 001 67018 001 4 11 Bouchon mâle de tuyau à t carré 1 4 po NPT 16314 002 16314 002 16314 002 16314 002 1 Pour Pièces de Rechange ou L assistance Technique Composer 1 800 237 0987 S il vous plaît fournir l information suivante Numéro de Modèle Numéro de Sé...

Page 15: ...Instructions d Utilisation et Manuel de Pièces de Rechange 15 Fr Série WLS Notes ...

Page 16: ...ovinces n autorisent pas de limitations de durée pour les garanties implicites ni l exclusion ni la limitation des dom mages fortuits ou indirects Les limitations précédentes peuvent donc ne pas s appliquer Cette garantie limitée donne à l acheteur des droits légales précis et vous pouvez avoir autres droits légales qui sont variable d une Province ou d un État à l autre En aucun cas soit par suit...

Page 17: ... esta bomba un electricista calificado debe chequear el circuito eléctrico para verificar que esté conectado a tierra adecuadamente 4 CERCIORESE de que la fuente de energía de la bomba esté desconectada antes de instalar realizar servicio o mantener la bomba 5 Chequée el voltaje indicado en la placa del motor y cerciórese de que el voltaje de la corriente eléctrica sea el adecuado consulte la figu...

Page 18: ...e pie en la primera sección de la tubería vea la Figura 2 2 Coloque la tubería dentro del pozo 3 Añada tubos hasta que la válvula de pie esté a 3 05 metros por debajo del nivel de agua más bajo anticipado Las juntas o acoples con pérdidas dejarán que el aire se fugue hacia la tubería y cause un mal funcionamiento de la bomba o dificultad para cebar Asegúrese de usar un compuesto para juntas de tub...

Page 19: ...necciones Eléctricas Conecte la bomba a un circuito eléctrico independiente con un disyuntor dedicado Consulte las especificaciones eléctricas de la tabla de cableado para ver el tamaño recomendado de fusible y del cable Instale y mantenga el sistema eléctrico de esta bomba según los códigos nacionales y locales al respecto El motor se debe conectar a tierra con un conductor de cobre conectado al ...

Page 20: ...alar la bomba deberá cebarla Quítele el tapón a la tubería de descarga y llene la bomba y la tubería de succión de agua limpia Encienda la bomba Si la bomba no comienza a bombear agua en 10 minutos apáguela y llénela de agua limpia una vez más Si la bomba no funciona después de varios intentos chequée lo siguiente 1 La distancia vertical entre la bomba y el nivel de agua no debe ser más de 7 6 met...

Page 21: ... diferente la bomba no completó el proceso de cebado debido a a Cebado incorrecto b Fugas de aire c Fugas en la válvula de pie 2 La bomba perdió el cebado debido a a Fugas de aire b El nivel de agua inferior a la distancia de succión de la bomba 3 La propela está obstruída 4 La válvula de chequeo o la válvula de pie están atascadas en la posición cerrada 5 Las tuberías están congeladas 6 La válvul...

Page 22: ...1 67017 001 67017 001 3 8 Anillo cuadrado 19013 001 19013 001 19013 001 19013 001 1 9 Voluta 41010 001 41010 001 41010 001 41010 001 1 10 Tornillo Hex de 11 1 mm 7 16 16 x 3 2 cm 1 25 67018 001 67018 001 67018 001 67018 001 4 11 Tapón de 6 4 mm 1 4 NPT 16314 002 16314 002 16314 002 16314 002 1 Para Ordenar Repuestos Asistencia Técnica Comuníquese con el Distribuidor Más Cercano a su Domicilio Sírv...

Page 23: ...23 Sp Notas Manual de Instrucciones y Lista de Repuestos Serie WLS ...

Page 24: ...estados no permiten que se establezcan límites en la duración de las garantías implicitas o no permiten que se excluyan ni se establezcan límites en los daños por incidentes o consecuencias por lo tanto los límites antes mencionados podrían ser no válidos Esta Garantía Limitada le otorga derechos legales especificos y usted también puede tener otros derechos que varian de un Estado a otro En ningú...

Reviews: