background image

 

Do not pump gasoline or other 

  explosive liquids. Do not operate 

pump where flammable or explosive fumes or gases are 

present as a fire or explosion could result. Pump should only 

be used to pump clear water. Do not run pump dry.

1.  Read all manuals included with this product carefully. Be 

thoroughly familiar with the controls and the proper use 
of the equipment. 

2.   Protect electrical cord from sharp objects, hot surfaces, 

oil and chemicals. Avoid kinking the cord and replace damaged 
cords immediately.

 

This pump has been evaluated for use 

  with water only.

INSTALLATION

Models PC1 and PC2 include a six foot long suction hose, a water 
suction attachment, and a replacement parts kit which includes: impeller, 
gasket, shaft seal, and two motor brushes (PC2 only, brushes are not 
designed to be replaced on PC1). 

 

Always disconnect power source before 

  attempting to install, service, or maintain the 

pump. Never handle a pump with wet hands or when standing on wet or 

damp surface or in water. Fatal electrical shock could occur.

1.   A ground fault circuit interrupter (GFCI) is required for Model PC2.

 

Risk of electrical shock! This pump is supplied 

  with a grounding conductor and grounding type 

attachment plug. A grounded receptacle in conformance with current 

NEC and local codes must be used (See Figure 1). Do not use model PC2, 

115 V Transfer Pump in swimming pool areas. 

2.   Model PC1 operates on 12V DC only. Model PC2 operates on 

115V only. Voltage and current of power supply must match the 
requirements of the pump. Model PC1 has color-coded battery 
clamps for 12V operation. Model PC1 requires 14 amps at 12 VDC.

3.   Never use an extension cord to power this unit.

 

Risk of fatal electrical shock. Never cut off the 

  round grounding prong. Cutting the cord or plug 

will void the warranty and make the pump inoperable.

4.   Use a strainer when pumping from a creek, pond, or source where 

foreign objects may be sucked into the pump. The strainer should 
prevent solids from entering the inlet line.

5.  A regular garden hose may be used as a discharge line.
6.  The inlet or suction hose should not be longer than 15 feet; and the 

vertical distance between the pump and the water level should not 
be any higher than 10 feet. The maximum discharge height is 30 
feet.

7.   At times, an overload due to overheating, low voltage, jammed 

impeller, etc. may shut the pump off. Unplug or turn off the pump 

  

PC1 and PC2 Series

Self-Priming Transfer Pumps

OPERATING INSTRUCTIONS & PARTS MANUAL

READ, UNDERSTAND AND FOLLOW ALL INSTRUCTIONS IN THIS MANUAL - DO NOT DISCARD.  

Failure to follow these instructions could result in property damage, serious injury or death.

For parts, product & service information visit

 www.waynepumps.com

REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.

© 2016,  
WAYNE/Scott Fetzer Company.

1

DESCRIPTION

These self-priming transfer pumps are designed to easily transfer 
water from one point to another. Model PC1, 12 Volt Transfer Pump 
is convenient when normal power is not readily available. Typical 
applications include removing water from pool covers, clogged drains, 
stock tanks, water basins, boats, cisterns, etc. Model PC2, 115 Volt 
Transfer Pump is great for household usage. Typical applications include 
removing water from waterbeds, clogged sinks, basements, etc. Note: 
Do NOT use PC2 in pool areas. The motors on both models PC1 and 
PC2 are non-submersible.

UNPACKING

After unpacking the transfer pump, carefully inspect for any damage that 
may have occurred during transit. Check for loose, missing or damaged 
parts.

SAFETY GUIDELINES

To help recognize this information, observe the following signal words/
hazard classifications.

 

DANGER indicates an imminently hazardous 

  situation which, if NOT avoided, WILL result in 

death or serious injury.

 

WARNING indicates a potentially hazardous 

  situation which, if NOT avoided, COULD result in 

death or serious injury.

 

CAUTION indicates a potentially hazardous 

  situation which, if NOT avoided, MAY result in 

minor or moderate injury.

 

NOTICE indicates important information, that if 

  NOT followed, MAY cause damage to equipment.

This is the safety alert symbol. It is used to alert you to potential 

bodily injury hazards. Obey all safety messages that follow this 

symbol to avoid possible harm.

NOTE: Information that requires special attention.

GENERAL SAFETY INFORMATION

CALIFORNIA PROPOSITION 65

 

This product contains chemicals known to the  

  state of California to cause cancer or birth 

defects or other reproductive harm. California’s Proposition 65 requires 

this warning to be given to customers in the state of California. 

GENERAL SAFETY

 

Do not submerge motor or allow motor to be 

  exposed to water. Personal injury and/or death 

could result. Keep pump and power cords away from liquids. Model PC1 

becomes very hot during operation. 

321209-001 4/16

Summary of Contents for PC1 Series

Page 1: ...may shut the pump off Unplug or turn off the pump PC1 and PC2 Series Self Priming Transfer Pumps OPERATING INSTRUCTIONS PARTS MANUAL READ UNDERSTAND AND FOLLOW ALL INSTRUCTIONS IN THIS MANUAL DO NOT...

Page 2: ...agram below Figure 2 Model PC2 Plug into a 115 Volt AC 3 prong ground type GFCI receptacle IMPORTANT BATTERY INFORMATION Be certain that the area around the batteries is well ventilated Before servici...

Page 3: ...seal leaks it is usually because the pump has handled abrasive liquids If the motor shaft is scored deep grooves the complete pump must be replaced 1 Remove and inspect impeller parts as specified in...

Page 4: ...ime or retain prime after operating 1 Air leak in suction line 1 Repair suction line by tightening inlet connection or replace 2 Impeller blocked 2 Remove blockage 3 Worn seal 3 Replace seal 4 Suction...

Page 5: ...d number as shown in parts list Address parts correspondence to WAYNE Water Systems 101 Production Drive Harrison OH 45030 U S A Figure 3 Replacement Parts Illustration for Self Priming Transfer Pumps...

Page 6: ...PENS ES WHATSOEVER IS EXCLUDED Some states do not allow limitations on how long an implied warranty lasts or do not allow the exclusions or limitations of incidental or consequential damages so the ab...

Page 7: ...FUNCIONAMIENTO Y EZAS DE REPUESTOI LEA ENTIENDA Y SIGA TODAS LAS INSTRUCCIONES DE ESTE MANUAL NO LO DESECHE No seguir estas instrucciones podr a provocar da o a la unidad lesiones graves o la muerte...

Page 8: ...cando la bomba en un lugar seco Modelo PC1 El motor debe estar conectado a una bater a de tractor automotriz o tipo marino completamente cargada para funcionar Conecte la pinza roja en la terminal pos...

Page 9: ...eje del motor est rayado ranuras profundas se deber reemplazar toda la bomba 1 Retire e inspeccione las piezas del impulsor seg n se especifica en las instrucciones de reemplazo del impulsor Reemplac...

Page 10: ...de aire en la l nea de succi n 1 Repare la l nea de succi n ajustando la conexi n de entrada o reempl cela 2 Impulsor bloqueado 2 Elimine la obstrucci n 3 Sello gastado 3 Reemplace el sello 4 Altura d...

Page 11: ...COBILLA SOLAMENTE PC2 ENCHUFE CON CONEXI N A TIERRA EJE ROTACI N ANILLO DE RETENCI N SELLO DEL EJE IMPULSOR PLACA DE LA CUBIERTA EMPAQUE ACCESORIO DE SUCCI N DE AGUA Para Asistencia T cnica visite la...

Page 12: ...CTOS O CONSECUENTES Ciertos estados no permiten limitaciones sobre el per odo de duraci n de las garant as impl citas ni permiten las exclusiones ni limitaciones de los da os incidentales o consecuent...

Reviews: