background image

Operating Instructions and Parts Manual

3

GENERAL SAFETY INFORMATION CONTINUED

1.  Read all manuals included with this product carefully.  

Be thoroughly familiar with the controls and the proper 
use of the equipment. 

2.   Protect electrical cord from sharp objects, hot surfaces, 

oil and chemicals. Avoid kinking the cord. Do not use if 
cord is damaged.

 This pump has been evaluated for use with clear 

water only.

 MISE EN GARDE

 Cette pompe a été évaluée pour être 

utilisée seulement avec de l’eau fraîche.

 INSTALLATION

This model includes a six foot long suction hose, a water suction 
attachment, and a replacement parts kit which includes: impeller, gasket, 
shaft seal and garden hose washer. A vegetable oil product for impeller 
lubrication is needed.

  Always disconnect power source before 

attempting to install, service, or maintain the pump. Never handle a 

pump with wet hands or when standing on wet or damp surface or in 

water. Fatal electrical shock could occur.

  Toujours débrancher le cordon d'alimentation 

avant d'essayer d'installer, de réparer ou de faire l'entretien de la 

pompe. Ne pas manipuler de pompe avec les mains humides ou debout 

sur une surface humide ou mouillée, ou dans l'eau. Ceci pourrait 

occasionner un choc électrique mortel.

1.   PC1 operates on 12 V DC only. Voltage and current of power 

supply must match the requirements of the pump. This pump has 
color-coded battery clamps for 12 V operation. This pump requires 
14 amps at 12 V DC (see Figure 1).

  Risk of fatal electrical shock. Cutting the cord 

or battery terminal clamps will void the warranty and make the pump 

inoperable.

  Risque de choc électrique mortel. Couper le 

cordon ou les bornes de la batterie annulera la garantie et rendra la 

pompe inutilisable.

2.  Use a strainer when pumping from a creek, pond, or source where 

foreign objects may be sucked into the pump. The strainer should 
prevent solids from entering the inlet line.

3.  A regular garden hose may be used as a discharge line.
4.  The inlet or suction hose should not be longer than 15 feet; and the 

vertical distance between the pump and the water level should not 
be any higher than 10 feet. The maximum discharge height is 30 ft.

6.  Motor should never be operated for more than 2 hours 

continuously. Critical heating can occur and might severely damage 
the pump and void warranty.

OPERATION

NOTE: 

Add 1 tablespoon of vegetable oil to both inlet and outlet to 

prime. Attach included 6 foot suction hose to inlet of pump. Attach 
garden hose to outlet of pump. There must be a gasket in place to  
insure that these connections are airtight, otherwise the pump  
will not prime. 

1.  Connect water suction attachment to the open end of inlet hose 

and place below water surface. (Water suction attachment is 
optional.)The water suction attachment is designed to fit the male 
end of a garden hose. Place the water suction attachment as near 
as possible to the middle of the water that is to be pumped. 

2.  Examine the inlet and outlet hoses to insure there are no blockages, 

kinks or bends. 

  Place switch in “OFF” position before 

connecting or disconnecting battery terminal clamps.

  Placer l'interrupteur en position « OFF » avant 

de connecter ou de déconnecter les pinces des bornes de la batterie.

3.  Connect pump to 12 V battery power source, with pump in a dry 

location. Motor must be connected to a fully charged automotive 
tractor or marine type battery to operate. 

4.  Connect the red clamp to the positive (+) type battery terminal. 

Connect the black clamp to the negative (-) type battery terminal. 
See 12V wiring diagram below (Figure 1). 

Summary of Contents for PC1 Series

Page 1: ...d Bronze Hose Fittings Self Priming Transfer Pump www waynepumps com PERFORMANCE Model Volt Discharge Head 0 ft 5 ft 10 ft 15 ft 20 ft 25 ft PC1 12 Gal hr 310 300 265 230 185 145 Please read and save...

Page 2: ...r water from one point to another in a temporary application This Transfer Pump is convenient when normal power is not readily available Typical applications include removing water from pool covers cl...

Page 3: ...nnulera la garantie et rendra la pompe inutilisable 2 Use a strainer when pumping from a creek pond or source where foreign objects may be sucked into the pump The strainer should prevent solids from...

Page 4: ...es lire et suivre les instructions dans tous les manuels d instruction Pour r duire le risque d explosion de batterie suivez les instructions dans ce manuel et celles publi es par le fabricant de la b...

Page 5: ...ge replace the part s 3 Lubricate new impeller with vegetable oil and reinstall by aligning flat on impeller hub with flat on motor shaft 4 Reassemble gasket cover plate and cover plate screws SHAFT S...

Page 6: ...charges on Products or parts submitted for repair or replacement must be paid by purchaser This Limited Warranty is not transferrable This Limited Warranty does not cover Products which have been dama...

Page 7: ...er as shown in parts list Address parts correspondence to WAYNE Water Systems 101 Production Drive Harrison OH 45030 U S A Figure 2 Replacement Parts Illustration for Self Priming Transfer Pumps BATTE...

Page 8: ...8 NOTES...