from repeated, short cycles when it shuts 
off. This time delay feature will allow the 
pump to run 20-25 seconds after the 
switch reaches the off position. 

www.waynepumps.com

 

Operation 

(continued)

 

4.

 

The control box contains a multicolored 
indicator light. When AC power is 
present, the light will indicate the 
charging state, and not reflect actual 
battery voltage, particularly with a 
defective battery. In order for the 
indicator light to provide an accurate 

reading, steps “a” through “d” must be 

followed. a. Unplug primary AC pump and 
the charger--a power off alert tone will 
sound for 30 seconds. 

b.

 

Lift and release the float switch to 
activate the back-up pump. 

c.

 

When the back-up pump stops, read 
the test light: 

  

  

Green:

 Indicates battery is   

 

charged. 

  

  

Yellow:

 Voltage is low,    

  

indicating battery is partially   

 

charged. 

  

  

Red:

 Battery is completely   

 

discharged or defective. 

d.

 

Plug in charger and main AC pump. 

  

When AC power is out, and when pump 
has been running, the light will indicate 
battery status. 

5.

 

A chirping sound from the control box 
will accompany the red light, indicating 
that the battery may require attention or 
replacement. Voltage is only an indicator 
of battery condition and may not reflect 
the true condition of the battery. See 
Maintenance for instructions on 
assessing battery condition. 

6.

 

A single 30-second tone will sound when 
power to the system is interrupted. The 
unit will reset automatically when power 
is restored. A 3-second tone will sound 
every time the pump starts. 

Maintenance

 

 ALWAYS     

 

disconnect the electrical supply 
before attempting to install, 
service, relocate or perform any 
maintenance. If the power source is out of sight, 
lock and tag in the open (off) position to prevent 
unexpected power application. Failure to do so 
could result in fatal electrical shock. Only qualified 
electricians should repair this unit. Improper repair 
could result in fatal electrical shock.

 

1.

 

Once a month, check battery condition. 

2.

 

Unplug the wall charger. 

3.

 

For batteries with top caps that can be 
removed, the electrolyte level should be 

checked and filled to manufacturer’s 

specifications. The charge for each cell 
should be checked with a hydrometer. A 
specific gravity of 1.265 indicates the 
battery is at full charge. If the specific 
gravity of any of the cells varies more 
than .050, the battery should be 
replaced. 

  

NOTE:

  An inexpensive hydrometer can 

be purchased at an automotive parts 
dealer. 

4.

 

Inspect the terminals and clamps for 
corrosion and tightness. Clean and 
tighten as required. 

5.

 

Unplug the main pump and fill sump 
with water until back-up pump turns on. 
Repeat process two times to be sure 
pump is operating normally. 

6.

 

If pump operates normally, plug charger 
into wall outlet, turn on main pump. If 
pump fails to operate normally, see 
Troubleshooting chart and correct 
problem. Repeat step 5. 

BATTERIES

 

Dangerous hydrogen  

gas can be released 

 

from batteries while charging. Sparks can ignite 
the gas in an enclosed space. Wear safety 
goggles when connecting batteries. Battery 
connections should be made in a well-ventilated 
area.

 

 

Troubleshooting Chart - Back-up Pump

 

Symptom(s)

 

Possible Cause(s)

 

Corrective Action(s)

 

Pump will not run

 

1.

 

Connections not secure

 

2.

 

Low battery

 

3.

 

Float switch obstruction

 

4.

 

Defective or blown fuse 

 

1.

 

Check all connections

 

2.

 

Check battery and replace if low

 

3.

 

Make sure nothing is interfering with the operation of the switch

 

4.

 

Check internal fuse located inside the control box. Pull the charger from the wall outlet 
and remove.  If the fuse is blown, replace it with a 15 amp automotive type fuse

 

Motor hums but 

pump won’t run

 

1.

 

Defective battery

 

2.

 

Obstructed impeller

 

1.

 

Check battery and replace if low or defective

 

2.

 

Unplug pump and check to see if impeller is free to turn. If impeller is locked, remove the 4 
screws on the bottom of the pump to release the housing around the impeller. Remove 
the obstruction. Reassemble pump and reconnect

 

Pump runs but 
pumps very little or 
no water

 

1.

 

Check valve missing or improperly 
installed

 

2.

 

Obstruction in discharge pipe

 

3.

 

Pump not rotated 30˚ 

 

4.

 

Pump air locked 

 

 

 

 

 

5.

 

Discharge pipe length and / or height 
exceeds capacity of pump

 

6.

 

Low or defective battery

 

1.

 

Check to make sure a check valve is installed and functioning between primary pump 
discharge and standby sump pump  tee fitting

 

2.

 

Check for obstruction and clear if necessary

 

3.

 

Check that pump is rotated 30˚ in tee fitting in ESP15 Installation section, Figure 3, on page 

2

 

4.

 

The impeller housing has a small hole on its side. This hole must be open for the pump to 
prime. With the pump unplugged, remove the 4 screws on the bottom of the pump to 
release the housing around the impeller. Clean out the hole and replace cover

 

5.

 

If discharge is too high, a separate line may be required with a lower discharge height

 

6.

 

Check battery and replace if low or defective

 

Pump cycles too 
frequently

 

1.  Main  check  valve  located  between  the  1.  Install  check  valve  or  repair  as  required 

discharge of the primary pump and the back-up sump pump tee fitting or the back-up 
sump pump flapper valve not installed or working properly

 

 

 

 

 

 

Summary of Contents for ESP15

Page 1: ... repair or replace Failure to follow this warning COULD result in fatal electrical shock observe the following symbols Do NOT DANGER indicates expose an imminently battery to sparks or flames as hazardous situation which if NOT avoided an explosion or fire COULD WILL result in death or serious injury result WARNING indicates Battery a potentially acid is hazardous situation which if NOT avoided co...

Page 2: ...ACK UP AND PRIMARY PUMP Figure 1 3 Measure and cut discharge pipe so that back up pump is a minimum of 1 in above the main pump This will allow main pump to operate normally see Figure 1 4 Check the fit of the components before permanently attaching Using 354001 001 7 11 Installation ESP15 continued 5 Insert flapper valve into tee Be sure locator tab is in the notch of the tee fitting see Figure 2...

Page 3: ...e bracket into slot on installation top of tee Secure bracket with screw provided Remove top hex nut from 5 Place the pump with the 4 section of switch and slide the cord up and out PVC pipe on a solid level surface in of the way Slip cord through slot in the sump pit on an elevated surface bracket pull threaded stud through 6 Attach a rubber check valve sold separately to the top of the discharge...

Page 4: ...ire ties provided to secure the switch to the discharge pipe Make sure power wires do not interfere with float switch pump inlet or main pump operation Backup pump must not be allowed to run dry Control Box Installation ESP15 ESP25 1 Attach control box to the side of battery box as shown in Figure 7 Place battery in box attach red cable to positive battery post and black cable to negative post Put...

Page 5: ...lamps for corrosion and tightness Clean and tighten as required 5 Unplug the main pump and fill sump with water until back up pump turns on Repeat process two times to be sure pump is operating normally 6 If pump operates normally plug charger into wall outlet turn on main pump If pump fails to operate normally see Troubleshooting chart and correct problem Repeat step 5 BATTERIES Dangerous hydroge...

Page 6: ... battery causing an explosion Follow battery manufacturer s maintenance procedures and schedules Be certain that the area around the batteries is well ventilated Before servicing the batteries blow away gasses by waving a piece of cardboard near the batteries For Replacement Parts call 1 800 237 0987 Please provide following information Model number Serial number if any Part description and number...

Page 7: ...ESP25 THIS IS THE EXCLUSIVE REMEDY AND ANY LIABILITY FOR ANY AND ALL INDIRECT OR CONSEQUENTIAL DAMAGES OR EXPENSES WHATSOEVER IS EXCLUDED Some states do not allow limitations on how long an implied warranty lasts or do not allow the exclusions or limitations of incidental or consequential damages so the above limitations might not apply to you This limited warranty gives you specific legal rights ...

Page 8: ... Toute installation des fils DOIT être effectuée par un électricien qualifié Manque de suivre cet avertissement PEUT résulter en secousse électrique mortelle NE PAS marcher sur un plancher de sous sol trempe ou humide avant de couper l électricité Si la boîte de branchement est dans le sous sol contacter un électricien Enlever la pompe et la réparer ou remplacer Manque de suivre cet avertissement ...

Page 9: ...1 1 4 po ou 1 1 2 po Un clapet Vendu séparément doit être installé entre le T du modèle ESP et la pompe principale voir Figure 1 LAISSER UN ESPACE DE 10 CM 4 PO AU MIN ENTRE LE COUVERCLE DE LA CUVE ET LA POMPE DE SECOURS LAISSER UN ESPACE DE 2 5 CM 1 PO CLAPET AU MINIMUM ENTRE LA POMPE DE SECOURS ET LA POMPE PRINCIPALE Figure 1 3 Mesurer et couper le tuyau de décharge afin que la pompe de sauvegar...

Page 10: ...ulement le débit et la performance de la pompe 3 Couper une section de 1 2 m 4 pi de tuyau rigide de PVC de 3 2 cm 1 1 4 po ou 3 8 cm 1 1 2 po Cimenter un tuyau de 3 8 cm 1 1 2 po à un raccord fileté Cimenter un tuyau de 3 2 cm 1 1 4 po dans le raccord de tuyau Fixer une section de 3 2 cm 1 1 4 po de tuyau à l adaptateur de décharge ESP25 4 Visser sur la décharge de PVC de la pompe Attention de ne...

Page 11: ...on n entravent pas le fonctionnement de l interrupteur à flotteur l entrée de la pompe ou la pompe principale La pompe de secours ne doit pas fonctionner à sec Installation de la boîte de contrôle ESP15 ESP25 1 Fixer la boîte de contrôle au côté de la boîte de batterie tel qu indiqué dans la Figure 7 Placer la batterie dans la boîte brancher le câble rouge à la borne positive de la pile et le câbl...

Page 12: ...atteries Les connexions de batteries doivent se faire dans un endroit bien ventilé Entretien TOUJOURS débrancher la source d électricité avant d essayer d installer de déplacer ou de Guide De Dépannage Pompe de Secours Symptôme s Cause s possible Action s corrective Pompe ne fonctionne pas 1 Raccords ne sont pas sûrs 2 Batterie faible 3 Obstruction de l interrupteur à flotteur 4 Fusible défectueux...

Page 13: ...r le puisard d eau jusqu à ce que la pompe de sauvegarde se met en marche Répéter le procédé deux fois pour s assurer que la pompe fonctionne normalement Si la pompe fonctionne normalement brancher le chargeur dans la prise du mur mettre la pompe principale en marche Si la pompe ne fonctionne pas normalement voir le guide de dépannage et corriger le problème Répéter l étape 5 Pour des pièces de re...

Page 14: ...PARTICULIER SONT LIMITÉES À UN 1 AN DE KA DATE D ACHAT POUR LE SYSTÈME ESP15 ET DEUX 2 ANS DE LA DATE D ACHAT POUR LE SYSTÈME ESP25 CECI EST LA REMÈDE EXCLUSIVE ET N IMPORTE QUELLE RESPONSABILITÉ POUR N IMPORTE QUEL ET TOUT DOMMAGES INDIRECTS OU DÉPENSES QUOI QUE SE SOIT EST EXCLUS Certaines Provinces n autorisent pas de limitations de durée pour les garanties implicites ni l exclusion ni la limit...

Page 15: ...NCIPALE ________________ Nº DU MODÈLE POMPE DE SECOURS ________________ Nº DE SÉRIE POMPE PRINCIPALE ________________ Nº DE SÉRIE POMPE DE SECOURS ________________ DATE D INSTALLATION ________________ FIXER VOTRE FACTURE ICI ...

Page 16: ...jos de electricidad los debe hacer un electricista calificado Si NO sigue estas advertencias PODRÍA electrocutarse Si el piso del sóta NO está húmedo o inundado NO entre hasta que haya desconectado la electricidad Si la caja de fusibles está en el sótano llame a un electricista Desconecte la bomba y repárela o reemplácela Si NO sigue estas advertencias PODRÍA electrocutarse NO exponga la batería a...

Page 17: ...lotador ni la entrada de la bomba Instalación ESP25 La instalación de esta bomba PODRÍA tomarle varias horas Antes de desconectar temporalmente la bomba principal cerciórese de tener un plan para drenar el sumidero en caso de emergencia 1 Desconecte la corriente que va a la bomba principal 2 La bomba debe instalarse utilizando una tubería rígida de PVC de 3 2 cm 1 1 4 pulg ó 3 8 cm 1 1 2 pulg INST...

Page 18: ... Las piedritas o la arena pueden dañar la bomba causando fallas potenciales de la bomba 2 Esta bomba tiene una descarga de 1 1 2 pulg NPT 3 8 cm Si se desea utilizar tubería de descarga de 1 1 4 pulg NPT 3 2 cm será necesario instalar un adaptador Se vende por separado Las tuberías de diámetro más pequeño reducirán el flujo la velocidad y el rendimiento de la bomba 3 Es necesario colocar una válvu...

Page 19: ...o reubicar o darle mantenimiento a la bomba NUNCA toque la bomba para sumideros el motor de la bomba el agua o la tubería de descarga cuando la bomba esté conectada al tomacorrientes NUNCA manipule una bomba o motor de bomba con las manos mojadas o estando parado sobre una superficie mojada o húmeda o sobre el agua PUEDE ocurrir un choque eléctrico de consecuencias fatales Hay riesgo de descarga e...

Page 20: ...Para Piezas de Repuestos Llame al 1 800 237 0987 Sírvase proporcionar la suguiente información Envíe su solicitud de repuestos a la siguiente dirección Número de modelo WAYNE Water Systems Número de serie si tiene 101 Production Drive Descripción y número de repuesto como se muestra en la lista de repuestos Harrison OH 45030 U S A Guía de diagnóstico de averías Bomba de Respaldo Síntoma s Causa s ...

Page 21: ...004 Tornillo caja de control 16119 002 Bomba 58324 001 Interruptor flotante 30033 001 N de Ref Descripción Número de pieza Ctd 4 1 Ménsula 46049 001 1 2 Conexión en T 17233 002 1 3 Compartiemento de batería 23217 001 1 4 Cargador 17220 004 1 5 Caja de control 30209 003 1 6 Tornillo caja de control 16119 002 4 7 Bomba 17218 003 1 8 Válvula de charnela 17216 001 1 ...

Page 22: ...Manual de Instrucciones de Operación y Piezas 22 Sp Notas ...

Page 23: ...23 Sp ESP15 ESP25 Notas ...

Page 24: ...Manual de Instrucciones de Operación y Piezas 24 Sp ...

Page 25: ...accidentes abusos uso inadecuado negligencia instalación inadecuada mantenimiento inadecuado o funcionamiento sin seguir las instrucciones suministradas por escrito por la compañía WAYNE Water Systems NO EXISTE OTRA GARANTÍA EXPRESA LAS GARANTÍAS IMPLÍCITAS INCLUYENDO AQUELLAS DE COMERCIALIZACIÓN Y APTITUD PARA UN PROPÓSITO EN PARTICULAR ESTÁN LIMITADAS A UNO 1 AÑO A PARTIR DE LA FECHA DE COMPRA P...

Page 26: ...ía Ud DEBERA enviar una COPIA del recibo de la tienda junto con el producto o correspondencia Comuníquese con la compañía WAYNE Water Systems 1 800 237 0987 sólo desde EE UU para recibir autorización e instrucciones de como enviar la mercancía NO ENVIE ESTOS DATOS A WAYNE WATER SYSTEMS Conserve esto sólo como datos MODELO NO BOMBA PRIMARIA _____________________ MODELO NO BOMBA DE RESPALDO ________...

Reviews: