background image

INSTALLATION MANUAL

3

PLEASE SEE WWW.WAYNEPUMPS.COM FOR PRODUCT INFORMATION AND INSTALLATION VIDEOS

NEVER HANDLE A PUMP 

or motor with wet hands or when standing 

on a wet or damp floor while the pump is plugged into the power 

supply.

NE JAMAIS MANIPULER UNE POMPE 

ou un moteur de pompe avec 

les mains mouillées ou debout dans l’eau ou sur une surface 

humide.

RISK OF ELECTRIC SHOCK. 

This pump has not been investigated for 

use in swimming pool and marine areas.

RISQUE DE CHOC ÉLECTRIQUE. 

Cette pompe n’a pas fait l’objet 

de vérification pour une utilisation dans les piscines et les aires 

marines.

DO NOT USE TO PUMP FLAMMABLE OR EXPLOSIVE FLUIDS 

such as 

gasoline, fuel oil, kerosene, etc. Do not use in a flammable and/or 

explosive atmosphere. Pump should only be used to pump clear 

water. Personal injury and/or property damage will result and void 

warranty.

NE PAS UTILISER POUR POMPER DES FLUIDES INFLAMMABLES OU 

EXPLOSIFS 

tels que l’essence, le mazout, le kérosène, etc. Ne 

pas utiliser dans un environnement inflammable et/ou explosif. 

La pompe ne doit être utilisée que pour pomper de l’eau claire. 

Des blessures corporelles et/ou des dégâts matériels pourraient 

en résulter.

PUMPS ARE NOT DESIGNED TO TRANSFER WATER INTENDED FOR 

DRINKING. 

Do not use the pump for moving water that will be 

used for potable/drinking water. Pump should only be used in 

applications for which it is designed.

LES POMPES NE SONT PAS CONÇUES POUR L’ACHEMINEMENT 

D’EAU DESTINÉE À LA CONSOMMATION. 

Ne pas utiliser la pompe 

pour transporter de l’eau qui sera utilisée comme de l’eau 

potable/destinée à la consommation. La pompe doit être utilisée 

uniquement dans les applications pour lesquelles elle est conçue.

DO NOT USE AN EXTENSION CORD OR SURGE PROTECTOR.  

Extension 

cords and/or surge protectors could present a safety hazard if not 

sized properly, become damaged or the connection falls into the 

sump.  If receptacle is not within reach of the pump’s power cord, 

contact a qualified licensed electrician to install a new receptacle.

NE PAS UTILISER DE RALLONGE NI DE PROTECTEUR DE SURTENSION. 

Les rallonges et/ou les protecteurs de surtension peuvent présenter 

un danger pour la sécurité s’ils ne sont pas correctement calibrés, 

s’ils sont endommagés ou si le raccordement tombe dans le 

puisard. Si la prise n’est pas à portée du cordon d’alimentation 

de la pompe, contacter un électricien qualifié pour installer une 

nouvelle prise.

CAUTION INDICATES A POTENTIALLY HAZARDOUS SITUATION 

WHICH, IF NOT AVOIDED, MAY RESULT IN MINOR OR 

MODERATE INJURY.

 MISE EN GARDE

LA MENTION MISE EN GARDE INDIQUE UNE SITUATION 

POTENTIELLEMENT DANGEREUSE QUI, SI ELLE N’EST PAS 

ÉVITÉE, POURRAIT ENTRAÎNER DES BLESSURES MINEURES 

OU MODÉRÉES.

TO REDUCE THE RISK OF HAZARDS THAT CAN CAUSE 

INJURY OR PROPERTY DAMAGE, OBSERVE THE FOLLOWING 

WARNINGS:
POUR RÉDUIRE LE RISQUE DE DANGERS POUVANT CAUSER 

DES BLESSURES OU DES DÉGÂTS MATÉRIELS, RESPECTER 

LES MISES EN GARDE SUIVANTES :

IT IS THE INSTALLER’S RESPONSIBILITY TO MAKE SURE THE 

PUMPS AUTOMATIC SWITCH IS ABLE TO OPERATE WITHOUT ANY 

OBSTRUCTIONS WITHIN THE BASIN. 

It is recommended that the 

installer test and observe the pump’s operation for several cycles 

after installation.

IL EST DE LA RESPONSABILITÉ DE L’INSTALLATEUR DE S’ASSURER QUE 

L’INTERRUPTEUR AUTOMATIQUE DE POMPE PEUT FONCTIONNER SANS 

AUCUN BLOCAGE À L’INTÉRIEUR DU SYSTÈME. 

Il est recommandé 

que l’installateur teste et observe le fonctionnement de la pompe 

pendant plusieurs cycles après l’installation.

IT IS REQUIRED TO USE RIGID PIPING AND FITTINGS 

to secure the 

pump in the basin and reduce pump movement.  Pump movement 

can prevent the switch from operating correctly. Do not use flexible 

hosing.

IL EST NÉCESSAIRE D’UTILISER DES TUYAUX ET DES RACCORDS 

RIGIDES 

pour fixer la pompe dans le système et réduire les 

mouvements de la pompe. Les mouvements de la pompe peuvent 

empêcher l’interrupteur de fonctionner correctement. Ne pas 

utiliser de tuyaux flexibles.

IT IS REQUIRED TO USE A CHECK VALVE 

with this pump to prevent the 

back-flow of clear ground water after each pump cycle.
Cette pompe 

NÉCESSITE L’UTILISATION D’UNE VANNE DE CONTRÔLE 

pour empêcher le reflux d’eau souterraine claire après chaque 

cycle de pompage.

DO NOT INSTALL OR OPERATE THE PUMP IF IT HAS BEEN DAMAGED 

IN ANY WAY. 
NE PAS INSTALLER OU FAIRE FONCTIONNER LA POMPE SI ELLE A ÉTÉ 

ENDOMMAGÉE DE QUELQUE MANIÈRE QUE CE SOIT.

DO NOT LIFT OR CARRY THE PUMP BY THE POWER CORD.  

Use the 

pump’s handle or lift ring.

NE PAS SOULEVER OU PORTER LA POMPE PAR LE CORDON 

D’ALIMENTATION. 

Utiliser la poignée ou la bague de levage de la 

pompe.

Summary of Contents for CDU800SS

Page 1: ...by observing all safety information Failure to comply with instructions could result in personal injury and or property damage Retain instructions for future reference Operating Instructions and Parts Manual Sumps Images are for illustration purposes only Not all models are shown CONSTRUCTION MOTOR HOUSING Stainless Steel CDU1000 CDU980E CDU800SS CDU790SS Coated Steel CDU800 CDU790 SPF33 SPF50 CDT...

Page 2: ...res NE JAMAIS RETIRER LE CONNECTEUR DE MISE À LA TERRE de la prise ou contourner les fils de mise à la terre MAKE SURE THE POWER SUPPLY HAS A FUSE OR CIRCUIT BREAKER rated to handle the current amps noted on the pump nameplate or cord tag S ASSURER QUE L ALIMENTATION ÉLECTRIQUE EST MUNIE D UN FUSIBLE OU D UN DISJONCTEUR d une valeur nominale appropriée pour supporter l intensité du courant ampérag...

Page 3: ...magés ou si le raccordement tombe dans le puisard Si la prise n est pas à portée du cordon d alimentation de la pompe contacter un électricien qualifié pour installer une nouvelle prise CAUTION INDICATES A POTENTIALLY HAZARDOUS SITUATION WHICH IF NOT AVOIDED MAY RESULT IN MINOR OR MODERATE INJURY MISE EN GARDE LA MENTION MISE EN GARDE INDIQUE UNE SITUATION POTENTIELLEMENT DANGEREUSE QUI SI ELLE N ...

Page 4: ...ertical n est pas remplaçable This product can expose you to chemicals including DEHP which is known to the State of California to cause cancer birth defects and reproductive harm For more information go to www P65Warnings ca gov Ce produit peut vous exposer à des produits chimiques notamment du DOP reconnus par l État de Californie comme étant cancérigènes et à l origine d anomalies congénitales ...

Page 5: ...ioned in a downward slope away from the foundation so any remaining water will drain away and not freeze 15 Secure the basin cover and gasket to the basin to prevent debris from falling into the basin prevent personal injury and to contain gases and or odors TYPICAL SUMP INSTALLATION 1 This installation must be in accordance with the National Electric Code and all applicable local codes and ordina...

Page 6: ...inadequate wiring incorrect motor conditions or at the end of product life TROUBLESHOOTING CHART Symptoms Possible Cause s Suggested Remedies Pump will not start or run 1 Water level too low 2 Blown fuse or tripped circuit breaker 3 Low supply voltage 4 Motor 5 Switch 6 Inlet screen clogged 7 Switch obstruction 1 Water must be at the appropriate level to activate switch 2 If blown determine cause ...

Page 7: ...Remove debris 3 Replace pump 4 Recheck all sizing calculations to determine proper pump size 5 Remove and examine check valve for proper installation and free operation 6 Open valve ROUTINE SUMP MAINTENANCE The pump should be inspected 3 4 times per year for pump movement or buildup of debris on the switch or float Reposition pump if it has moved Remove any debris that could interfere with the ope...

Page 8: ...INSTALLATION MANUAL AND REPLACEMENT PARTS 8 REPAIR KITS REF NO DESCRIPTION PART NUMBER 1 FLOAT KIT 60038 WYN1 2 TETHER SWITCH 56835 WYN1 2 1 ...

Page 9: ... to operate in accordance with WAYNE s written instructions This Limited Warranty does not cover Products which have been damaged as a result of accident abuse misuse neglect improper installation improper maintenance or failure to operate in accordance with Wayne Water Systems written instructions THIS WARRANTY IS IN LIEU OF ANY AND ALL OTHER WARRANTIES OBLIGATIONS OR AGREEMENTS EXPRESSED OR IMPL...

Reviews: