INSTALLATION MANUAL

2

SAFETY SIGNAL WORDS

This manual contains information that is very important 
to know and understand. This information is provided for 
SAFETY and to PREVENT EQUIPMENT PROBLEMS. To 
help recognize this information, observe all safety information 
labeled danger, warning, caution, and notice. 

SUMP PUMP DESCRIPTION

Sump pumps are automatic pumps used to remove ground 

water from sump pits. The most common application is for 

basement drainage to prevent flooding in residential buildings. 

These sumps are designed to pump clear water only. These 

pumps are not designed to be used with a portable generator. 

Installation of this pump outdoors, unprotected from the 

weather, may cause hazardous conditions and will void warranty. 

Water inside the pump may freeze, limiting its performance and 

damaging the pump and pipes.

UNPACKING

Inspect this unit before it is used. Occasionally, products are damaged 
during shipment. If the pump or components are damaged, return 
the unit to the place of purchase for replacement, or call Customer 
Support (800-237-0987).

Intended for Indoor Use Only

PLEASE SEE WWW.WAYNEPUMPS.COM FOR PRODUCT INFORMATION AND INSTALLATION VIDEOS

This pump is not designed to handle salt water, brine, laundry 

discharge, water softener, sewage, grey water, or any other 

application which may contain caustic chemicals and/or 

foreign materials. Pump and/or property damage could occur  

if used in these applications and will void warranty.

FOR ADDED SAFETY 

the receptacle must be protected with a ground 

fault circuit interrupter (GFCI). All wiring must be performed by a 

qualified licensed electrician and comply with the National Electric 

Code and all applicable local codes and ordinances.

POUR PLUS DE SÉCURITÉ, 

la prise de courant doit être protégée par 

un disjoncteur de fuite à la terre. Tout le câblage doit être effectué 

par un électricien qualifié et être conforme au Code électrique 

national et à tous les codes et règlements locaux applicables.

NEVER REMOVE THE GROUND PRONG 

from the plug or bypass the 

grounding wires.

NE JAMAIS RETIRER LE CONNECTEUR DE MISE À LA TERRE 

de la prise 

ou contourner les fils de mise à la terre.

MAKE SURE THE POWER SUPPLY HAS A FUSE OR CIRCUIT BREAKER 

rated to handle the current (amps) noted on the pump nameplate 

or cord tag.

S’ASSURER QUE L’ALIMENTATION ÉLECTRIQUE EST MUNIE D’UN 

FUSIBLE OU D’UN DISJONCTEUR 

d’une valeur nominale appropriée 

pour supporter l’intensité du courant (ampérage) indiquée sur la 

plaque signalétique ou l’étiquette du cordon de la pompe.

DO NOT REMOVE POWER SUPPLY CORD 

and strain relief or connect 

conduit directly to the pump.

NE PAS RETIRER LE CORDON D’ALIMENTATION ÉLECTRIQUE 

et le 

réducteur de tension, ni connecter le conduit directement à la 

pompe. 

ALWAYS DISCONNECT THE PUMP 

from power supply before installing, 

servicing or making any adjustments.

TOUJOURS METTRE LA POMPE HORS TENSION 

avant de procéder à 

l’installation, à l’entretien ou à des réglages. 

DO NOT WALK 

on the floor when water is present until all power is 

turned off.  If the electric panel is in the basement, call an electrician.

NE PAS MARCHER 

sur un sol mouillé avant que l’alimentation 

générale ne soit coupée. Si le tableau électrique est en sous-sol, 

appeler un électricien.

IMPORTANT SAFETY INFORMATION
CONSIGNES DE SÉCURITÉ 

IMPORTANTES

WARNING INDICATES A POTENTIALLY HAZARDOUS SITUATION 

WHICH, IF NOT AVOIDED, COULD RESULT IN DEATH OR 

SERIOUS INJURY.

LA MENTION AVERTISSEMENT INDIQUE UNE SITUATION 

POTENTIELLEMENT DANGEREUSE QUI, SI ELLE N’EST PAS 

ÉVITÉE, RISQUE D’ENTRAÎNER DES LÉSIONS CORPORELLES 

GRAVES OU MÊME LA MORT.

RISK OF ELECTRIC SHOCK. TO REDUCE THIS RISK, 

OBSERVE THE FOLLOWING WARNINGS:
RISQUE DE CHOC ÉLECTRIQUE. POUR RÉDUIRE CE 

RISQUE, TENIR COMPTE DES AVERTISSEMENTS 

SUIVANTS 

MAKE SURE THERE IS A PROPERLY GROUNDED RECEPTACLE 

AVAILABLE. 

This pump is supplied with a grounding conductor 

and grounding-type attachment plug. To reduce the risk of electric 

shock, be certain that it is connected only to a properly grounded, 

grounding-type receptacle.

S’ASSURER QU’UNE PRISE DE MISE À LA TERRE EST DISPONIBLE. 

Cette pompe est fournie avec un conducteur et une fiche de mise à 

la terre. Pour réduire le risque de choc électrique, s’assurer qu’elle 

est branchée seulement à une prise de courant correctement mise 

à la terre.

Summary of Contents for CDU800SS

Page 1: ...by observing all safety information Failure to comply with instructions could result in personal injury and or property damage Retain instructions for future reference Operating Instructions and Parts Manual Sumps Images are for illustration purposes only Not all models are shown CONSTRUCTION MOTOR HOUSING Stainless Steel CDU1000 CDU980E CDU800SS CDU790SS Coated Steel CDU800 CDU790 SPF33 SPF50 CDT...

Page 2: ...res NE JAMAIS RETIRER LE CONNECTEUR DE MISE À LA TERRE de la prise ou contourner les fils de mise à la terre MAKE SURE THE POWER SUPPLY HAS A FUSE OR CIRCUIT BREAKER rated to handle the current amps noted on the pump nameplate or cord tag S ASSURER QUE L ALIMENTATION ÉLECTRIQUE EST MUNIE D UN FUSIBLE OU D UN DISJONCTEUR d une valeur nominale appropriée pour supporter l intensité du courant ampérag...

Page 3: ...magés ou si le raccordement tombe dans le puisard Si la prise n est pas à portée du cordon d alimentation de la pompe contacter un électricien qualifié pour installer une nouvelle prise CAUTION INDICATES A POTENTIALLY HAZARDOUS SITUATION WHICH IF NOT AVOIDED MAY RESULT IN MINOR OR MODERATE INJURY MISE EN GARDE LA MENTION MISE EN GARDE INDIQUE UNE SITUATION POTENTIELLEMENT DANGEREUSE QUI SI ELLE N ...

Page 4: ...ertical n est pas remplaçable This product can expose you to chemicals including DEHP which is known to the State of California to cause cancer birth defects and reproductive harm For more information go to www P65Warnings ca gov Ce produit peut vous exposer à des produits chimiques notamment du DOP reconnus par l État de Californie comme étant cancérigènes et à l origine d anomalies congénitales ...

Page 5: ...ioned in a downward slope away from the foundation so any remaining water will drain away and not freeze 15 Secure the basin cover and gasket to the basin to prevent debris from falling into the basin prevent personal injury and to contain gases and or odors TYPICAL SUMP INSTALLATION 1 This installation must be in accordance with the National Electric Code and all applicable local codes and ordina...

Page 6: ...inadequate wiring incorrect motor conditions or at the end of product life TROUBLESHOOTING CHART Symptoms Possible Cause s Suggested Remedies Pump will not start or run 1 Water level too low 2 Blown fuse or tripped circuit breaker 3 Low supply voltage 4 Motor 5 Switch 6 Inlet screen clogged 7 Switch obstruction 1 Water must be at the appropriate level to activate switch 2 If blown determine cause ...

Page 7: ...Remove debris 3 Replace pump 4 Recheck all sizing calculations to determine proper pump size 5 Remove and examine check valve for proper installation and free operation 6 Open valve ROUTINE SUMP MAINTENANCE The pump should be inspected 3 4 times per year for pump movement or buildup of debris on the switch or float Reposition pump if it has moved Remove any debris that could interfere with the ope...

Page 8: ...INSTALLATION MANUAL AND REPLACEMENT PARTS 8 REPAIR KITS REF NO DESCRIPTION PART NUMBER 1 FLOAT KIT 60038 WYN1 2 TETHER SWITCH 56835 WYN1 2 1 ...

Page 9: ... to operate in accordance with WAYNE s written instructions This Limited Warranty does not cover Products which have been damaged as a result of accident abuse misuse neglect improper installation improper maintenance or failure to operate in accordance with Wayne Water Systems written instructions THIS WARRANTY IS IN LIEU OF ANY AND ALL OTHER WARRANTIES OBLIGATIONS OR AGREEMENTS EXPRESSED OR IMPL...