background image

REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.

Description

This sewage pump is suitable for
pumping sewage, effluent, wastewater,
groundwater and other nonexplosive,
noncorrosive liquids with up to two inch
solids. The RPP50 pump includes a wide
angle float switch that turns the pump on
and off as the fluid level rises and falls.
The RPPCAP50 is provided with a “Switch
Genius” capacitive water sensor. When
water is detected, the pump will start
automatically. These pumps are intended
for use in domestic sewage lift stations.

Unpacking

Inspect this unit before it is used.
Occasionally, products are damaged
during shipment. If the pump or
components are damaged, return the
unit to the place of purchase for
replacement. Failure to do so could
result in serious injury or death.

Safety Guidelines

This manual contains information that is
very important to know and understand.
This information is provided for SAFETY
and to PREVENT EQUIPMENT PROBLEMS.
To help recognize this information,
observe the following symbols. 

Operating Instructions 

Models RPP50 and RPPCAP50

331301-001  12/07

Danger

indicates

an imminently hazardous situation
which, if not avoided, will result in
death or serious injury.

Warning

indicates

a potentially hazardous situation
which, if not avoided, could result in
death or serious injury.

Caution

indicates

a potentially hazardous situation
which, if not avoided, MAY result in
minor or moderate injury.

Notice
indicates

important information, that if not
followed, may cause damage to
equipment.

General Safety
Information

CALIFORNIA PROPOSITION 65

This

product

or its power cord may contain
chemicals known to the State of
California to cause cancer and birth
defects or other reproductive harm.
Wash hands after handling.

GENERAL SAGETY INFORMATION

1. Know the pump application,

limitations, and po ten tial hazards.

Do not use to pump
flammable or explosive fluids
such as gasoline, fuel oil,
kerosene, etc. Do not use in flammable
and/or explosive atmospheres. Use pump
only with liquids compatible with pump
component materials. Failure to follow
this warning can result in personal
injury and/or property damage.

2. Make certain that the power source

(electric motor) conforms to the
requirements of the equipment.

Disconnect power before
servicing. If the power dis -
con nect is out of sight, lock
in the open po si tion and tag it to
prevent unexpected application of
power. Failure to do so could result in
fatal electrical shock!

3. Release all pressure within the system

before ser vic ing any component.

4. Drain all liquids from the system

before servicing.

This

pump

contains dielectric motor oil for motor
heat transfer. Care should be taken when
disposing of this oil. Do not use this
pump in ponds or fountains because the
motor oil can be harmful to aquatic life.

5. Secure the discharge line before

starting the pump. An unsecured
discharge line will whip, possibly

© 2007 Wayne Water Systems

Specifications

RPP50

RPPCAP50

Power supply requirements

120V, 60 hz

120V, 60 hz

Circuit requirements

15 amps (min)

15 amps (min)

Motor duty

Intermittent

Intermittent

Motor

120V, 1 Phase

120V, 1 Phase

Horsepower 

1/2

1/2

Motor full load

6.3 amps

6.3 amps

Liquid temperature range

40°F to 120°F

40°F to 120°F

Max. operating position

45

o

from vertical

45

o

from vertical

Dimensions

14” x 12”

14” x 12”

Intake

2”

2”

Discharge

2” NPT female

2” NPT female

Cut-in level (factory set)

16”

11”

Cut-out level (factory set)

7.5”

7”

Differential

8.5”

4”

Switch

90

o

wide angle

“Switch Genius”

mechanical tether switch

capacitive water sensor

Power cord

18 gauge 3 Conductor 

18 gauge 3 Conductor

with plug

with plug

Construction

Motor housing.......Cast iron
Volute ....................Cast iron
Impeller...................Glass reinforced PBT
Seal plate ...............Cast Iron
Shaft seal ...............Mechanical

GALLONS PER HOUR AT TOTAL

HEAD IN FEET

0

5

10

15

5700

4560

3240

900

Performance

1/2 HP Cast Iron
Sewage Pump

For parts, product & service information

visit 

www.waynepumps.com

Please read and save these instructions. Read carefully before attempting to assemble, install, operate
or maintain the product described. Protect yourself and others by observing all safety information.
Failure to comply with instructions could result in personal injury and/or property damage! Retain
instructions for future reference.

Summary of Contents for 331301-001

Page 1: ...Use pump only with liquids compatible with pump component materials Failure to follow this warning can result in personal injury and or property damage 2 Make certain that the power source electric m...

Page 2: ...rical Code NEC and the Occupational Safety and Health Act OSHA Risk of electric shock Never connect the green or green and yellow wire to a live terminal 11 This equipment is only for use on 120 volt...

Page 3: ...n cause an electrical shock hazard The pump contains oil that may be under pressure because of heat Let the pump cool for a minimum of two hours before servicing this unit 1 Disassembly of the motor p...

Page 4: ...s top of pump 2 If blown replace with proper sized fuse or reset breaker 3 If voltage is under recommended minimum check wiring size from the main switch on property If OK contact power company 4 Retu...

Page 5: ...he top of the sensor 2 If blown replace with proper sized fuse or reset breaker 3 If voltage is under recommended minimum check wiring size from the main switch on property If OK contact power company...

Page 6: ...SOEVER IS EXCLUDED Some states do not allow limitations on how long an implied warranty lasts or do not allow the exclusions or limitations of incidental or consequential damages so the above limitati...

Page 7: ...e l information importante pour viter le dommage de l quipement G n ralit s sur la S curit PROPOSITION 65 DE CALIFORNIE Ce produit ou son cordon peuvent contenir des produits chimiques qui de l avis d...

Page 8: ...u des d g ts mat riels 6 Inspecter les tuyaux pour tout signe de faiblesse et d usure avant chaque utilisation et v rifier le serrage de tous les branchements 7 Inspecter la pompe et les pi ces d tach...

Page 9: ...e position horizontale ou un angle de 45 avec le pivot de la soupape en haut Dans une position verticale les solides on tendance se d poser sur le volet de la soupape et peuvent l emp cher de s ouvrir...

Page 10: ...heures de proc der l entretien de ce mod le 1 D monter le moteur avant l expiration de la garantie annulera la garantie Il est aussi possible de causer des fuites internes et d endommager le mod le S...

Page 11: ...la taille des fils de l interrupteur g n ral de la propri t Si correcte contacter la compagnie de service publique 4 Retourner pour l entretien ou remplacer le moteur 5 Remplacer l interrupteur flotte...

Page 12: ...taille des fils de l interrupteur g n ral de la propri t Si correcte contacter la compagnie de service publique 4 Retourner pour l entretien ou remplacer le moteur 5 Remplacer le Switch Genius 6 Si la...

Page 13: ...orisent pas de limitations de dur e pour les garanties implicites ni l exclusion ni la limitation des dommages fortuits ou indirects Les limitations pr c dentes peuvent donc ne pas s appliquer Cette g...

Page 14: ...IA la muerte o heridas de gravedad sto le indica que hay una situaci n que PODRIA ocasionarle la muerte o heridas de gravedad sto le indica que hay una situaci n que PODRIA ocasionarle heridas no muy...

Page 15: ...e su alcance apague la unidad con el interruptor y aseg relo de modo que la unidad no pueda encenderse accidentalmente De no hacerlo podr a morir electrocutado 3 Libere toda la presi n del sistema ant...

Page 16: ...cela Si no sigue estas instrucciones podr a morir electrocutado Instalaci n Si hay peligro de que sufra heridas personales o da os a su propiedad si la bomba se da a o tiene fugas debido a interrupci...

Page 17: ...lo los t cnicos electricistas especializados o el personal de los centros de servicio autorizado deben tratar de reparar esta unidad De lo contrario podr a ocasionar peligro de electrocutamiento Esta...

Page 18: ...taje es inferior al m nimo recomendado chequ e el alambrado del circuito principal de la propiedad Si es adecuado comun quese con la compa a de electricidad 4 Envie el motor al centro de servicio auto...

Page 19: ...mo recomendado chequ e el alambrado del circuito principal de la propiedad Si es adecuado comun quese con la compa a de electricidad 4 Envie el motor al centro de servicio autorizado m s cercano a su...

Page 20: ...POR DA OS INDIRECTOS O CONSECUENTES QUEDAN EXCLUIDOS Algunos estados no permiten que se establezcan l mites en la duraci n de las garant as implicitas o no permiten que se excluyan ni se establezcan...

Reviews: