7. Periodically inspect the pump and

system components. Perform
routine maintenance as required
(See Maintenance Section).

8. Provide a means of pressure relief

for pumps whose discharge line can
be shut-off or obstructed.

9. Personal Safety:

a. Wear safety glasses at all times

when working with pumps.

b. Keep work area clean,

uncluttered and properly lighted;
replace all unused tools and
equipment.

c. Keep visitors a safe distance from

the work area. Make workshop
child-proof with padlocks, master
switches, and by removing starter
keys.

10. When wiring an electrically driven

pump such as this, follow all
electrical and safety codes, as well
as the most recent National
Electrical Code (NEC) and the Occu-
pational Safety and Health Act
(OSHA).

Risk of electric shock! Never
connect the green (or green
and yellow) wire to a live
terminal!

11. This equipment is only for use on

120 volt (single-phase) and is
equipped with an approved 3-con-
ductor cord and 3-prong,
grounding-type plug as shown in
Figure 1A & 1B.

To reduce the risk of electric shock, the
motor must be securely and adequately
grounded. This can be accomplished by
the following:

-  Inserting plug directly into a properly

installed and grounded 3-prong,
grounding-type receptacle (as shown
in Figure 1A & 1B ).

Where a 2-prong wall receptacle is
encountered, it must be replaced with
a properly grounded 3-prong recepta-
cle installed in accordance with the NEC
and local codes and ordinances.

12. All wiring should be performed by a

qualified electrician.

13. Always connect this product to a

grounded outlet equipped with a
Ground Fault Circuit Interrupter
(GFCI) device. Consult a local
electrician for installation and
availability.

General Safety
Information

CALIFORNIA PROPOSITION 65

This 

product

or its power cord contains lead, a
chemical known to the State of
California to cause cancer and birth
defects or other reproductive harm.
Wash hands after handling.

GENERAL SAFETY

1. Know the pump application,

limitations, and potential hazards.

Do not use to pump
flammable or explosive fluids
such as gasoline, fuel oil,
kerosene, etc. Do not use in flammable
and/or explosive atmospheres. Use
pump only with liquids compatible with
pump component materials. Failure to
follow this warning can result in
personal injury and/or property
damage.

2. Make certain that the power source

(electric motor) conforms to the
requirements of the equipment.

Disconnect power before
servicing. If the power dis-
connect is out of sight, lock in
the open position and tag it to prevent
unexpected application of power.
Failure to do so could result in fatal
electrical shock!

3. Release all pressure within the

system before servicing any
component.

4. Drain all liquids from the system

before servicing.

This

pump

contains dielectric motor oil for
lubrication and motor heat transfer.
Care should be taken when disposing
of this oil. Do not use this pump in
ponds or fountains because the motor
oil can be harmful to aquatic life.

5. Secure the discharge line before

starting the pump. An unsecured
discharge line will whip, possibly
causing personal injury and/or
property damage.

6. Check hoses for weak and worn

condition before each use, making
certain that all connections are
secure.

2

Operating Instructions and Parts Manual

The

pump

motor is equipped with automatic
resetting thermal protector and may
restart unexpectedly. Protector tripping
is an indication of motor overloading as
a result of operating the pump at low
heads (low discharge restriction),
excessively high or low voltage,
inadequate wiring, incorrect motor
conditions, or a defective motor or
pump.

14. This pump is designed to transfer

water in cycles. Using this pump in a
continuous duty application by
manipulating the switch to stay on,
will effect the performance and the
life of the product.

15. Protect electrical cord from sharp

objects, hot surfaces, oil, and
chemicals. Avoid kinking the cord.
Replace or repair damaged or worn
cords immediately. Use wire of
adequate size to minimize voltage
drop at the motor.

16. Do not handle a pump or pump

motor with wet hands or when
standing on a wet or damp surface,
or in water.

17. Do not hang this product by the

carry handle. Sewage pumps should
be set firmly on their legs and
supported by rigid piping. This
eliminates twisting and damage
during pump operation.

18.

Do not use an extension cord.

Grounding
Blade

Figure 1B 

www.waynepumps.com

Grounded
Outlet

Figure 1A 

Pump Power Cord

“Switch-
Genius” Plug

Summary of Contents for 330502-001

Page 1: ...njury Warning indicates a potentially hazardous situation which if not avoided COULD result in death or serious injury Caution indicates a potentially hazardous situation which if not avoided MAY result in minor or moderate injury Notice indicates important information that if not followed may cause damage to equipment SAVE THESE INSTRUCTIONS 2007 Wayne Water Systems Specifications CSECAP40 CSE50T...

Page 2: ...mospheres Use pump only with liquids compatible with pump component materials Failure to follow this warning can result in personal injury and or property damage 2 Make certain that the power source electric motor conforms to the requirements of the equipment Disconnect power before servicing If the power dis connect is out of sight lock in the open position and tag it to prevent unexpected applic...

Page 3: ... the pump and or check valve for servicing 5 A union should be installed between the check valve and the pump so the pump can be removed with least disturbance of the piping 6 CSE50T models are supplied with a detachable tether switch with a piggyback plug see figure 3A The length of the tether distance of cord from float to clamp should not be set shorter than 3 1 4 inches and should not be used ...

Page 4: ...s on pump Installation Continued 8 CSECAP40 and CSECAP50 models are supplied with an Switch Genius capacative water sensor see figure 3B Position the pump in the basin so that the Switch Genius water sensor is 180 away from the basin inlet Make certain the incoming water stream does not hit the Switch Genius water sensor surface Before removing pump from basin for service always disconnect electri...

Page 5: ...er 3 If voltage is under recommended minimum check wiring size from the main switch on property If OK contact power company 4 Return for service or replace motor 5 Replace float switch 6 If impeller will not turn remove housing and remove debris 7 Arrange switch so the switch moves freely Reposition pump if necessary 8 Make sure liquid level is at least 13 from the basin floor 1 Install check valv...

Page 6: ...nless water is within 1 inch of the top of the sensor 2 If blown replace with proper sized fuse or reset breaker 3 If voltage is under recommended minimum check wiring size from the main switch on property If OK contact power company 4 Return for service or replace motor 5 Replace Switch Genius 6 If impeller will not turn remove housing and remove debris 7 Make sure liquid level is at least 11 fro...

Page 7: ... 30000 009 1 2 Power cord 31035 001 1 3 Impeller 17317 001 1 4 Volute 41027 001 1 5 Motor Assembly with Shaft Seal 8322 1 Ref No Description Part No Qty www waynepumps com 7 CSECAP40 CSECAP50 CSE50T 1 Capacitive Water Sensor 7465 1 2 Power cord 10 ft 31035 001 1 3 Impeller 17317 001 1 4 Volute 41027 001 1 5 Motor Assembly with Shaft Seal 8322 1 6 Bracket 7434 1 7 Through Bolt 16836 004 1 8 Screw 6...

Page 8: ...PENSES WHATSOEVER IS EXCLUDED Some states do not allow limitations on how long an implied warranty lasts or do not allow the exclusions or limitations of incidental or consequential damages so the above limitations might not apply to you This limited war ranty gives you specific legal rights and you may also have other legal rights which vary from state to state In no event whether as a result of ...

Page 9: ... détectée la pompe démarre automatiquement Cette pompe est conçue pour les stations d élevage d eaux usées domestiques et est convenable pour le pompage des eaux usées eaux d égout eaux résiduaires eaux souterraines et autres liquides non explosifs et non corrosifs avec matières solides jusqu à 5 08 cm 2 pouces Déballage Inspecter cet appareil avant de l utiliser À l occasion les produits sont end...

Page 10: ...is sous tension accidentellemen Ne pas suivre ces directives peut résulter en choc électrique 3 Dissiper toute la pression dans le système avant de procéder à l entretien et aux réparations de n importe quelle pièce détachée Cette pompe contient de l huile à moteur diélectrique pour le transfert de chaleur du moteur Attention en éliminant cette huile Ne pas utiliser cette pompe dans les étangs ou ...

Page 11: ...ice plein qui passera des solides de 2 po ou selon les exigences des codes locaux et de la Province Cette vanne permet l enlevage de la pompe et ou du clapet pour l entretien 5 Installer un raccord union entre le clapet et la pompe pour que la pompe puisse être enlevée sans trop déranger la tuyauterie 6 Les modèles CSE50T sont fournis avec un interrupteur à longe amovible avec fiche d arrimage voi...

Page 12: ...n pour que le capteur d eau Switch Genius soit à 180 de l entrée du bassin Assurez vous que le jet d eau entrant ne frappe pas la surface du capteur d eau Switch Genius Avant d enlever la pompe du bassin pour l entretien toujours couper le courant à la pompe et à l interrupteur de commande Pour procéder à l entretien de la pompe ou l interrupteur TOUJOURS débrancher le cordon d alimentation Ne pas...

Page 13: ...gnie de service publique 4 Retourner pour l entretien ou remplacer le moteur 5 Remplacer l interrupteur flotteur 6 Si la turbine ne tourne pas enlever le carter et enlever le débris 7 Positionner l interrupteur pour qu elle se déplace librement Déménager la pompe si nécessaire 8 S assurer que le niveau de liquide soit au moins 33 02 cm 13 po du fond du bassin 1 Installer un clapet 2 Remplacer l in...

Page 14: ...aille du câblage à partir de l interrupteur principal de la propriété Si OK contactez les services publics d électricité 4 Retournez pour faire réparer ou remplacer le moteur 5 Remplacez le Switch Genius 6 Si l impulseur ne fonctionne pas retirez le boîtier et retirez les débris 7 Assurez vous que le niveau de liquide est à au moins 28 cm 11 po du plancher du bassin 1 Installez la soupape à clapet...

Page 15: ... 31035 001 1 3 Rotor 17317 001 1 4 Volute 41027 001 1 5 Assemblage du moteur avec garniture d étanchéité de l arbre 8322 1 No de No de Réf Description Pièce Qté 15 Fr CSECAP40 CSECAP50 CSE50T 1 Le capteur d eau capacitif 7465 1 2 Cordon d alimentation 10 pi 31035 001 1 3 Rotor 17317 001 1 4 Volute 41027 001 1 5 Assemblage du moteur avec garniture d étanchéité de l arbre 8322 1 6 Support 7434 1 7 B...

Page 16: ...ENSES QUOI QUE SE SOIT EST EXCLUS Certaines Provinces n autorisent pas de limitations de durée pour les garanties implicites ni l exclusion ni la limitation des dommages fortuits ou indirects Les limitations précédentes peuvent donc ne pas s appliquer Cette garantie limitée donne à l acheteur des droits légales précis et vous pouvez avoir autres droits légales qui sont variable d une Province ou d...

Page 17: ...que hay una situación que PODRIA ocasionarle heridas no muy graves Ésto le indica una información importante que de no seguirla le podría ocasionar daños al equipo GUARDE ESTAS INSTRUCCIONES 2007 Wayne Water Systems Materiales de fabricación Material del motor Acero laminado en frío Cubierta del motor Hierro colado Caja espiral Hierro colado Impulsor Plástico PBT reforzado con vidrio Sello de la p...

Page 18: ... toda la presión del sistema antes de darle servicio a cualquier componente 4 Drene todos los líquidos del sistema antes de darle servicio Esta bomba contiene aceite de motor dieléctrico para la transferencia del calor del motor Se debe tener cuidado cuando se deseche este aceite No use esta bomba en estanques o fuentes ya que el aceite de motor puede ser nocivo para la vida acuática 5 Asegure la ...

Page 19: ...ecido por los códigos y ordenanzas locales Esta válvula le permite desconectar la bomba o la válvula de chequeo cuando vaya a darles servicio 5 Debe conectar un empalme entre la válvula de chequeo y la bomba de modo que pueda desconectar la bomba fácilmente 6 Los modelos CSE50T vienen de fábrica con un interruptor de correa desprendible con un enchufe en serie ver figura 3A El largo de la correa l...

Page 20: ...ón Continuación 8 Los modelos CSECAP40 y CSECAP50 vienen de fábrica con un sensor de agua capacitivo Switch Genius Ver figura 3B Disponga la bomba en la pileta de manera que el sensor de agua Switch Genius quede a 180 de la entrada de la pileta Asegúrese de que la corriente de agua en entrada no golpee la superficie del Switch Genius Antes de sacar la bomba de la pileta para darle servicio siempre...

Page 21: ...d Si es adecuado comuníquese con la compañía de electricidad 4 Envie el motor al centro de servicio autorizado más cercano a su domicilio o reemplácelo 5 Reemplace el interruptor flotante 6 Si la propela no gira destápela y límpiela 7 Coloque el interruptor de modo que se mueva sin problemas Reubique la bomba si es necesario 8 Cerciórese de que el nivel de líquido esté por lo menos a 33 cm 13 del ...

Page 22: ... el disyuntor 3 Si el voltaje se encuentra por debajo del mínimo verifique el tamaño del cable del suministro eléctrico general Si está bien llame a la compañía eléctrica 4 Devuelva para realizarle servicio o reemplace el motor 5 Reemplace el Switch Genius 6 Si el impulsor no funciona retire la caja y quite los desechos 7 Asegúrese de que el nivel de líquido sea de al menos 11 28 cm desde el piso ...

Page 23: ...rrea 30000 009 1 2 Cordón de corriente 31035 001 1 3 Impulsor 17317 001 1 4 Caja espiral 41027 001 1 5 Ensamble del motor con sello del eje 8322 1 No de No del Ref Descripción Repuesto Ctd 23 Sp CSECAP40 CSECAP50 CSE50T 1 Sensor de agua capacitivo 7465 1 2 Cordón de corriente de 3m 10pies 31035 001 1 3 Impulsor 17317 001 1 4 Caja espiral 41027 001 1 5 Ensamble del motor con sello del eje 8322 1 6 ...

Page 24: ... LAS REPONSABILIDADES CIVILES DIRECTAS O INDIRECTAS O GASTOS POR DAÑOS INDIRECTOS O CONSECUENTES QUEDAN EXCLUIDOS Algunos estados no permiten que se establezcan límites en la duración de las garantías implicitas o no permiten que se excluyan ni se establezcan límites en los daños por incidentes o consecuencias por lo tanto los límites antes mencionados podrían ser no válidos Esta Garantía Limitada...

Reviews: