Description

A sewage system consists of a pump,
control switch, and a basin for use in
applications where less than six toilets
(units) are discharged into the basin.
The system is generally controlled by a
float switch with a plug-in-plug which
accepts the pump plug and in turn
plugs into a 120 volt outlet. 

The float switch is a wide angle
differential switch that rises with the
liquid level and turns the pump on. As
the liquid level decreases the float
lowers and turns the pump off. The
CSECAP40 and CSECAP50 are provided
with a solid-state electronic “Switch-
Genius” water level control. When

Operating Instructions and Parts Manual

CSECAP40, CSECAP50, CSE50T

330502-001 11/07

water is detected, the pump will start
automatically. This pump is intended
for use in domestic sewage lift stations.
It is suitable for pumping sewage,
effluent, wastewater, groundwater and
other nonexplosive, noncorrosive
liquids with up to 2 inch solids.

Unpacking

Inspect this unit before it is used.
Occasionally, products are damaged
during shipment. If the pump or
components are damaged, return the
unit to the place of purchase for
replacement. Failure to do so could
result in serious injury or death.

Safety Guidelines

This manual contains information that
is very important to know and
understand. This information is
provided for SAFETY and to PREVENT
EQUIPMENT PROBLEMS. 
To help recognize this information,
observe the following symbols.

Danger
indicates

an imminently hazardous situation
which, if not avoided, will result in
death or serious injury.

Warning 
indicates

a potentially hazardous situation
which, if not avoided, COULD result in
death or serious injury.

Caution

indicates

a potentially hazardous situation
which, if not avoided, MAY result in
minor or moderate injury.

Notice 

indicates   

important information, that if not
followed, may cause damage to
equipment.

SAVE THESE INSTRUCTIONS!

© 2007 Wayne Water Systems

Specifications

CSECAP40

CSE50T

CSECAP50

Power supply requirements

120V, 60 hz

120V, 60 hz

Circuit requirements

15 amps (min)

15 amps (min)

Motor duty

Intermittent

Intermittent

Motor

120V, 1 Phase

120V, 1 Phase

Horsepower 1/2

4/10 (CSECAP40)
1/2 (CSECAP50)

Motor full load

12.0

8.7

Liquid temperature range

40°F to 120°F

40°F to 120°F

Max. operating position

45

o

from vertical

45

o

from vertical

Dimensions

14 inches x 12inches 14 inches x 12inches

Intake

2 inches

2 inches

Discharge

2 inch NPT female

2 inch NPT female

Cut-in level (factory set)

19 inches

11 inches

Cut-out level (factory set)

9 inches

3 inches

Differential

10 inches

7 inches

Switch

90

o

wide angle

“Switch-Genius”

mechanical

capacitive 

tether switch

water sensor

Power cord

16 gauge

16 gauge

3 Conductor w/plug

3 Conductor w/plug

Construction

Motor body material .......................Cold rolled steel

Motor housing .................................Cast iron

Volute ...............................................Cast iron

Impeller.............................................Glass reinforced PBT

Seal plate ..........................................Cast Iron

Shaft seal ..........................................Mechanical

GALLONS PER MINUTE AT TOTAL HEAD IN FEET

Model

5'

10'

15'

CSECAP40

90

62

23

CSECAP50, CSE50T

113

90

33

Performance

Sewage
Pump

For parts, product & service information

visit 

www.waynepumps.com

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or 
property damage! Retain instructions for future reference.

Summary of Contents for 330502-001

Page 1: ...njury Warning indicates a potentially hazardous situation which if not avoided COULD result in death or serious injury Caution indicates a potentially hazardous situation which if not avoided MAY result in minor or moderate injury Notice indicates important information that if not followed may cause damage to equipment SAVE THESE INSTRUCTIONS 2007 Wayne Water Systems Specifications CSECAP40 CSE50T...

Page 2: ...mospheres Use pump only with liquids compatible with pump component materials Failure to follow this warning can result in personal injury and or property damage 2 Make certain that the power source electric motor conforms to the requirements of the equipment Disconnect power before servicing If the power dis connect is out of sight lock in the open position and tag it to prevent unexpected applic...

Page 3: ... the pump and or check valve for servicing 5 A union should be installed between the check valve and the pump so the pump can be removed with least disturbance of the piping 6 CSE50T models are supplied with a detachable tether switch with a piggyback plug see figure 3A The length of the tether distance of cord from float to clamp should not be set shorter than 3 1 4 inches and should not be used ...

Page 4: ...s on pump Installation Continued 8 CSECAP40 and CSECAP50 models are supplied with an Switch Genius capacative water sensor see figure 3B Position the pump in the basin so that the Switch Genius water sensor is 180 away from the basin inlet Make certain the incoming water stream does not hit the Switch Genius water sensor surface Before removing pump from basin for service always disconnect electri...

Page 5: ...er 3 If voltage is under recommended minimum check wiring size from the main switch on property If OK contact power company 4 Return for service or replace motor 5 Replace float switch 6 If impeller will not turn remove housing and remove debris 7 Arrange switch so the switch moves freely Reposition pump if necessary 8 Make sure liquid level is at least 13 from the basin floor 1 Install check valv...

Page 6: ...nless water is within 1 inch of the top of the sensor 2 If blown replace with proper sized fuse or reset breaker 3 If voltage is under recommended minimum check wiring size from the main switch on property If OK contact power company 4 Return for service or replace motor 5 Replace Switch Genius 6 If impeller will not turn remove housing and remove debris 7 Make sure liquid level is at least 11 fro...

Page 7: ... 30000 009 1 2 Power cord 31035 001 1 3 Impeller 17317 001 1 4 Volute 41027 001 1 5 Motor Assembly with Shaft Seal 8322 1 Ref No Description Part No Qty www waynepumps com 7 CSECAP40 CSECAP50 CSE50T 1 Capacitive Water Sensor 7465 1 2 Power cord 10 ft 31035 001 1 3 Impeller 17317 001 1 4 Volute 41027 001 1 5 Motor Assembly with Shaft Seal 8322 1 6 Bracket 7434 1 7 Through Bolt 16836 004 1 8 Screw 6...

Page 8: ...PENSES WHATSOEVER IS EXCLUDED Some states do not allow limitations on how long an implied warranty lasts or do not allow the exclusions or limitations of incidental or consequential damages so the above limitations might not apply to you This limited war ranty gives you specific legal rights and you may also have other legal rights which vary from state to state In no event whether as a result of ...

Page 9: ... détectée la pompe démarre automatiquement Cette pompe est conçue pour les stations d élevage d eaux usées domestiques et est convenable pour le pompage des eaux usées eaux d égout eaux résiduaires eaux souterraines et autres liquides non explosifs et non corrosifs avec matières solides jusqu à 5 08 cm 2 pouces Déballage Inspecter cet appareil avant de l utiliser À l occasion les produits sont end...

Page 10: ...is sous tension accidentellemen Ne pas suivre ces directives peut résulter en choc électrique 3 Dissiper toute la pression dans le système avant de procéder à l entretien et aux réparations de n importe quelle pièce détachée Cette pompe contient de l huile à moteur diélectrique pour le transfert de chaleur du moteur Attention en éliminant cette huile Ne pas utiliser cette pompe dans les étangs ou ...

Page 11: ...ice plein qui passera des solides de 2 po ou selon les exigences des codes locaux et de la Province Cette vanne permet l enlevage de la pompe et ou du clapet pour l entretien 5 Installer un raccord union entre le clapet et la pompe pour que la pompe puisse être enlevée sans trop déranger la tuyauterie 6 Les modèles CSE50T sont fournis avec un interrupteur à longe amovible avec fiche d arrimage voi...

Page 12: ...n pour que le capteur d eau Switch Genius soit à 180 de l entrée du bassin Assurez vous que le jet d eau entrant ne frappe pas la surface du capteur d eau Switch Genius Avant d enlever la pompe du bassin pour l entretien toujours couper le courant à la pompe et à l interrupteur de commande Pour procéder à l entretien de la pompe ou l interrupteur TOUJOURS débrancher le cordon d alimentation Ne pas...

Page 13: ...gnie de service publique 4 Retourner pour l entretien ou remplacer le moteur 5 Remplacer l interrupteur flotteur 6 Si la turbine ne tourne pas enlever le carter et enlever le débris 7 Positionner l interrupteur pour qu elle se déplace librement Déménager la pompe si nécessaire 8 S assurer que le niveau de liquide soit au moins 33 02 cm 13 po du fond du bassin 1 Installer un clapet 2 Remplacer l in...

Page 14: ...aille du câblage à partir de l interrupteur principal de la propriété Si OK contactez les services publics d électricité 4 Retournez pour faire réparer ou remplacer le moteur 5 Remplacez le Switch Genius 6 Si l impulseur ne fonctionne pas retirez le boîtier et retirez les débris 7 Assurez vous que le niveau de liquide est à au moins 28 cm 11 po du plancher du bassin 1 Installez la soupape à clapet...

Page 15: ... 31035 001 1 3 Rotor 17317 001 1 4 Volute 41027 001 1 5 Assemblage du moteur avec garniture d étanchéité de l arbre 8322 1 No de No de Réf Description Pièce Qté 15 Fr CSECAP40 CSECAP50 CSE50T 1 Le capteur d eau capacitif 7465 1 2 Cordon d alimentation 10 pi 31035 001 1 3 Rotor 17317 001 1 4 Volute 41027 001 1 5 Assemblage du moteur avec garniture d étanchéité de l arbre 8322 1 6 Support 7434 1 7 B...

Page 16: ...ENSES QUOI QUE SE SOIT EST EXCLUS Certaines Provinces n autorisent pas de limitations de durée pour les garanties implicites ni l exclusion ni la limitation des dommages fortuits ou indirects Les limitations précédentes peuvent donc ne pas s appliquer Cette garantie limitée donne à l acheteur des droits légales précis et vous pouvez avoir autres droits légales qui sont variable d une Province ou d...

Page 17: ...que hay una situación que PODRIA ocasionarle heridas no muy graves Ésto le indica una información importante que de no seguirla le podría ocasionar daños al equipo GUARDE ESTAS INSTRUCCIONES 2007 Wayne Water Systems Materiales de fabricación Material del motor Acero laminado en frío Cubierta del motor Hierro colado Caja espiral Hierro colado Impulsor Plástico PBT reforzado con vidrio Sello de la p...

Page 18: ... toda la presión del sistema antes de darle servicio a cualquier componente 4 Drene todos los líquidos del sistema antes de darle servicio Esta bomba contiene aceite de motor dieléctrico para la transferencia del calor del motor Se debe tener cuidado cuando se deseche este aceite No use esta bomba en estanques o fuentes ya que el aceite de motor puede ser nocivo para la vida acuática 5 Asegure la ...

Page 19: ...ecido por los códigos y ordenanzas locales Esta válvula le permite desconectar la bomba o la válvula de chequeo cuando vaya a darles servicio 5 Debe conectar un empalme entre la válvula de chequeo y la bomba de modo que pueda desconectar la bomba fácilmente 6 Los modelos CSE50T vienen de fábrica con un interruptor de correa desprendible con un enchufe en serie ver figura 3A El largo de la correa l...

Page 20: ...ón Continuación 8 Los modelos CSECAP40 y CSECAP50 vienen de fábrica con un sensor de agua capacitivo Switch Genius Ver figura 3B Disponga la bomba en la pileta de manera que el sensor de agua Switch Genius quede a 180 de la entrada de la pileta Asegúrese de que la corriente de agua en entrada no golpee la superficie del Switch Genius Antes de sacar la bomba de la pileta para darle servicio siempre...

Page 21: ...d Si es adecuado comuníquese con la compañía de electricidad 4 Envie el motor al centro de servicio autorizado más cercano a su domicilio o reemplácelo 5 Reemplace el interruptor flotante 6 Si la propela no gira destápela y límpiela 7 Coloque el interruptor de modo que se mueva sin problemas Reubique la bomba si es necesario 8 Cerciórese de que el nivel de líquido esté por lo menos a 33 cm 13 del ...

Page 22: ... el disyuntor 3 Si el voltaje se encuentra por debajo del mínimo verifique el tamaño del cable del suministro eléctrico general Si está bien llame a la compañía eléctrica 4 Devuelva para realizarle servicio o reemplace el motor 5 Reemplace el Switch Genius 6 Si el impulsor no funciona retire la caja y quite los desechos 7 Asegúrese de que el nivel de líquido sea de al menos 11 28 cm desde el piso ...

Page 23: ...rrea 30000 009 1 2 Cordón de corriente 31035 001 1 3 Impulsor 17317 001 1 4 Caja espiral 41027 001 1 5 Ensamble del motor con sello del eje 8322 1 No de No del Ref Descripción Repuesto Ctd 23 Sp CSECAP40 CSECAP50 CSE50T 1 Sensor de agua capacitivo 7465 1 2 Cordón de corriente de 3m 10pies 31035 001 1 3 Impulsor 17317 001 1 4 Caja espiral 41027 001 1 5 Ensamble del motor con sello del eje 8322 1 6 ...

Page 24: ... LAS REPONSABILIDADES CIVILES DIRECTAS O INDIRECTAS O GASTOS POR DAÑOS INDIRECTOS O CONSECUENTES QUEDAN EXCLUIDOS Algunos estados no permiten que se establezcan límites en la duración de las garantías implicitas o no permiten que se excluyan ni se establezcan límites en los daños por incidentes o consecuencias por lo tanto los límites antes mencionados podrían ser no válidos Esta Garantía Limitada...