830873-0001 REV 02/20/2023
©Copyright 2023 Wayne Dalton, a division of Overhead Door Corporation
6
“Z” GUIDE
“S” Distance
Location
“E” GUIDE
“S” Distance
Location
ROLLED
ANGLE
GUIDES
1. INSTALL GUIDE ASSEMBLIES
• Locate the guide assemblies such that the ”S” dimension exists
between the guides, as shown in Figure 4.
• The ”S” dimension is shown on the ”DATA SHEET”.
• Both guides MUST be on a level line and both guides MUST be
plumb.
• The ”S” dimension must be held within 1/8” over the entire height of
guides.
• Guide assemblies are designed to rest on floor.
NOTE:
If outside angle is flared, then unbolt the Outside Angle and
the Middle Angle from the Wall Angle. They will be bolted to the Wall
Angle after the curtain installation is complete in Step 13.
Figure 3
Figure 4
Masonry jambs shown, non-masonry jamb Installation is similar.
Wall
Angle
Middle
Angle
Pre-Door Install
Outside
Angle