Preparing the installation site
Only experienced installation professionals who are familiar with local building and safety codes and are
licensed, wherever applicable, by the appropriate government regulatory authorities, should install
outdoor units and antennas.
Warnings
Do not modify the construction of this product. Modifying the operating frequency or
enhancing the transmit output power through the use of external amplifiers or other
equipment is illegal.
This device is for outdoor or indoor use on the condition that operation of this device
causes no harmful interference to authorized radio stations. This device shall not
influence aircraft security and/or interfere with legal communications. If this device is
found to cause interference, the operator of this equipment shall cease operating this
device immediately.
How to prepare
the site:
•
Ascertain the existence of potential posts or poles to which a base station could
be attached. Consider the axis of the post, its placement, and whether extenders
are required.
•
Follow the appropriate electrical and building codes to ensure safe and durable
wiring.
•
The length of the Ethernet cable connecting the unit to the network device (PC,
switch, router, and so on) should not exceed 100 meters. There is no limitation
on the length of the cable connecting the PoE to the unit, as long as the
combined length of the cables connecting the network device to the PoE and the
PoE to the unit does not exceed 100 meters.
Grounding best
practices, using
a data protection
device
1.
Position the protection device as close to the building entrance as possible.
2.
Attach a 10 AWG grounding cable to the ground point on the data protection
device.
3.
Attach the other end of the grounding cable to the grounding bar of the building.
Lightning Surge Protector Connection Diagram