USER MANUAL FOR WAVETREND TAGS

 

 

2 TECHNICAL 

INFORMATION 

All tags consist of the same functional blocks. This functionality is illustrated in the figure below. 

 

Battery

: Lithium Battery provides life-span of up to 10 

years depending on the battery used and the way the tag 

is used and configured. 

Micro

Controller

Radio

Frequency

Generator

Battery

RF

Anti-Tamper

Movement

 

Micro-Controller

: Handles communications and sensors. 

 

Radio Frequency Generator

: Modulates digital data for 

transmission over free air. 

 

Anti-Tamper

: Magnetic sensor used for tamper detection,  

auto-wake functionality and to configure the tag with 

unique properties. 

 

Movement Sensor

: Detect and report movement (Only 

MS options). 

 

RF

: Modulated Radio signal transports data over free air 

via the antenna. 

 

Document No. 

Product No. 

Wavetrend Technologies 

Date 

Page 

EAA-00000-04-UM 

TAGS 

CONFIDENTIAL 

25/04/2007 

7 of 15 

 
© Wavetrend Technologies Limited 2007 
 

Summary of Contents for L-TG100

Page 1: ...Document No Product No Wavetrend Technologies Date Page Copyright Wavetrend Technologies Limited 2003 This document contains information relating to the patented rights of Wavetrend The confidentiali...

Page 2: ...G800 orientations C L Neuhoff 1 4 12 November 2003 Update with new products D Rabe Table 1 Amendment History APPROVALS Number Name Designation Date Signature 1 A Evangelidis Technical Director 2 C L N...

Page 3: ...Most Significant Bit Byte NC No Connection PC Personal Computer PCB Printed Circuit Board Pwr Power RF Radio Frequency RFID Radio Frequency Identification Rx Receive SOM Start of Message TBA To be Ann...

Page 4: ...EMENT SENSING 11 2 3 TAG MOUNTING METHODS 12 2 3 1 TAG ACCESSORIES 12 2 4 ANTI TAMPER 12 3 TROUBLE SHOOTING 13 4 CERTIFICATION 14 4 1 FCC CERTIFICATION 14 4 2 CE CERTIFICATION 14 4 3 RTCA DO 160C CERT...

Page 5: ...d tags are Active Radio Frequency Identification tags i e self powered Tags can be configured to transmit its unique identification with a predefined time interval and can report events such as tamper...

Page 6: ...le data structure consisting of Transmit Interval that is configurable to 0 4 0 8 1 1 5 2 5 10 15 20 30 and 45 second intervals as well as 1 1 5 2 3 5 and 10 minute intervals Tag model and firmware ve...

Page 7: ...Tamper Movement Micro Controller Handles communications and sensors Radio Frequency Generator Modulates digital data for transmission over free air Anti Tamper Magnetic sensor used for tamper detectio...

Page 8: ...6 00 6 00 6 00 6 00 6 00 4 53 0 9 18 28 37 46 55 64 73 83 92 Movement Effect Reed Closed 0 00 1 00 2 00 3 00 4 00 5 00 6 00 7 00 Movement Life Years 0 4 0 8 1 5 30 0 4 1 28 1 28 1 28 1 28 1 28 1 28 1...

Page 9: ...EGAND USER DATA X X 8 PUK WIEGAND USER DATA AGE X X Repetition rate 1 seconds Class Wavetrend info Tag transmitting Expected life Years Expected life Years with tamper armed 1 PUK 6 2 4 5 2 PUK AGE 5...

Page 10: ...K WIEGAND USER DATA AGE X X Repetition rate 5 seconds Class Wavetrend info Tag transmitting Expected life Years Expected life Years with tamper armed 1 PUK 10 8 2 PUK AGE 10 7 8 3 PUK WIEGAND 10 7 5 4...

Page 11: ...vity L W TG100 MS L W TG501 MS L W TG800 MS Most Sensitive Least Sensitive Once the movement sensor has been activated the Movement Alarm Counter will be incremented and the tag will transmit four con...

Page 12: ...501 VHB Tape cut to size and magnet 10 per pack L TA400 Double sided VHB fixing tape for L W TG100 VHB Tape cut to size 10 per pack L TA500 Anti tamper kit for L W TG100 VHB Tape cut to size and magne...

Page 13: ...llic surface L W TG501 and L W TG100 do not work on metallic surfaces Movement sensor not working Movement sensor not fitted Not a MS option tag Tamper not working Magnet not present See paragraph 2 4...

Page 14: ...dth for wideband equipment Frequency stability under low voltage conditions EN55022 Radiated emissions 30MHz 1GHz EN61000 4 3 Radiated immunity 80MHz 1GHz excl 433 92MHz 20MHz EN61000 4 2 Electrostati...

Page 15: ...has been tested and evaluated not to in terfere with pacemakers according to the recommendations of the International Commission on Non Ionising Radiation Protection ICNIRP Document No Product No Wave...