Table C1. OE-2 Option 3
Protocol
Filter Wavelength
Power
Units
Average Power
Limit
Modulation
Measure
Modulation
Units
Modulation
Limit
Rise/Fall times
Limits (in ps)
“User Defined”
Defaults
“Filter 1”
850 nm
dBm
(1)
OMA
uW
(1)
(1)
Gigabit Ethernet
1000BASE-SX GE
850
nm
dBm
-9.5
ER
dB
9
260 rise
210 fall
Gigabit Ethernet
1000BASE-LX
Single Mode
GE
1300 nm
dBm
-11.0
ER
dB
9
260
Gigabit Ethernet
1000BASE-LX
Multimode
GE 1300
nm dBm -11.5 ER dB 9
260
Fibre Channel
100-SM-LC-L
FC
1300 nm
dBm
-9.5
OMA
mW
(4)
320
Fibre Channel
200-SM-LC-L
FC2X
1300 nm
dBm
-11.7
OMA
mW
(4)
160
Fibre Channel
100-M5-SN-I FC
850
nm
dBm
-10
OMA
mW
0.156
300
Fibre Channel
100-M6-SN-I
FC 850
nm dBm -10 OMA mW 0.156 300
Fibre Channel
200-M5-SN-I FC2X 850
nm
dBm
-10
OMA
mW
0.196
150
Fibre Channel
200-M6-SN-I
FC2X 850
nm
dBm
-10
OMA
mW 0.196
150
(1) Leave blank for user setting
(2) Not specified or multiple specs in the standard—leave blank
(3) Future product—reserved. Do not show in
OE-2
software, available with
SIA-3000
(4) The Fibre Channel standard offers a tradeoff between spectral center wavelength, RMS spectral width, and
minimum OMA. Leave OMA limit blank for user to input a limit.
APPENDIX C | Preprogrammed Measurement Limits |