WM_PRJ_Q2400_PTS_005 -007
18th January 2006
Confidential©
All rights reserved
Page:
37
/
51
This document is the sole and exclusive property of WAVECOM. Not to be
distributed or divulged without prior written agreement.
2.10.2.3 Battery cell with regulator
Regulator
2.5 V
±
10%
(With very Low Iq)
+VBATT
2 K
1K
En
Vout
Gnd
Vin
Shottky
Diode
VCC_RTC
Figure 24: RTC supplied by a battery cell with regulator
Estimated range with 2 mAh rechargeable battery: ~3 days.
Warning:
Before battery cell assembly insure that cell voltage is lower than 2.75V to
avoid any damage to the WISMO module.
2.10.2.4 Non Rechargeable battery
This is the less recommended solution.
VCC_RTC
(2.75 V max)
Diode (Ex: BAS16)
10
Ex: CR2016
(VARTA)
Figure 25: RTC supplied by a non rechargeable battery
Estimated range with 85 mAh battery: 4000 h minimum.
Note: The “non rechargeable battery” is always active, except when the module
is ON.