Competent Person 

To ensure that all electrical equipment or devices are inspected, tested and tagged correctly, regulations require 
that a 

‘competent person’ such as a Licensed Electrician be employed to perform the required tests. 

Please refer to the above definition as described in the current 

AS/NZ-3760:2010

 

Standard

 and in addition, to 

any other local legislation or jurisdictions as may be relevant in your State. 

EXAMPLE: 

A person competent to undertake Inspection and Testing of electrical equipment must have:  

 

Knowledge and practical experience of electricity and its hazards.

 

 

A clear understanding of precautions to avoid danger.

 

 

The ability to recognise at all times whether or not it is safe for work to continue. 

 

 

The ability to carry out visual examinations of electrical equipment. 

 

 

The  ability  to  distinguish  between  electrical  equipment  that  is  double  insulated  and  equipment  that  is 
earthed as well as being able to identify the appropriate test for each type. 

 

 

The competency to safely carry out the Earthing Continuity, Insulation Resistance or Leakage Test and 
RCD tests on electrical equipment. 

 

 

The  knowledge  of  how  to  use  the  relevant  testing  instruments,  interpret  and  record  the  results  for 
compliance with the Standard/Workplace requirements. 

 

 

The knowledge to be able to correctly recommend the frequency of testing required. 

 

Due  to  the  potential  hazards  of  electrical  testing,  due  care  must  be 

taken  at  all 

times.

 

Disclaimer 

Limited Warranty   

The Manufacturer warrants its products against defects in materials and workmanship for a period of 12 months 
from the date of purchase.  During the warranty period, the manufacturer will repair (or at its option replace at no 
charge) the product that proves to be defective.  This warranty does not apply if the product has been damaged 
by  accident,  abuse,  misuse  or  mis-application  or  as  a  result  of  service  or  modification  by  anyone  other  than 
manufacturer of the TnT.

 

The  TnT  product  range  of  devices  or  its  manufacturer  IS  NOT  RESPONSIBLE  FOR  INCIDENTAL  OR 
CONSEQUENTIAL  DAMAGES  RESULTING  FROM  THE  BREACH  OF  ANY  EXPRESS  OR  IMPLIED 
WARRANTY,  INCLUDING  DAMAGE  TO  PROPERTY  AND  TO  THE  EXTENT  PERMITTED  BY  LAW,  and 
DAMAGES FOR PERSONAL INJURY. The Distributors of this product cannot assume liability or responsibility for 
any loss or damage resulting from the use of this device.

 

The TnT manufacturer reserves the right to discontinue models, change 

specification, price 

or design, at any time without notice or obligation.

 

 

 
 
 
 
 

 

Summary of Contents for TnT ELB G4-Series

Page 1: ...ad Findon SA 5023 Phone 61 08 8243 3500 Fax 61 08 8243 3501 Email sales wavecom com au Web www wavecom com au Melbourne Office 772A Station Street Box Hill Victoria 3128 Phone 1300 793 301 Fax 61 03 9...

Page 2: ...Wavecom Instruments Portable Appliance Testers Instruction Manual 2...

Page 3: ...ure personal safety The Manufacturer also advises that appliance testing should be conducted by a Competent and suitably trained person as referred to under the current Standard AS3760 2010 as well as...

Page 4: ...tery power bank DO NOT send this item by any shipping company This includes the power bank by itself or with equipment Please remove the battery power bank first If you have any transportation queries...

Page 5: ...ipment The knowledge of how to use the relevant testing instruments interpret and record the results for compliance with the Standard Workplace requirements The knowledge to be able to correctly recom...

Page 6: ...method of construction employs two safety barriers comprising two layers of insulation between dangerous voltages and the user of the equipment The first layer of insulation is formed around the live...

Page 7: ...ps MAXIMUM Resistive Load only Standard TNT Series units A Leakage Test applies power to the Device under Test DUT and measures the imbalance of leakage current from the DUT between the active and neu...

Page 8: ...est function ensures that the appliance is plugged into the TnT appliance tester and that it is switched on If the device is not plugged in and the TnT appliance tester detects that no device is prese...

Page 9: ...components if fitted are checked All labels markings and warning indicators of the maximum load to be connected to the device are legible and intact The insulation is not damaged in any way i e melted...

Page 10: ...rvice Refer to the Technical Information section to change test voltage Procedure 1 Complete a Visual Inspection Only proceed if test passed 2 Plug device into appliance socket 3 Connect earth clip to...

Page 11: ...Test Ext Lead Test F3 Please Note A Visual Inspection test must be carried out before any others refer to First Test Section The Lead TEST completes the following sequence as part of its comprehensive...

Page 12: ...est to be carried out instead The TNT Series appliance testers have been designed to perform these tests The Leakage Test applies power to the Device Under Test and measures any imbalance or leakage c...

Page 13: ...ncrements The value can be changed by selecting the leakage test time in the options menu See the special functions section of the manual for more details The factory default setting is 20sec The valu...

Page 14: ...t any time The unit will power down after 20 seconds as factory default Caution This test turns the Equipment ON The power leakage test can handle up to 10 Amp Resistive Load MAX Exceeding this value...

Page 15: ...screen displays 1 option at a time You can select this option by pressing the return button To select the next item press the F2 button Pressing the F3 button escapes out of the TnT options menu Chang...

Page 16: ...Ensures appliance is plugged in and turned on Earth Bond Test 200mA test current Pass level Less than 1 0 Measurement 0 01 to 10 Insulation Test 500VDC 250VDC Pass level Greater than 1M Measurement 0...

Page 17: ...h green and device will power up Otherwise press enter to exit Warning Screen Amps Screen Watts Screen Volts Amps Screen Press the enter key to stop the power mode and return to volts Pressing F3 key...

Page 18: ...uting systems may draw from a power grid the VA is used to determine the kind of wiring and circuit breakers required to support the computing equipment in question Watts and VA Detailed Explanation T...

Page 19: ...he USB B port in the rear of the unit with USB A port on power bank using the supplied cable Press the Enter button for 2 seconds until the unit starts up To shut down the unit keep pressing the same...

Page 20: ...cations worldwide are constantly changing and that Local State and National Regulatory Authorities may also have differing or additional requirements It is strongly recommended the Purchaser check Loc...

Page 21: ...rder information TA TAGS Part no WCM TA TAG BL GN Y O BLK Colour BL Blue GN Green Y Yellow O Orange BLK Black ATT TAGS Roll of 250 These laminated generic tags come in various colours and in rolls of...

Page 22: ...th all regulations noting that extensive penalties can be imposed by the relevant authorities for any breach The IATA and other laws and regulations covering the transport of goods are very comprehens...

Page 23: ...Wavecom Instruments Portable Appliance Testers Instruction Manual 23...

Page 24: ...liance Testers Instruction Manual 24 Portable Appliance Testers TnT G4 Series www wavecom com au V010613 Note TnT Firmware TnT G4 series in general have the ability to be updated to comply with potent...

Reviews: