Step 5. Turn off the cold water supply to the faucet by turning the angle stop valve completely off.
Open cold water sink faucet to relieve pressure.
Step 6. Choosing the configuration that fits your plumbing, attach the adapt-a-valve as illustrated in
the four photos above.
Adapt-a-Valve Installation
Do not use Teflon tape with the Adapt-a-Valve.
WARNING:
Caution: Water supply line to the system must be from the cold water supply line only.
Hot water will severely damage your system.
3/8” Configuration
(With Brass Fittings)
* Insert White Washer
1/2” Configuration
(Without Brass
Fittings)
*White
Washer
Hot
Supply
Cold
Supply
Hot
Supply
Cold
Supply
Verify contents prior to installation:
( 1 ) - Plastic Adapt-a-Valve with black collet
( 1 ) - Brass Adapter no washer
( 1 ) - Brass Adapter with black washer
( 1 ) - White rubber washer
Make sure that the black collet is installed in to the 1/4” opening on the Adapt-a-valve.
Don’t forget to install the white compression washer with the 3/8” configuration.
Brass adapter (A) does not need to be tightened with a wrench, only finger tight.
Black
Collet
A
TIPS:
A
White
Washer
Mount the Reverse Osmosis Faucet
Refer to installation instructions found on faucet box.
If installing an Air-Gap faucet, connect tubes to the faucet prior to mounting:
1/4” Red Tube - Air Gap Feed - Off Center Fitting
3/8” Black Tube - Air Gap Drain - Off Center Fitting
3/8” Blue Tube - Drinking Water - Center Connection
If installing a Non Air-Gap faucet connect:
3/8” Blue Tube - Drinking Water - Center Connection