Page 10
Connect Yellow Tube from TANK Port on RO Module to the Tank
Position tank in desired location. Stand it upright or lay it on its
side (using the black plastic stand). Measure the yellow tube from
the RO module port marked TANK over to the tank and cut it to
desired length.
Insert the white 1/4” tube through tank valve compression nut.
Place 1/4” plastic insert in tubing. Push tubing into valve. Hand
tighten the compression nut securely, and add 1/4 turn with a
wrench.
Step 22
Step 19
Step 21
Step 20
Adapta Valve
Remove a brass nut, plastic sleeve and brass insert from the parts
bag. Place nut on the tube fi rst, then the sleeve (Small taper end
of sleeve must point to the end of tube) and then insert the brass
insert into the end of the tube.
Insert the black tube into the ¼” opening on the adapta valve until
it stops. Slide nut and sleeve down and thread onto the male pipe
threads. Use a ½” wrench to securely tighten. Run the tube to the
inlet on the side label IN of the RO system. Leave enough tube so
it is not kinked and cut the tube to desired length.
Connect BlackTube from Adapta Valve to IN Port on RO module
Note: The DRAIN & TANK
connections are underneath
the bracket. See page 12
DRAIN
FAUCET
TANK
Yellow Tube Connection
Determine if you have an Airgap or Non Airgap faucet and continue
the following steps to install tubing correctly.
Note:
IN