background image

Page 10

 

 

 
 
 
 

 

 

 

 

 
 
 

 
 

 

Connect Yellow Tube from TANK Port on RO Module to the Tank

Position tank in desired location.  Stand it upright or lay it  on its 
side (using the black plastic stand).  Measure the yellow tube from 
the RO module port  marked TANK  over to the tank and cut it to 
desired length.

Insert the white 1/4” tube through tank valve compression nut.  
Place 1/4” plastic insert in tubing.  Push tubing into valve.  Hand 
tighten the compression nut securely, and add 1/4 turn with a 
wrench.

Step 22

 

 

 

 

 

 

 

 

Step 19

Step 21

Step 20

                        Adapta Valve 

Remove a brass nut, plastic  sleeve and brass insert from the parts 
bag.  Place nut on  the tube fi rst, then the sleeve (Small taper end 
of sleeve must point to the end of tube) and then insert the brass 
insert into the end of the tube. 

Insert the black tube into the ¼” opening on the adapta valve until 
it stops.  Slide  nut and sleeve down and thread onto the male pipe 
threads.  Use a ½” wrench to securely tighten.  Run the tube to the 
inlet on the side label IN of the RO system.  Leave enough tube so 
it is not kinked and cut the tube to desired length.

Connect BlackTube from Adapta Valve to IN Port on RO module

Note:  The DRAIN & TANK 
connections are underneath 
the bracket.  See page 12

DRAIN

FAUCET

TANK

Yellow Tube Connection

Determine if you have an Airgap or Non Airgap faucet and continue 
the following steps to install tubing correctly. 

Note:

IN

Summary of Contents for WQT4RO11-50

Page 1: ...ase read carefully before proceeding with installation Your failure to follow the instructions or operating parameters may lead to the product s failure and possible damage to property Please save thi...

Page 2: ...Carbon filter recommended change 6 months The second stage contains a carbon block filter This helps ensure that chlorine and other materials that cause bad taste and odor are greatly reduced Stage 3...

Page 3: ...or the Faucet in a Stainless Steel Sink 5 Faucet Installation 6 Adapta Valve Installation 7 Reverse Osmosis Module Mounting 7 Air Gap Non Air Gap Installation 8 Drain Saddle Installation 9 Tank Valve...

Page 4: ...copper tubing is down stream of the RO Be sure to follow any state or local regulations Operational Parameters Note The operating pressure in your home should be tested over a 24 hour period to attai...

Page 5: ...l or liquid soap to keep the hole saw cool during cutting Step 2 Drill a Hole for the Faucet in a Porcelain Sink Punch a Hole for the Faucet in a Stainless Steel Sink Drill a pilot hole Use a 1 2 Hole...

Page 6: ...llips head screwdriver turn the screw clockwise until the toggle bolt secures the faucet base snug onto the sink top do not over torque toggle bolt 5lb in max Once the faucet base is securely fastened...

Page 7: ...en doing maintenance on unit Step 10 Step 12 Attach adapta valve as illustrated in the three photos above choosing the configuration that fits your plumbing When attaching the adapta valve to straight...

Page 8: ...Page 8 Non Air Gap Faucet Installation Air Gap Faucet Installation...

Page 9: ...ircle cut out of the middle must be applied to the inside of the drain saddle Remove sticky tape backing and stick to the drain saddle as shown 2 Screws 1 Semi bracket with opening 2 Nuts for screws 1...

Page 10: ...e parts bag Place nut on the tube first then the sleeve Small taper end of sleeve must point to the end of tube and then insert the brass insert into the end of the tube Insert the black tube into the...

Page 11: ...Use the Quick Connect Fittings on the RO Module To make a connection the tube is simply pushed into the fitting It is essential that the outside diameter be free of score marks and that burrs and sha...

Page 12: ...ve carbon particles from final filter Repeat this step two more times The fourth tank can be used for drinking Note The flushing of the tank 3 times is only necessary during initial installation This...

Page 13: ...component should be with one of identical specifications as defined by the manufacturer to assure the same efficiency and contaminant reduction performance Periodic inspection and following proper sy...

Page 14: ...ply at the adapta valve Step 7 Allow the RO unit to fill the tank overnight Step 8 Open the faucet and allow the tank to empty and then close the faucet Step 9 Replace the post carbon filter cartridge...

Page 15: ...on Use If the system will not be used for an extended period more than 2 months perform the following Turn on the water supply at the adapta valve Step 1 Step 2 Step 3 Step 4 Step 5 Turn off the incom...

Page 16: ...e Page 15 4 Noise from faucet or drain Air gap faucet Inherent sound with air gap faucets Location of drain saddle See diagram for proper location of drain saddle Higher capacity membrane Normal with...

Page 17: ...Purchase __________ Date of Install ___________ Installed by __________________ Serial No _____________________ Date 1st stage Sediment 6 months 2nd stage Carbon 6 months 4th stage Carbon 1 year 3rd...

Page 18: ...2 The hardness of the water should not exceed 10 grains per gallon or 170 ppm 3 Maximum incoming iron must be less than 0 2 ppm 4 The pH of the water must not be lower than 2 or higher than 11 5 The i...

Page 19: ...TORAGE TANK WHITE PLASTIC 7 1 PPSV501222W VAVLE BALL 3 8 x 1 4 FEMALE ELBOW 8 1 WTMFAG C FCT TOP MOUNT CHROME AIRGAP FAUCET 9 1 FU WDF 103 3NSF FCT LONG REACH CHROME NON AIR GAP 10 1 FU AGLR C 3 FCT L...

Reviews: