background image

 

4

 
 
 
 

Step 1: Location 

a)  WM-120 to be mounted to a wall with feed 

water supply, drain and storage tank within 
15 ft. of location. Controller box to be 
mounted within 6 ft of WM and electrical 
outlet within 12 ft. Review general 
plumbing layouts as references for 
installation of pre- or post-treatment 
equipment on page 3. 

b)  Mounting location should have clearance of 

2 inches on both sides including; 2 inches 
from the bottom of pre -filter housing for 
filter changes. See figure 1, page 2. 

 

Step 2: Mounting WM to Wall 

a)  The WM-120 mounting bracket has (2) 

mounting keyholes that are 10.75 inches on 
center. 

b)  The WM-120 will have an approximate 

weight of 75 pounds. Caution needs to be 
used when mounting unit to the wall.  Use 
molly bolts or self-anchoring screws with 
¼” diameter heads.  For sheet rock wall at 
least (1) mounting screw should be located 
at a wall stud. 

c)  The WM-bracket is designed so that if using 

mounting screws with a head size of ¼” or 
less in diameter, the head of the screw will 
pass through the keyhole. See drawing 
below) 

Figure 2 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
d)  When screwing screw into wall, allow 1/16” 

clearance between the screw head and the 
wall. The WM-bracket will slide between 
the screw head and the wall. 

 
 

Step 3: Connecting to Feed water supply: 

The WM may come with either a Self-Piecing 
Valve, or Easy Tap Adapter. 
 
WM-120 supplied with a Self-Piercing Valve 
follow Processor A.  
WM-120 supplied with an Easy Tap Adapter 
follow Processor B. 
 

Processor A 

TO INSTALL SELF-PIERCING VALVE ON 

COPPER TUBE 

 
CAUTION: 

Do not turn handle before or while 

installing (Self-Piercing Valve) be sure the 
piercing lance does not protrude beyond the 
rubber gasket. 

Failure to do this may result in 

damage to the piercing needle. 

 
a)  Turn off the water supply at the location of 

installation of the Self-Piercing Valve.  

b)  Assemble the Self-Piercing Valve on copper 

tubing. For 3/8” OD tubing using Patent 
Pending bracket with side projections to 
prevent distortion of tubing.  Use “V” side 
of bracket for all larger tubing. 

c)  Tighten screws firmly and evenly, brackets 

should be parallel. 

d)  Connect ¼” green tubing of the unit to the 

Self-Piercing Valve as shown in figure C.   

e)  Turn the handle clockwise until you feel it is 

firmly seated. Note: you have now pierced 
the copper tube and the valve is closed. 

f) 

Turn on the cold water supply, then turn the 
handle counter-clockwise to open the self-
piercing valve. 

g)  Check for leaks and repair if any. 
 

TO INSTALL SELF-PIERCING VALVE ON 

STEEL OR BRASS PIPE 

 
a)  Shut-off the water supply and drain the line. 
b)  Drill a 3/16” (0.24 cm) hole in pipe. Use a 

hand drill to avoid shock hazard. 

c)  Turn handle to expose lance beyond the 

rubber gasket no more than 3/16” (0.24 cm). 

d)  Place body of valve over the hole so that the 

lance fits into the hole. 

BRACKET

KEYHOLE

SCREW

Summary of Contents for WM-120-PT

Page 1: ...th water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system Revised October 2002 Watts Pure Water Inc 1725 W Williams Dr C 20 Phoenix AZ 85027 623 505 1512 Office 602 588 0356 FAX www wattspurewater com Premier Water Systems ...

Page 2: ... Water in Phoenix Arizona U S A 888 774 7405 Figure 1 Shut off valve Inlet ball valve Flush ball valve Flow Restrictor Note Ball valves shown in closed position WM 120 Polyethylene tubing is color coded for easy installation a OD Green Polyethylene tubing to be connected to a cold water feed supply b OD Black Polyethylene tubing is for flushing of pre filters and requires no connection c 3 8 OD Re...

Page 3: ...th Final polishing filter Pressure Storage Tank Ordered separately 1 4 blue tubing to storage tank WM 120 PT General plumbing layout For use with Steam Equipment To drain To equipment Note Tee on bottom port of tank 1 4 black tubing Flush 1 4 green tubing Incoming feed water supply Final Carbon Calcite filter Ordered separately Pressure Storage Tank Ordered separately 1 4 blue tubing to storage ta...

Page 4: ...lve or Easy Tap Adapter WM 120 supplied with a Self Piercing Valve follow Processor A WM 120 supplied with an Easy Tap Adapter follow Processor B Processor A TO INSTALL SELF PIERCING VALVE ON COPPER TUBE CAUTION Do not turn handle before or while installing Self Piercing Valve be sure the piercing lance does not protrude beyond the rubber gasket Failure to do this may result in damage to the pierc...

Page 5: ...Figure C2 b Teflon tape the 1 8 male pipe thread of the easy tap valve and screw into easy tap valve body c Disconnect the fitting where the easy tap valve is to be installed Note When loosening or tightening fitting use wrenches on both sides of fittings d Insert the easy tap gasket into t he female thread side of easy tap No plumber putty or Teflon tape is required on thread e Thread easy tap va...

Page 6: ...e must be reduced The air pressure setting in a pressurized storage tank should be checked and set between 7 to 10 psi when the tank is empty of water for correct operation of the WM 120 PT The blue plastic tubing is the line the RO water flows through from the WM 120 The blue tubing connects to a pressurized storage tank or post treatment equipment depending on the application NOTE Adding ball va...

Page 7: ...feeding into the storage tank g Turn on water supply to RO unit and allow WM to produce water for 2 hours h If you have ball valve after the storage tank or before the post filter housing you may shut the RO water supply off at that point i Open faucet at the furthest point from storage tank to depressurize Ro water lines Add post filter cartridge back to its filter housings j Close faucet and ope...

Page 8: ... 10 Elbow Plastic C x M 90o 3 Inlet Feed Ball Valve Brass F 11 Automatic Shut Off Valve 4 0 100 Pressure Gauge M Bottom Mount 12 Membranes Pressure Vessel 2 5 Filter Housing 20 Blue 3 13 Check Valve Elbow Plastic C x M 90o 2 6 0 100 Pressure Gauge M Bottom Mount 14 Flow Restrictor 850 ml 7 Flush Ball Valve Brass F 15 Drain Line 3 8 Red Plastic Tubing 15 feet 8 Flush Tubing Black 6 feet 16 Permeate...