8. Directives

Designation

Description

Link

Low Voltage Directive (LVD)

The Low Voltage Directive (LVD) (2014/35/EU) ensures that 
electrical equipment within certain voltage limits provides a high 
level of protection for European citizens, and benefits fully from 
the Single Market.

2014/35/UE

Electromagnetic Compatibility (EMC)
Directive 2014/30/EU

The Electromagnetic Compatibility (EMC) Directive 2014/30/EU 
ensures that electrical and electronic equipment does not 
generate, or is not affected by, electromagnetic disturbance.

2014/30/UE

Restriction of the use of certain 
hazardous substances Directive (RoHS) 
2011/65/EU

Directive on the restriction of the use of certain hazardous 
substances in electrical and electronic equipment.

2011/65/EU

Waste Electrical & Electronic Equipment
Directive (WEEE)

The WEEE Directive (2012/19/EU) aims to reduce the amount of 
waste electrical and electronic equipment that ends up in landfill.

2012/1
9/EU

Ecodesign Commission Regulation

Ecodesign requirements for local space heaters.

2015/1188

Radio Equipment Directive (RED) 
2014/53/EU

The Radio Equipment Directive 2014/53/EU (RED) establishes a 
regulatory framework for placing radio equipment on the market.

2014/53/EU

Summary of Contents for WFC-03 HCM RF 230

Page 1: ...wattswater fr WFC 03 HCM RF 230 Water Floor Heating and Cooling module Installation manual...

Page 2: ...PRODUCT DESCRIPTION 4 LED color meanings 4 Push button 4 DIP switch configuration 4 INPUTS OUTPUTS 5 Power Supply 5 Heating cooling Input 5 Pump Output 6 Humidity detection input 6 Dehumidifier output...

Page 3: ...tion complies with existing regulations before operation to ensure proper use of the installation 2 Presentation The WFC 03 HCM RF 230 is especially designed to control heating and cooling in combinat...

Page 4: ...Error Led Red Blue Green Red blinking NTC error Blue blinking Global humidity detection In that case the dehumidifier is triggered Fix Green Pump is triggered Green Blue blinking Global humidity detec...

Page 5: ...mode is then propagate over all the system Only one device is the system should be able to select the H C mode Master H C device Other possible H C switch signal sources BT CT02 RF Central unit H C in...

Page 6: ...4 4 When the WFC 03 HC RF controller orders the dehumidifier 4 4 Humidity detection input When DIP1 ON See 3 3 the product manages a humidity detection input with 2 possible types of signal depending...

Page 7: ...ll the time 4 7 External antenna The distance between 2 devices with internal antenna should be at least 50cm The controller embeds an internal antenna If require an external antenna can be connected...

Page 8: ...lave device mode All LEDs are blinking green When link is completed WFC 03 HC RF returns to the RF pairing menu and WFC 03 HCM RF 230 returns to normal mode 5 System configuration The WFC 03 HCM RF 23...

Page 9: ...WFC 03 HCM RF 230 improves the RF communication Usage of a repeater paired to the WFC 03 HC RF may be required Red blinking on Pump Humidity Led NTC error If DIP4 ON a water temperature sensor should...

Page 10: ...ctromagnetic disturbance 2014 30 UE Restriction of the use of certain hazardous substances Directive RoHS 2011 65 EU Directive on the restriction of the use of certain hazardous substances in electric...

Page 11: ...ation sheet are supplied by way of information only and are not binding Watts Industries reserves the right to carry out any technical and design improvements to its products without prior notice Warr...

Reviews: