Troubleshooting LXT

Error Codes

NOTE: Error codes appear on the In Service display.

Error Code

Error Type

Cause

Reset and Recovery

0

Motor Stall /Cam 

Sense Error

No state changes in the optical sensor 

are detected for 6 seconds.

Unplug the unit an plug back in. Allow the control to attempt to find position again.

Verify the optical sensor is in place with the wires connected to the circuit board. 

Verify the motor and drive train components are in good condition and assembled 

properly. Check the valve and verify that the piston travels freely. Replace/reassemble 

the various components as necessary.

Plug the unit back in and observe its behavior. If the error reoccurs, unplug the unit, 

put it into bypass and contact technical support.

1

Motor Run-On Error /

Cycle Sense Error

An undesired optical sensor state change 

occurred.

Non-critical error. Extra optical sensor pulse detected. Press any button to clear the 

error. Press extra cycle button to advance motor to clear error.

2

Regen Failure

The system has not regenerated in 30 

days.

Perform a Manual Regeneration to reset the error code. 

If the system is metered, verify that it is measuring flow by running service water and 

watching for the flow indicator on the display. If the unit does not measure flow, verify 

that the meter cable is connected properly and that the meter is functioning properly.

Enter Master Programming Mode and verify that the unit is configured as appropriate 

for the valve configuration. Check that the correct system capacity and meter size 

has been selected.

4

Fail Safe Error

Valve has failed to find position in one 

minute.

Unplug the unit and plug it back in. If error continues, call technical support.

W110 LXT Downflow Softeners and SXT Filters   

 

   28

Summary of Contents for W110 LXT

Page 1: ... Diagrams 26 Troubleshooting LXT 28 Troubleshooting SXT 29 Job Specification Sheet 30 NOTES 31 WARNING Read this Manual BEFORE using this equipment Failure to read and follow all safety and use information can result in death serious personal injury property damage or damage to the equipment Keep this Manual for future reference You are required to consult the local building and plumbing codes pri...

Page 2: ...00 15 15 7 310 NOTE Brine tanks come with safety float valve CHART 2 W110 Series Backwashing Micro Z Filters With SXT Timers MODEL NO VALVE PIPE SIZE IN TANK SIZE MEDIA CU FT PEAK SERVICE FLOW GPM BACKWASH GPM FLOOR SPACE L x W x H SHIP WT LBS NM09 W110 W110 1 9 x 48 1 9 7 16 x 10 x 55 110 NM10 W110 W110 1 10 x 54 1 5 10 7 16 x 11 x 62 140 NM12 W110 W110 1 12 x 52 2 15 12 17 x 13 x 60 200 NM14 W11...

Page 3: ...BACKWASH GPM FLOOR SPACE L x W x H SHIP WT LBS NC09 W110 W110 1 9 x 48 1 4 4 16 x 10 x 55 80 NC10 W110 W110 1 10 x 54 1 5 6 5 16 x 11 x 62 105 NC12 W110 W110 1 12 x 52 2 8 7 17 x 13 x 60 145 NC14 W110 W110 1 14 x 65 3 11 10 18 x 15 x 74 200 NC16 W110 W110 1 16 x 65 4 14 12 20 x 17 x 74 265 CHART 6 W110 Series Backwashing Empty Filters With SXT Timers MODEL NO VALVE PIPE SIZE IN TANK SIZE MEDIA CU ...

Page 4: ...side down or drop Turning the tank upside down or laying the tank on its side can cause media to enter the valve Use only regenerants designed for water conditioning Do not use ice melting salt block salt or rock salt During cold weather it is recommended that the installer warm the valve to room temperature before operating Teflon is a trademark of E I duPont de Nemours How To Use This Manual Thi...

Page 5: ...ions 1 Turn off water heater s 2 Turn off the main water supply to the home and open an inside faucet cold and hot to relieve any pressure within the plumbing system 3 Place the system in the desired installation location Make sure that the location is level and sturdy enough to support the weight of the system once it is in operation 4 Place the bypass valve in the bypass position 5 Connect the c...

Page 6: ...r Size BLFC Size US FT3 Metric Liters 8 0 75 20 000 0 125 9 25 000 0 125 9 1 00 30 000 0 125 10 1 25 35 00 0 125 10 1 50 40 00 0 125 12 45 00 0 125 12 1 75 50 00 0 125 12 2 00 55 0 0 25 13 60 0 0 25 13 2 25 65 0 0 25 14 2 50 70 1 0 25 14 75 1 0 25 14 2 75 80 1 0 25 14 3 00 85 1 0 25 14 3 25 90 2 0 50 14 95 2 0 50 14 3 50 100 2 0 50 16 3 75 105 3 0 50 16 110 3 0 50 16 4 00 115 3 0 50 W110 LXT Downf...

Page 7: ...ton for 5 seconds Position the valve to backwash Ensure the drain line flow remains steady for 10 minutes or until the water runs clear 3 Position the valve to the brine slow rinse position Ensure the unit is drawing water from the brine tank this step may need to be repeated 4 Position the valve to the rapid rinse position Check the drain line flow and run for 5 minutes or until the water runs cl...

Page 8: ...n 3 Press the Extra Cycle button once to advance valve to Regeneration Cycle Step 2 brine draw slow rinse 4 Press the Extra Cycle button once to advance valve to Regeneration Cycle Step 3 rapid rinse 5 Press the Extra Cycle button once to advance valve to Regeneration Cycle Step 4 brine refill 6 Press the Extra Cycle button once more to advance the valve back to in service NOTE If the unit is a fi...

Page 9: ...thod used to trigger a regeneration Day of the Week controls While in service the display alternates between time of day volume remaining or days to regeneration The Flow Indicator flashes when outlet flow is detected The Service Icon flashes if a regeneration cycle has been queued Meter volume and capacity values are not displayed on SXT filter systems A Regeneration can be triggered immediately ...

Page 10: ...he valve in service While in the Program Mode the control continues to operate normally monitoring water usage and keeping all displays up to date Control programming is stored in memory permanently G Manually Initiating a Regeneration 1 When timer is in service press the Extra Cycle button for 5 seconds on the main screen 2 The timer advances to Regeneration Cycle Step 1 backwash and begins progr...

Page 11: ...timer range is 5 100 liters 6 Hold the Extra Cycle button until the Program icon disappears to save your programming 7 If you are just changing one program step hold the Extra Cycle button until the Program icon disappears to save your changes If you do not hold the Extra Cycle button until the Program icon disappears your changes will not be saved This unit has a day of the week reserve It calcul...

Page 12: ...ot hold the Extra Cycle button until the Program icon disappears your changes will not be saved This unit has a day of the week reserve It calculates a reserve for each day of the week based on the past 4 weeks D W110 Filter Time Clock Time of Day Time of Backwash Backwash Length Days Between Regens Days to Backwash Resin PM MODE Figure 10 1 Press the Mode button to advance to Time of Backwash Pus...

Page 13: ...of software D Downflow U Upflow A1 Displays the average water usage for day 1 in cubic meters A2 Displays the average water usage for day 2 in cubic meters A3 Displays the average water usage for day 3 in cubic meters A4 Displays the average water usage for day 4 in cubic meters A5 Displays the average water usage for day 5 in cubic meters A6 Displays the average water usage for day 6 in cubic met...

Page 14: ...s reserve DO Day Override The system s day override setting RT Regen Time The time of day the system will regenerate BW BD RR BF Regen Cycle Step Times The time duration for each regeneration step Adjustable from OFF and 0 199 minutes NOTE If Othr is chosen under Valve Type then C1 C2 C20 will be displayed along with available cycle steps RR BD SR BW RF SP LC denotes the Last Cycle D1 D2 D3 D4 D5 ...

Page 15: ...seconds while in normal Service mode This resets all parameters to the system default values Not reset are the volume remaining in meter immediate or meter delayed systems and days since regeneration in the time clock system Master Reset Hold the Extra Cycle button while powering up the unit This resets all of the parameters in the unit Check and verify the choices selected in Master Programming M...

Page 16: ...n set to one of the metered options Use the Up and Down buttons to adjust the value as needed Figure 17 Range 1 199 grains mg l 7 Reserve Selection Display Code RS Press the Extra Cycle button Use this display to set the Safety Factor and to select the type of reserve to be used in your system This setting is identified by RS in the upper left hand corner of the screen The reserve selection parame...

Page 17: ...r left hand corner of the screen The abbreviations used are listed below Abbreviation Cycle Step BD Brine Draw BF Brine Fill AD Air Draw BW Backwash RR Rapid Rinse SV Service If the system has been configured with the Other valve type the regeneration cycles will be identified as C1 C2 C20 Cycle steps can be programmed in any order using the Up or Down buttons with the following selections Up to 2...

Page 18: ...wn buttons to select one of the 8 available settings Abbreviation Description P0 7 3 4 Paddle Wheel Meter t0 7 3 4 Turbine Meter P1 0 1 Paddle Wheel Meter t1 0 1 Turbine Meter P1 5 1 5 Paddle Wheel Meter t1 5 1 5 Turbine Meter P2 0 2 Paddle Wheel Meter Gen Generic or Other non Fleck Meter Figure 26 16 Meter Pulse Setting Display Code K Press the Extra Cycle button Use this display to specify the m...

Page 19: ...ay to adjust the Day Override This option setting is identified by DO in the upper left hand corner of the screen Figure 28 3 Press the Extra Cycle button Use this display to adjust the Regeneration Time This option setting is identified by RT in the upper left hand corner of the screen Figure 29 4 Press the Extra Cycle button Use this display to adjust the Feed Water Hardness This option setting ...

Page 20: ...setting is identified by FR in the upper left hand corner of the screen Figure 33 3 Press the Up button Use this display to view the Peak Flow Rate since the last regeneration cycle This option setting is identified by PF in the upper left hand corner of the screen Figure 34 4 Press the Up button Use this display to view the Hours in Service since the last regeneration cycle This option setting is...

Page 21: ...1 61832 00 Cover Assembly Black Blue 2 1 61836 Panel Gear Assembly Downflow Upflow 3 1 E Timer 4 1 61835 Motor Assembly Call your distributor for part number MODE jdofue jdofue jdofue jdofue jdofue jdofue 1 2 3 4 21 W110 LXT Downflow Softeners and SXT Filters ...

Page 22: ...Item No QTY Part No Description 1 1 61832 00 Cover Assembly Black Blue 2 1 61836 Panel Gear Assembly Downflow Upflow 3 1 61834 Timer Assembly SXT 4 1 61835 Motor Assembly 1 2 3 4 W110 LXT Downflow Softeners and SXT Filters 22 ...

Page 23: ...06 DLFC Plastic 0 60 gpm 1 2 3 4 Item No QTY Part No Description 60705 08 DLFC Plastic 0 80 gpm 60705 10 DLFC Plastic 1 0 gpm 60705 12 DLFC Plastic 1 2 gpm 60705 13 DLFC Plastic 1 3 gpm 60705 15 DLFC Plastic 1 5 gpm 60705 17 DLFC Plastic 1 7 gpm 60705 20 DLFC Plastic 2 0 gpm 60705 24 DLFC Plastic 2 4 gpm 60705 30 DLFC Plastic 3 0 gpm 60705 35 DLFC Plastic 3 5 gpm 60705 40 DLFC Plastic 4 0 gpm 6070...

Page 24: ...40 Yoke 1 Sweat 13708 45 Yoke 3 4 Sweat 19275 Yoke Angle 90 Deg 3 4 NPT 19275 45 Yoke Angle 90 Deg 3 4 Sweat 19620 01 Yoke Assy 3 4 R Angle 90 Deg w O rings Clips Screws 40636 Yoke 1 1 4 NPT 40636 49 Yoke 1 1 4 Sweat 41027 01 Yoke 3 4 NPT Cast Machined 41026 01 Yoke 1 NPT Cast Machined SS 41026 02 Yoke 1 BSP Cast Machined SS 18706 10 Yoke 1 BSP Plastic 41027 02 Yoke 3 4 BSP Cast Machined 18706 12 ...

Page 25: ... x 0 75 4 1 19805 Nut Hex 10 24 Nylon Black 5 1 19652 01 Poppet Assy SBV w O ring 6 1 19649 Flow Dispenser 7 1 11183 O ring 017 8 1 19647 Elbow Safety Brine Valve 9 2 19625 Nut Assy 3 8 Plastic 10 1 18312 Retainer Drain 11 1 60014 Safety Brine Valve Assy 2310 12 2 10150 Grommet 0 30 Dia 13 1 60068 8 06 Float Assy 2310 w 8 06 Rod 60068 10 5 Float Assy 2310 w 10 5 Rod 60068 11 5 Float Assy 2310 w 11...

Page 26: ...er Conditioner Flow Diagrams A Downflow 1 Service Position 2 Backwash Position 3 Brine Slow Rinse Position 4 Rapid Rinse Position 5 Brine Tank Refill Position W110 LXT Downflow Softeners and SXT Filters 26 ...

Page 27: ...w 1 Service Position 2 Backwash Position 3 Brine Slow Rinse Position Water Conditioner Flow Diagrams continued 4 Rapid Rinse Position 5 Brine Tank Refill Position 27 W110 LXT Downflow Softeners and SXT Filters ...

Page 28: ...Sense Error An undesired optical sensor state change occurred Non critical error Extra optical sensor pulse detected Press any button to clear the error Press extra cycle button to advance motor to clear error 2 Regen Failure The system has not regenerated in 30 days Perform a Manual Regeneration to reset the error code If the system is metered verify that it is measuring flow by running service w...

Page 29: ...t regenerated for more than 99 days or 7 days if the Control Type has been set to Day of Week Perform a Manual Regeneration to reset the error code If the system is metered verify that it is measuring flow by running service water and watching for the flow indicator on the display If the unit does not measure flow verify that the meter cable is connected properly and that the meter is functioning ...

Page 30: ..._________ 2 System Type A System 4 1 Tank 1 Meter Immediate or Delayed Re generation B System 4 Time Clock 3 Timer Program Settings A Backwash _______________________________Minutes B Brine and Slow Rinse ______________________Minutes C Rapid Rinse ______________________________Minutes D Brine Tank Refill __________________________Minutes E Pause Time ______________________________Minutes F Second...

Page 31: ...NOTES 31 W110 LXT Downflow Softeners and SXT Filters ...

Page 32: ...IFICALLY DISCLAIMS ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE AND IN NO EVENT SHALL WATTS BE LIABLE IN CONTRACT TORT STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY FOR INCIDENTAL INDIRECT SPECIAL OR CONSEQUENTIAL DAMAGES INCLUDING WITHOUT LIMITATION LOST PROFITS OR PROPERTY DAMAGE REGARDLESS ...

Reviews: