Master Programming Mode SXT
(continued)
10. Day Override (Display Code DO)
Press the Extra Cycle button . Use this display to set the Day
Override . This setting specifies the maximum number of days
between regeneration cycles . If the system is set to a timer-type
control, the day override setting determines how often the system
will regenerate . A metered system will regenerate regardless of
usage if the days since last regeneration cycle equal the day override
setting . Setting the day override value to "OFF" disables this function .
This option setting is identified by "DO" in the upper left hand corner
of the screen . Use the Up and Down buttons to adjust the value as
needed . Specifically, Filox filters need to be set to a DO of 1 .
Figure 21
Range: Off-99 days
11. Regeneration Time
Press the Extra Cycle button . Use this display to set the
Regeneration Time . This setting specifies the time of day the control
will initiate a delayed, manually queued, or day override regeneration .
This option setting is identified by "RT" in the upper left hand corner
of the screen . Use the Up and Down buttons to adjust the value as
needed . Make sure that filters and softeners are set to regenerate 2
hours apart to avoid both units regenerating simultaneously .
Figure 22
12. Regeneration Cycle Step Times
Press the Extra Cycle button . Use this display to set the
Regeneration Cycle Step Times . The different regeneration cycles are
listed in sequence based on the valve type selected for the system,
and are identified by an abbreviation in the upper left-hand corner of
the screen . The abbreviations used are listed below .
Abbreviation
Cycle Step
BD
Brine Draw
BF
Brine Fill
AD
Air Draw
BW
Backwash
RR
Rapid Rinse
SV
Service
If the system has been configured with the "Other" valve type, the
regeneration cycles will be identified as C1, C2, . . ., C20 . Cycle steps
can be programmed in any order using the Up or Down buttons with
the following selections . Up to 20 individual cycles can be set . Time
for each cycle can be set from 0 to 199 minutes . Setting a cycle step
time to 0 will cause the control to skip that step during regeneration,
but keeps the following steps available . Use the Up and Down
buttons to adjust the value as needed . Press the Extra Cycle button
to accept the current setting and move to the next parameter .
Program the last cycle step as LC which forces the valve back to the
service position .
Abbreviation
Cycle Step
RR
Rapid Rinse
BD
Brine Draw
SR
Slow Rinse
BW
Backwash
RF
Refill
SP
Service Position
LC
Last Cycle
Figure 23
Range: 0-199 minutes
13. Day of Week Settings
Press the Extra Cycle button . Use this display to set the regeneration
schedule for a system configured as Day of Week control . The
different days of the week are identified as D1, D2, D3, D4, D5, D6,
and D7 in the upper left-hand corner of the display . Set the value
to "ON" to schedule a regeneration or "OFF" to skip regeneration
for each day . Use the Up and Down buttons to adjust the setting
as needed . Press the Extra Cycle button to accept the setting and
move to the next day . Note that the control requires at least one day
to be set to "ON" If all 7 days are set to "Off", the unit will return to
Day 1 until one or more days are set to "ON" .
Figure 24
17 W110 LXT Downflow Softeners and SXT Filters