5.1 Change temperature setting
Wake-up the thermostat by pressing any key.
Press
or
,
to change the temperature
set point (digits starts to blink).
By pressing validation key
, temperature set point value is validated.
5.1.1 Boost/Timer mode
In mode boost, set point temperature is applied during a selected time.
After this time, thermostat will return to former mode.
You can first adjust, the desired setting temperature with
or
, press validation key
, to validate, default value 24°C.
In a second time, you can adjust the du- ration in hours “H” if below 24H, then in day “
d
”.
With automatic H&C switching configuration, boost/timer mode can’t be selected.
If configuration system is changed by H&C signal, boost/timer mode will be stopped.
Thermostat will return to the previous selected mode.
Default value: “no” (0 minute)
Value range: 1h to 23 hours (step of 1 hour) and 1 day to 44 days (step 1 day).
5.1.2 Comfort mode
In this mode, comfort temperature set point will be followed all the time.
This mode can’t be selected if thermostat is a “slave” product and H&C signal sends
reduced information.
5.1.3 Reduced / ECO mode
In this mode, reduced temperature set point will be followed all the time.
This set point corresponds to comfort set point reduced by an offset (see paragraph 7.2
“User parameter description”).
Reduced/ECO mode is available if if thermostat is in master configuration;
If H&C signal is in ECO mode and the thermostat is configured in slave, the thermostat is
set automaticaly in ECO configuration
Note: In cooling mode, reduced mode acts like the OFF mode (system is stopped, NC
actuators are closed).