16

SXT Controller Operation 

Meter Immediate Control

A Meter Immediate control measures water usage and regener-

ates the system as soon as the calculated system capacity is 

depleted. The control calculates the system capacity by divid-

ing the unit capacity (typically expressed in grains/unit volume) 

by the feedwater hardness and subtracting the reserve. Meter 

Immediate systems generally do not use a reserve volume. 

However, in twin tank systems with soft-water regeneration, the 

reserve capacity should be set to the volume of water used  

during regeneration to prevent hard water break-through. A 

Meter Immediate control will also start a regeneration cycle at  

the programmed regeneration time if a number of days equal to 

the regeneration day override pass before water usage depletes 

the calculated system capacity.

Meter Delayed Control

A Meter Delayed Control measures water usage and regener-

ates the system at the programmed regeneration time after the 

calculated system capacity is depleted. As with Meter Immediate 

systems, the control calculates the system capacity by dividing 

the unit capacity by the feedwater hardness and subtracting 

the reserve. The reserve should be set to insure that the system 

delivers treated water between the time the system capacity 

is depleted and the actual regeneration time. A Meter Delayed 

control will also start a regeneration cycle at the programmed 

regeneration time if a number of days equal to the regeneration 

day override pass before water usage depletes the calculated 

system capacity.

Time Clock Delayed Control

A Time Clock Delayed Control regenerates the system on a 

timed interval. The control will initiate a regeneration cycle at the 

programmed regeneration time when the number of days since 

the last regeneration equals the regeneration day override value.

Day of the Week Control

This control regenerates the system on a weekly schedule. The 

schedule is defined in Master Programming by setting each day 

to either “off” or “on.” The control will initiates a regeneration 

cycle on days that have been set to “on” at the specified  

regeneration time.

Control Operation During Regeneration

During regeneration, the control displays a special regeneration 

display. In this display, the control shows the current regeneration 

step number the valve is advancing to, or has reached, and the 

time remaining in that step. The step number that displays flash-

es until the valve completes driving to this regeneration step posi-

tion. Once all regeneration steps are complete the valve returns 

to service and resumes normal operation.
Pressing the Extra Cycle button during a regeneration cycle 

immediately advances the valve to the next cycle step position 

and resumes normal step timing.

Control Operation During Programming

The control only enters the Program Mode with the valve in ser-

vice. While in the Program Mode, the control continues to oper-

ate normally monitoring water usage and keeping all displays up 

to date. Control programming is stored in memory permanently, 

eliminating the need for battery backup power.

Manually Initiating a Regeneration

To occur that day at the next scheduled regeneration time:

1.  Press the Extra Cycle button. The service icon will flash to  

indicate that a regeneration is queued.

2.  To cancel a queued regeneration, press the Extra Cycle button.

To occur immediately:

1.  When controller is in service, press the Extra Cycle button for 

5 seconds on the main screen.

2.  The controller advances to Regeneration Cycle Step #1 

(Backwash), and begins programmed time count down.

3.  Press the Extra Cycle button once to advance valve to 

Regeneration Cycle Step #2 (Brine Draw/Rinse).

4.  Press the Extra Cycle button once to advance valve to 

Regeneration Cycle Step #3 (Rapid rinse).

5.  Press the Extra Cycle button once to advance valve to 

Regeneration Cycle Step #4 (Brine Refill).

6.  Press the Extra Cycle button once more to advance the valve 

back to in service.

NOTE:  If the unit is a filter or upflow, the cycle step order 

may change.

NOTE:  If regeneration occurs for any reason prior to the 

delayed regeneration time, the manual regeneration 

request shall be cleared.

Control Operation During A Power Failure

The SXT includes integral power backup. In the event of power 

failure, the control shifts into a power-saving mode. The control 

stops monitoring water usage, and the display and motor shut 

down, but it continues to keep track of the time and day for a 

minimum of 48 hours.
The system configuration settings are stored in a non-volatile 

memory and are stored indefinitely with or without line power. 

The Time of Day flashes when there has been a power failure. 

Press any button to stop the Time of Day from flashing.
If power fails while the unit is in regeneration, the control will save 

the current valve position before it shuts down. When power is 

restored, the control will resume the regeneration cycle from the 

point where power failed. Note that if power fails during a regen-

eration cycle, the valve will remain in it’s current position until 

power is restored. The valve system should include all required 

safety components to prevent overflows resulting from a power 

failure during regeneration.
The control will not start a new regeneration cycle without line 

power. If the valve misses a scheduled regeneration due to 

a power failure, it will queue a regeneration. Once power is 

restored, the control will initiate a regeneration cycle the next time 

that the Time of Day equals the programmed regeneration time. 

Typically, this means that the valve will regenerate one day after it 

was originally scheduled. If the treated water output is important 

and power interruptions are expected, the system should be 

setup with a sufficient reserve capacity to compensate for  

regeneration delays.

Summary of Contents for PWS10T Series

Page 1: ...IOM WQ PWS10T_15T Installation Operation and Maintenance 1 11 2 Commercial Water Softeners Series PWS10T PWS15T PWS10T Twin Alternating Systems PWS15T Twin Alternating Systems...

Page 2: ...ality components Simple programming corrosion resistant mineral tank s and an easy to service design ensures this system will be durable and easy to maintain Thank You The Watts Team Softened water pr...

Page 3: ...rheating of electronics may occur and ultraviolet rays from the sun may cause damage Operating ambient temperature 34 to 120 F 1 to 52 C Operating water pressure range 25 to 125psi 171 kPa to 8 6 bar...

Page 4: ...in is used to effectively exchange calcium and magnesium hardness cations for sodium cations in the water New or freshly regenerated ion exchange resin is saturated with sodium cations As calcium and...

Page 5: ...neration B System 7 2 Mineral Tanks 1 Meter Immediate Regeneration C System 14 2 8 Mineral Tanks 2 8 Meters Immediate Regeneration Progressive Flow Tank Staging GPM Threshold for Progressive Feature _...

Page 6: ...800 18 457 40 1016 500 227 PWS10T161E21 665 8 1692 665 8 1692 715 8 1819 161 8 409 331 8 841 18 457 40 1016 650 295 Series PWS15T MODEL NO DIMENSIONS WEIGHTS A B C D E F G in mm in mm in mm in mm in m...

Page 7: ...S15T171E21 16 x 65 4 0 80 lbs 24 x 41 600 120 K 80 K 60 24 25 40 15 25 7 0 PWS15T171F21 18 x 65 5 0 100 lbs 24 x 41 600 150 K 100 K 75 30 25 40 15 25 10 0 PWS15T171G21 21 x 62 7 0 100 lbs 24 x 50 800...

Page 8: ...be reached contact Watts customer service at 800 659 8400 Drain line flow controller for PWS10T Series is factory installed in valve s drain port Drain line flow controller for PWS15T may come loose...

Page 9: ...tubes during the loading of the media 4e Remove the funnel from the top of the tanks and plastic caps and tape from the top of the distributor tubes DO NOT PULL UP ON THE DISTRIBUTOR TUBES when remov...

Page 10: ...w arrow on the drain line flow controller must point towards the drain receptacle Only plumbing tape is allowed on the drain line flow controller fitting threads WARNING Operating a system without a d...

Page 11: ...backwash position then unplug the system Once water flow at the drain line is observed fully open the inlet valve and allow water to flow to drain for 15 minutes to flush the resin bed of any color I...

Page 12: ...roper drain connection follow all national state and local codes Do not construct drain line to elevations that exceed 4 feet above the control valve s drain port 11 The full weight of the piping and...

Page 13: ...5 Use factory supplied brine tubing Do not use smaller diameter tubing than what is supplied 16 Limit inlet pressure to not exceed maximum published operating pressure Installation Reference Notes For...

Page 14: ...14 Wiring Diagram SXT 9000 9500 42743 Rev A...

Page 15: ...e display will flash The parameter display will identify the destination cycle step BW BF RR etc and the data display will read Once the valve reaches the cycle step the display will stop flashing and...

Page 16: ...ontrol only enters the Program Mode with the valve in ser vice While in the Program Mode the control continues to oper ate normally monitoring water usage and keeping all displays up to date Control p...

Page 17: ...Times The time duration for each regeneration step Adjustable from OFF and 0 199 minutes NOTE If Othr is chosen under Valve Type then R1 R2 R3 etc will be displayed instead D1 D2 D3 D4 D5 D6 D7 Day o...

Page 18: ...ld the Extra Cycle button while powering up the unit This resets all of the parameters in the unit Check and verify the choices selected in Master Programming Mode 1 Display Format Display Code DF Thi...

Page 19: ...by V if volume capacity for a filter The Unit Capacity parameter is only available if the control type has been set to one of the metered options Use the Up and Down buttons to adjust the value as ne...

Page 20: ...eneration the reserve will change based on the old reserve capacity and the previous day s water usage This option setting is identified by CR in the upper left corner of the screen 12 Day Override Di...

Page 21: ...ting and move to the next day Note that the control requires at least one day to be set to ON If all 7 days are set to Off the unit will return to Day 1 until one or more days are set to ON Figure 17...

Page 22: ...used at a time Figure 21 Figure 22 ST Range 0 to total number of cycles minus 1 Figure 23 ET Range Start time to total of all cycles Figure 24 Figure 25 VO Range 1 to Total Gallon Capacity Figure 26...

Page 23: ...used by the unit since last installation or last reset SV Software Version Displays the software version installed on the controller NOTE Some items may not be shown depending on control configuratio...

Page 24: ...dentified by RC in the upper left corner of the screen Figure 30 Figure 32 Figure 33 SXT Diagnostics Cont d Figure 31 7 Press the Up button Use this display to view the Total Volume data This option i...

Page 25: ...4 sch 40 PVC that is the same height as the mineral tank and a length of 1 clear braided poly vinyl hose The hose must be long enough to reach the nearest floor drain Both of these can be acquired at...

Page 26: ...y discolor ation continue to flush the resin bed until water at the drain is clear During this flush water is flowing through both tanks so a separate flush for the second tank is not necessary 25 The...

Page 27: ...OP 7 2 7300136 C9092 FIBERGLASS MINERAL TANK 10X54 ALMOND W 2 5 8 TOP 7 2 7300139 C9094X FIBERGLASS MINERAL TANK 12X52 ALMOND W 2 5 8 TOP 7 2 7300143 C9098 FIBERGLASS MINERAL TANK 14X65 ALMOND W 4 8 T...

Page 28: ...8488 V2003 A MCH 02 PVC DRAIN FLOW CONTROL PVC 1 HOUSING F 12 20 GPM BUTTONS 2 1 68108568 V7102 3 5 FC BUTTON 3 5 GPM F 12 SOFTENER 2 1 68108569 V7103 05 FC BUTTON 5 0 GPM F 14 SOFTENER 2 1 68108571 V...

Page 29: ...02491 G2002B BRINE TANK 18X40 BLK EMPTY 11 1 68102494 G2003 BRINE TANK 24X41 BLK EMPTY 11 1 68102500 G2004 BRINE TANK 24X50 BLK EMPTY 11 1 68102511 G2009 BRINE TANK 30X50 BLK EMPTY 12 1 68102634 H7007...

Page 30: ...EAD ITEM NO QTY ORDERING CODE DESCRIPTION 1 1 7300344 K4562103 76 9000 POWERHEAD ASSEMBLY F 9000 9500 SXT W SXT CONTROLLER NO COVER OR TRANSFORMER 2 1 68104394 K4519674 TRANSFORMER 120V 24V USA 9 6VA...

Page 31: ...31 Replacement Parts SXT Controller Assembly SXT CONTROLLER ASSEMBLY ITEM NO QTY ORDERING CODE DESCRIPTION 1 1 7300304 K4542777 SXT CONTROLLER F 9000 9500 1...

Page 32: ...9100 W 5 GPM BLFC 1 5 GPM DLFC 9 1 68104595 K4560350 BRINE VALVE ASSEMBLY 9000 10 1 68104484 K4560022 100 BRINE FLOW CONTROL ASSEMBLY 1 00 GPM 3 8 F 9000 10 1 68104485 K4560022 25 BRINE FLOW CONTROL...

Page 33: ...512085 FLOW CONTROL WASHER 1 2 GPM F 6 TANK 13 1 68104110 K4512086 FLOW CONTROL WASHER 1 5 GPM F 8 TANK 13 1 68104111 K4512087 FLOW CONTROL WASHER 2 0 GPM F 9 TANK 13 1 68104112 K4512088 FLOW CONTROL...

Page 34: ...F UPPER 9500 NATURAL 3 1 68104544 K4560108 PISTON ASSEMBLY F UPPER 9500 4 1 68104565 K4560133 01 SEAL SPACER KIT F LOWER 9500 5 1 68104545 K4560109 PISTON ASSEMBLY F LOWER 9500 6 1 68104172 K4513577...

Page 35: ...510914 BL INJECTOR THROAT 2 BLUE 11 1 68104089 K4510914 G INJECTOR THROAT 4 GREEN 11 1 68104090 K4510914 R INJECTOR THROAT 0 RED 11 1 68104091 K4510914 W INJECTOR THROAT 1 WHITE 11 1 68104092 K4510914...

Page 36: ...2 INTERCONNECTING TUBE ASSEMBLY TO 2ND TANK F 9000 W 8 5 TUBES F 12 TANKS 2 1 68104288 K4515823 14 INTERCONNECTING TUBE ASSEMBLY TO 2ND TANK F 9000 W 10 5 TUBES F 14 TANKS 2 1 68104289 K4515823 16 INT...

Page 37: ...1 1 68104705 K4560715 16 INTERCONNECTING TUBE ASSEMBLY TO 2ND TANK F 9500 F 14 16 TANKS 1 1 68104706 K4560715 20 INTERCONNECTING TUBE ASSEMBLY TO 2ND TANK F 9500 F 18 20 TANKS 1 1 68104707 K4560715 24...

Page 38: ...0 NO FLOW CONTROLLER 1 1 68104503 K4560037 630 BRINE VALVE ASSEMBLY 1600 F 9500 W 1 0 GPM FLOW CONTROLLER 2 1 68104340 K4516960 BRINE TUBE 1600 F 9500 3 1 68104482 K4560020 25 BRINE FLOW CONTROL ASSEM...

Page 39: ...OW CONTROLLER 2 1 68104339 K4516959 BRINE TUBE 1700 F 9500 3 1 68104109 K4512085 FLOW CONTROL WASHER 1 2 GPM 3 1 68104110 K4512086 FLOW CONTROL WASHER 1 5 GPM 3 1 68104111 K4512087 FLOW CONTROL WASHER...

Page 40: ...16959 BRINE TUBE 1700 F 9500 3 1 68104109 K4512085 FLOW CONTROL WASHER 1 2 GPM 3 1 68104110 K4512086 FLOW CONTROL WASHER 1 5 GPM 3 1 68104111 K4512087 FLOW CONTROL WASHER 2 0 GPM 3 1 68104112 K4512088...

Page 41: ...Parts 3 4 Plastic Electronic Turbine Meter Assembly 3 4 PLASTIC ELECTRONIC TURBINE METER ASSEMBLY ITEM NO QTY ORDERING CODE DESCRIPTION 1 1 68104664 K4560626 METER ASSEMBLY 3 4 ELECTRONIC TURBINE W C...

Page 42: ...nic Turbine Meter Assembly 11 2 INCH PLASTIC ELECTRONIC TURBINE METER ASSEMBLY ITEM NO QTY ORDERING CODE DESCRIPTION 1 1 68104737 K4561560 13 METER ASSEMBLY 11 2 PLASTIC ELECTRONIC 2 2 68110410 K45415...

Page 43: ...sembly Stainless Steel For 9000 BYPASS VALVE ASSEMBLY STAINLESS STEEL FOR 9000 ITEM NO QTY ORDERING CODES DESCRIPTION 1 1 7300307 K4560040SS BYPASS VALVE ASSEMBLY 3 4 STAINLESS 1 1 7300308 K4560041SS...

Page 44: ...generation Inlet of control plugged due to foreign material broken loose from pipes by recent work done on plumbing system Remove piston and clean control valve Loss of mineral through drain line Air...

Page 45: ...erify that it functions correctly If the error re occurs unplug the unit and contact technical support 2 Regen Failure The system has not regenerated for more than 99 days or 7 days if the Control Typ...

Page 46: ...46 Water Softener Flow Diagrams 2 Backwash Position 1 In Service Position 3 Tanks Switching Position Meter Initiated Regeneration 4 Brine Draw Position 5 Slow Rinse...

Page 47: ...47 7 Brine Tank Fill Position 6 Rapid Rinse Position 8 In Service Position Tanks Switched Water Softener Flow Diagrams...

Page 48: ...48 Flow Data and Injector Draw Rates Down Flow 9000 9500 Injector Flow Data 1600 Series Injectors...

Page 49: ...49 Flow Data and Injector Draw Rates Down Flow 9500 Injector Flow Data 1600 1700 Series Injectors...

Page 50: ...0 Brine System Standard Size Color 0 Red 1 White 2 Blue 3 Yellow 4 Green Injector Nozzle and Throat Chart for 1600 1700 Brine Systems 1700 Brine System Standard Size Color 3C Yellow 4C Green 5C White...

Page 51: ...________________________________________________________________________________________________________ _______________________________________________________________________________________________...

Page 52: ...arranty period the Company will at its option replace or recondition the product without charge Disclaimer of Warranty THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN B...

Reviews: