System Installation

Pre-Installation Considerations

•  A minimum of 25psi of water pressure is required for regeneration 

valve to operate effectively.

•  A continuous 115 volt, 60 Hertz current supply is required. 

Make certain the current supply is always hot and cannot be 

turned off with another switch.

•  Condition of existing plumbing should be free from lime and 

iron buildup. Piping that is built up heavily with lime and/or iron 

should be replaced. If piping is clogged with iron, a separate 

iron filter unit should be installed ahead of the water softener.

•  The softener should be located close to a drain.
•  Always provide for the installation of a bypass valve.
•  The full weight of the plumbing system must be supported by 

pipe hangers or other means.

•  Do not install the system where it would block access to the water 

heater, main water shutoff, water meter, or electrical panels.

•  Install the system in a place where water damage is least likely 

to occur if a leak develops.

•  If applicable, use di-electric unions where dissimilar metals  

are present.

The main control valve and all plumbing connections have 

right-hand threads. Turn clockwise to install.

NOTICE

If O-ring lubricant is required, only use a silicone based 

compound formulated for potable water O-ring applications. 

Watts recommends Ordering Code #68102757 Silicone 

Lubricant. The use of other types of lubricants may attack 

the control’s plastic or rubber components. Petroleum-based 

lubricants can cause swelling in rubber parts, including  

O-rings and seals.

NOTICE

WARNING

!

Do not exceed water pressure of 125psi (8.6 bar). Do  

not exceed 110°F (43°C). Do not subject unit to freezing  

conditions.

General Installation Instructions

1.  Turn off water heater(s).
2.  Turn off the main water supply to the building and open a treated 

water faucet (cold and hot) to relieve any pressure within the 

plumbing system.

3.  Place the mineral tanks into their final position for installation. 

Make sure that the location is level and sturdy enough to  

support the weight of the system once it is in operation. 

4.  Unloaded mineral tanks will need to be loaded with resin and 

gravel media following the instructions below:

4a.  Inspect the distributor screens for damage, and make  

sure the screens are present before loading the mineral 

tanks with media. Before proceeding with installation, 

replace any damaged components immediately.

4b.  Cap the top open end of the distributor tubes with tape 

and plastic sheeting to keep all media and foreign debris 

from entering the distributor tubes. This cap must be 

secure and not come off during media loading.

4c.  Place the distributor tubes, screen end down, into the mineral 

tanks and center them in the bottom. The top of the dis-

tributor tubes should be flush with the top of the tanks. Test 

the tapes cap to make sure they can not come off during the 

media loading process.

4d.  Make sure the plastic and tape caps are secure to the top 

of the distributor tubes, place a funnel on the top of the 

tanks and load first the gravel then the softening resin into 

the tanks. The caps must not come off of the distributor 

tubes during the loading of the media.

4e.  Remove the funnel from the top of the tanks and plastic 

caps and tape from the top of the distributor tubes. DO 

NOT PULL UP ON THE DISTRIBUTOR TUBES when 

removing the caps. The distributor tube tops must remain 

flush with the top of the tank.

4f.   Clean any media from the threads and top of the mineral 

tanks. Media in the threads and on the O-ring sealing sur-

face of the tanks can cause tank thread damage and pre-

vent the control valve’s O-ring seal from sealing properly.

4g.  Lubricate the O-rings on the bottom of the control valve 

(distributor tube port O-ring and top of tank O-ring). Use 

nonpetroleum based silicone lubricant only. For PWS15T 

series systems press the factory suppled black upper  

diffuser into the base of the control valve and then repeat 

this step using the second tank adapter.

4h.  Place the control valve on top of the tank. When per-

forming this step, seat the top of the distributor tube inside 

the distributor port located on the bottom of the control valve 

first, then press the control valve down until the control valve 

threads come in contact with the tank threads. This ensures 

that the distributor tube is properly seated into the bottom 

of the control valve. Repeat this step using the other mineral 

tank and the second tank adapter. 

4i.   Tighten the control valve onto the tank with a clockwise 

rotation. Be careful not to cross thread the control valve to 

tank connection or over tighten it. A hand tight fit is appro-

priate for the control valve torque. DO NOT use a wrench. 

Tank or control valve damage could result. DO NOT apply 

thread sealant or plumbing tape on the control valve to 

tank threaded connection. Repeat this step using the other 

mineral tank and the second tank adapter.

4j.  Install the interconnecting tube assembly from the control 

valve to the second tank adapter. For PWS10T series sys-

tems tighten clips with screws provided using a nut driver. 

For PWS15T series systems tighten flanges (X2) to control 

valve and second tank adapter using a wrench.

5.    

Meter Installation:

 On PWS10T series systems the meter is 

pre-installed by the factory. Proceed to installation step 7. For 

PWS15T series systems, apply a suitable thread sealant to the 

male threads of the flow meter and with the meter’s direction of 

flow arrow pointing in the direction of water flow, install the meter 

directly into the outlet port of the system control valve. 

6.  For PWS15T series systems, rotate meter clockwise to tighten, 

by gripping the meter on the end connector that attaches to the 

control valve with a wrench, and continue to tighten the flow meter 

end connector until tight. Then rotate plastic meter body so the 

meter cable can be aligned and inserted into the meter’s cable 

port. DO NOT grip on the plastic meter body with the wrench 

when installing the flow meter. 

7.  For PWS10T series systems, attach bypass valve assembly using 

clips and screws provided. Hand tighten screws with a nut driver.

If 4" X 21/2" PVC tank bushings are included with the system 

to adapt the control valve base to a larger control valve tank 

connection, ensure the bushings are tightened, fully hand 

tight, into the tanks at this time. 

NOTICE

Installation diagrams and additional details are available on 

pages 12-13 of this manual.

NOTICE

Summary of Contents for PWS10T Series

Page 1: ...IOM WQ PWS10T_15T Installation Operation and Maintenance 1 11 2 Commercial Water Softeners Series PWS10T PWS15T PWS10T Twin Alternating Systems PWS15T Twin Alternating Systems...

Page 2: ...ality components Simple programming corrosion resistant mineral tank s and an easy to service design ensures this system will be durable and easy to maintain Thank You The Watts Team Softened water pr...

Page 3: ...rheating of electronics may occur and ultraviolet rays from the sun may cause damage Operating ambient temperature 34 to 120 F 1 to 52 C Operating water pressure range 25 to 125psi 171 kPa to 8 6 bar...

Page 4: ...in is used to effectively exchange calcium and magnesium hardness cations for sodium cations in the water New or freshly regenerated ion exchange resin is saturated with sodium cations As calcium and...

Page 5: ...neration B System 7 2 Mineral Tanks 1 Meter Immediate Regeneration C System 14 2 8 Mineral Tanks 2 8 Meters Immediate Regeneration Progressive Flow Tank Staging GPM Threshold for Progressive Feature _...

Page 6: ...800 18 457 40 1016 500 227 PWS10T161E21 665 8 1692 665 8 1692 715 8 1819 161 8 409 331 8 841 18 457 40 1016 650 295 Series PWS15T MODEL NO DIMENSIONS WEIGHTS A B C D E F G in mm in mm in mm in mm in m...

Page 7: ...S15T171E21 16 x 65 4 0 80 lbs 24 x 41 600 120 K 80 K 60 24 25 40 15 25 7 0 PWS15T171F21 18 x 65 5 0 100 lbs 24 x 41 600 150 K 100 K 75 30 25 40 15 25 10 0 PWS15T171G21 21 x 62 7 0 100 lbs 24 x 50 800...

Page 8: ...be reached contact Watts customer service at 800 659 8400 Drain line flow controller for PWS10T Series is factory installed in valve s drain port Drain line flow controller for PWS15T may come loose...

Page 9: ...tubes during the loading of the media 4e Remove the funnel from the top of the tanks and plastic caps and tape from the top of the distributor tubes DO NOT PULL UP ON THE DISTRIBUTOR TUBES when remov...

Page 10: ...w arrow on the drain line flow controller must point towards the drain receptacle Only plumbing tape is allowed on the drain line flow controller fitting threads WARNING Operating a system without a d...

Page 11: ...backwash position then unplug the system Once water flow at the drain line is observed fully open the inlet valve and allow water to flow to drain for 15 minutes to flush the resin bed of any color I...

Page 12: ...roper drain connection follow all national state and local codes Do not construct drain line to elevations that exceed 4 feet above the control valve s drain port 11 The full weight of the piping and...

Page 13: ...5 Use factory supplied brine tubing Do not use smaller diameter tubing than what is supplied 16 Limit inlet pressure to not exceed maximum published operating pressure Installation Reference Notes For...

Page 14: ...14 Wiring Diagram SXT 9000 9500 42743 Rev A...

Page 15: ...e display will flash The parameter display will identify the destination cycle step BW BF RR etc and the data display will read Once the valve reaches the cycle step the display will stop flashing and...

Page 16: ...ontrol only enters the Program Mode with the valve in ser vice While in the Program Mode the control continues to oper ate normally monitoring water usage and keeping all displays up to date Control p...

Page 17: ...Times The time duration for each regeneration step Adjustable from OFF and 0 199 minutes NOTE If Othr is chosen under Valve Type then R1 R2 R3 etc will be displayed instead D1 D2 D3 D4 D5 D6 D7 Day o...

Page 18: ...ld the Extra Cycle button while powering up the unit This resets all of the parameters in the unit Check and verify the choices selected in Master Programming Mode 1 Display Format Display Code DF Thi...

Page 19: ...by V if volume capacity for a filter The Unit Capacity parameter is only available if the control type has been set to one of the metered options Use the Up and Down buttons to adjust the value as ne...

Page 20: ...eneration the reserve will change based on the old reserve capacity and the previous day s water usage This option setting is identified by CR in the upper left corner of the screen 12 Day Override Di...

Page 21: ...ting and move to the next day Note that the control requires at least one day to be set to ON If all 7 days are set to Off the unit will return to Day 1 until one or more days are set to ON Figure 17...

Page 22: ...used at a time Figure 21 Figure 22 ST Range 0 to total number of cycles minus 1 Figure 23 ET Range Start time to total of all cycles Figure 24 Figure 25 VO Range 1 to Total Gallon Capacity Figure 26...

Page 23: ...used by the unit since last installation or last reset SV Software Version Displays the software version installed on the controller NOTE Some items may not be shown depending on control configuratio...

Page 24: ...dentified by RC in the upper left corner of the screen Figure 30 Figure 32 Figure 33 SXT Diagnostics Cont d Figure 31 7 Press the Up button Use this display to view the Total Volume data This option i...

Page 25: ...4 sch 40 PVC that is the same height as the mineral tank and a length of 1 clear braided poly vinyl hose The hose must be long enough to reach the nearest floor drain Both of these can be acquired at...

Page 26: ...y discolor ation continue to flush the resin bed until water at the drain is clear During this flush water is flowing through both tanks so a separate flush for the second tank is not necessary 25 The...

Page 27: ...OP 7 2 7300136 C9092 FIBERGLASS MINERAL TANK 10X54 ALMOND W 2 5 8 TOP 7 2 7300139 C9094X FIBERGLASS MINERAL TANK 12X52 ALMOND W 2 5 8 TOP 7 2 7300143 C9098 FIBERGLASS MINERAL TANK 14X65 ALMOND W 4 8 T...

Page 28: ...8488 V2003 A MCH 02 PVC DRAIN FLOW CONTROL PVC 1 HOUSING F 12 20 GPM BUTTONS 2 1 68108568 V7102 3 5 FC BUTTON 3 5 GPM F 12 SOFTENER 2 1 68108569 V7103 05 FC BUTTON 5 0 GPM F 14 SOFTENER 2 1 68108571 V...

Page 29: ...02491 G2002B BRINE TANK 18X40 BLK EMPTY 11 1 68102494 G2003 BRINE TANK 24X41 BLK EMPTY 11 1 68102500 G2004 BRINE TANK 24X50 BLK EMPTY 11 1 68102511 G2009 BRINE TANK 30X50 BLK EMPTY 12 1 68102634 H7007...

Page 30: ...EAD ITEM NO QTY ORDERING CODE DESCRIPTION 1 1 7300344 K4562103 76 9000 POWERHEAD ASSEMBLY F 9000 9500 SXT W SXT CONTROLLER NO COVER OR TRANSFORMER 2 1 68104394 K4519674 TRANSFORMER 120V 24V USA 9 6VA...

Page 31: ...31 Replacement Parts SXT Controller Assembly SXT CONTROLLER ASSEMBLY ITEM NO QTY ORDERING CODE DESCRIPTION 1 1 7300304 K4542777 SXT CONTROLLER F 9000 9500 1...

Page 32: ...9100 W 5 GPM BLFC 1 5 GPM DLFC 9 1 68104595 K4560350 BRINE VALVE ASSEMBLY 9000 10 1 68104484 K4560022 100 BRINE FLOW CONTROL ASSEMBLY 1 00 GPM 3 8 F 9000 10 1 68104485 K4560022 25 BRINE FLOW CONTROL...

Page 33: ...512085 FLOW CONTROL WASHER 1 2 GPM F 6 TANK 13 1 68104110 K4512086 FLOW CONTROL WASHER 1 5 GPM F 8 TANK 13 1 68104111 K4512087 FLOW CONTROL WASHER 2 0 GPM F 9 TANK 13 1 68104112 K4512088 FLOW CONTROL...

Page 34: ...F UPPER 9500 NATURAL 3 1 68104544 K4560108 PISTON ASSEMBLY F UPPER 9500 4 1 68104565 K4560133 01 SEAL SPACER KIT F LOWER 9500 5 1 68104545 K4560109 PISTON ASSEMBLY F LOWER 9500 6 1 68104172 K4513577...

Page 35: ...510914 BL INJECTOR THROAT 2 BLUE 11 1 68104089 K4510914 G INJECTOR THROAT 4 GREEN 11 1 68104090 K4510914 R INJECTOR THROAT 0 RED 11 1 68104091 K4510914 W INJECTOR THROAT 1 WHITE 11 1 68104092 K4510914...

Page 36: ...2 INTERCONNECTING TUBE ASSEMBLY TO 2ND TANK F 9000 W 8 5 TUBES F 12 TANKS 2 1 68104288 K4515823 14 INTERCONNECTING TUBE ASSEMBLY TO 2ND TANK F 9000 W 10 5 TUBES F 14 TANKS 2 1 68104289 K4515823 16 INT...

Page 37: ...1 1 68104705 K4560715 16 INTERCONNECTING TUBE ASSEMBLY TO 2ND TANK F 9500 F 14 16 TANKS 1 1 68104706 K4560715 20 INTERCONNECTING TUBE ASSEMBLY TO 2ND TANK F 9500 F 18 20 TANKS 1 1 68104707 K4560715 24...

Page 38: ...0 NO FLOW CONTROLLER 1 1 68104503 K4560037 630 BRINE VALVE ASSEMBLY 1600 F 9500 W 1 0 GPM FLOW CONTROLLER 2 1 68104340 K4516960 BRINE TUBE 1600 F 9500 3 1 68104482 K4560020 25 BRINE FLOW CONTROL ASSEM...

Page 39: ...OW CONTROLLER 2 1 68104339 K4516959 BRINE TUBE 1700 F 9500 3 1 68104109 K4512085 FLOW CONTROL WASHER 1 2 GPM 3 1 68104110 K4512086 FLOW CONTROL WASHER 1 5 GPM 3 1 68104111 K4512087 FLOW CONTROL WASHER...

Page 40: ...16959 BRINE TUBE 1700 F 9500 3 1 68104109 K4512085 FLOW CONTROL WASHER 1 2 GPM 3 1 68104110 K4512086 FLOW CONTROL WASHER 1 5 GPM 3 1 68104111 K4512087 FLOW CONTROL WASHER 2 0 GPM 3 1 68104112 K4512088...

Page 41: ...Parts 3 4 Plastic Electronic Turbine Meter Assembly 3 4 PLASTIC ELECTRONIC TURBINE METER ASSEMBLY ITEM NO QTY ORDERING CODE DESCRIPTION 1 1 68104664 K4560626 METER ASSEMBLY 3 4 ELECTRONIC TURBINE W C...

Page 42: ...nic Turbine Meter Assembly 11 2 INCH PLASTIC ELECTRONIC TURBINE METER ASSEMBLY ITEM NO QTY ORDERING CODE DESCRIPTION 1 1 68104737 K4561560 13 METER ASSEMBLY 11 2 PLASTIC ELECTRONIC 2 2 68110410 K45415...

Page 43: ...sembly Stainless Steel For 9000 BYPASS VALVE ASSEMBLY STAINLESS STEEL FOR 9000 ITEM NO QTY ORDERING CODES DESCRIPTION 1 1 7300307 K4560040SS BYPASS VALVE ASSEMBLY 3 4 STAINLESS 1 1 7300308 K4560041SS...

Page 44: ...generation Inlet of control plugged due to foreign material broken loose from pipes by recent work done on plumbing system Remove piston and clean control valve Loss of mineral through drain line Air...

Page 45: ...erify that it functions correctly If the error re occurs unplug the unit and contact technical support 2 Regen Failure The system has not regenerated for more than 99 days or 7 days if the Control Typ...

Page 46: ...46 Water Softener Flow Diagrams 2 Backwash Position 1 In Service Position 3 Tanks Switching Position Meter Initiated Regeneration 4 Brine Draw Position 5 Slow Rinse...

Page 47: ...47 7 Brine Tank Fill Position 6 Rapid Rinse Position 8 In Service Position Tanks Switched Water Softener Flow Diagrams...

Page 48: ...48 Flow Data and Injector Draw Rates Down Flow 9000 9500 Injector Flow Data 1600 Series Injectors...

Page 49: ...49 Flow Data and Injector Draw Rates Down Flow 9500 Injector Flow Data 1600 1700 Series Injectors...

Page 50: ...0 Brine System Standard Size Color 0 Red 1 White 2 Blue 3 Yellow 4 Green Injector Nozzle and Throat Chart for 1600 1700 Brine Systems 1700 Brine System Standard Size Color 3C Yellow 4C Green 5C White...

Page 51: ...________________________________________________________________________________________________________ _______________________________________________________________________________________________...

Page 52: ...arranty period the Company will at its option replace or recondition the product without charge Disclaimer of Warranty THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN B...

Reviews: