How to Use the Quick-Connect Fittings on the RO Module

To make a connection, the tube is simply pushed into the fitting . 

Place a piece of tape 

1

/

2

" from end of tube to indicate how far the 

tube should be inserted . The unique Quick-Connect locking system 

holds the tube firmly in place without deforming it or restricting flow .

Cut the tube square . It is essential that the outside diameter be free of score marks 

and that burrs and sharp edges be removed before inserting into fitting .

Fitting grips before it seals . Ensure tube is pushed into the tube stop .

Push the tube into the fitting, to the tube stop . The collet (gripper) has stainless 

steel teeth which hold the tube firmly in position while the O-ring provides a perma-

nent leak proof seal .

Pull on the tube to check that it is secure . It is a good practice to test the system 

prior to leaving site and /or before use .

To disconnect, ensure the system is depressurized before removing the tube . Push 

in collet squarely against face of fitting . With the collet held in this position, the tube 

can be removed . The fitting can then be reused .

Summary of Contents for PWRO5MAN

Page 1: ...n 5 Drain Saddle Installation 6 Green Tube Connection 6 Reverse Osmosis Module Mounting 6 Red Tube Connection 6 Check Air Pressure in the Tank 7 Tank Elbow Installation 7 Blue Tube Connection 7 Blue T...

Page 2: ...arsenic and lead Reverse osmosis uses a semi permeable membrane however by applying pressure across the membrane it concentrates contami nants like a strainer on one side of the membrane producing cry...

Page 3: ...rench Sharp Knife 1 2 5 8 Open End Wrenches Phillips Screw Driver Needle Nose Pliers Adjustable Pliers Electric Drill 1 8 Drill Bit 1 4 Drill Bit 3 8 Drill Bit Hardness Recommended hardness not to exc...

Page 4: ...be removed before inserting into fitting Fitting grips before it seals Ensure tube is pushed into the tube stop Push the tube into the fitting to the tube stop The collet gripper has stainless steel...

Page 5: ...tubing and toggle bolt down through the 1 mounting hole in the sink Ensure that the soft rubber gasket is uniformly positioned in between the base of the faucet and the top of the sink Step B Align th...

Page 6: ...cle bracket with opening 2 Screws 1 Foam gasket 2 Nuts for screws 1 Semicircle bracket Step B The small square black foam gasket with a circle cut out of the middle must be applied to the inside of th...

Page 7: ...rader valve that is located on the lower side of the tank behind the blue plastic cap Step A Turn off the incoming water supply to the RO by turning the knob on the Adapt A Valve clockwise until it st...

Page 8: ...er tempera ture and water pressure Note During the fill period you may hear water trickling due to the Reverse Osmosis Process Step D After the Tank has filled open the RO Faucet to flush the tank com...

Page 9: ...arbon Block Filters 1 Final Inline Filter Note Sanitizing of unit is recommended Step A Perform Steps A through E in the 6 Month System Main tenance Note If not sanitizing the system skip to Step H St...

Page 10: ...ote A water sample may be sent to Watts for a free diagno sis of your membrane performance To send a water sample use two 2 clean containers and fill cup of tap water in one container and cup of rever...

Page 11: ...et or drain Air gap faucet Location of drain saddle Higher capacity membrane High water pressure Inherent sound with air gap faucets See diagram for proper location of drain saddle Normal with high ca...

Page 12: ...lso called chloramine where it does convert trivalent arsenic to pentavalent arsenic may not con vert all the trivalent arsenic in to pentavalent arsenic If you get your water from a public water util...