background image

5

Adapt-A-Valve™ Installation

Verify contents prior to installation:

( 1 ) - Plastic Adapt-a-Valve™ & Black Collet 

( 1 ) - Brass Adapter no washer 

( 1 ) - Brass Adapter with black washer  

( 1 ) - White rubber washer

Water supply line to the system must be from the cold water 

supply line only. Hot water will severely damage your system.
WARNING:  Do not use Teflon tape with the Adapt-A-Valve™. 

For 

3

8

" Configuration  

For 

1

2

" Configuration  

Step A -

  Turn off the cold water supply to the faucet by turning the 

angle stop valve completely off . 

Step B -

  Open cold water sink faucet to relieve pressure . 

Step C -

  Choosing the configuration that fits your plumbing, at-

tach the Adapt-A-Valve™ as illustrated in the four photos 

above .

STEP 2

Watts Chrome Top Mount  

Faucet Installation 

Gather and identify the faucet pieces.

Step A -

  Remove faucet base and faucet spout from their respective 

plastic bags . From above the sink, feed the faucet tubing 

and toggle bolt down through the 1¼" mounting hole in 

the sink . Ensure that the soft rubber gasket is uniformly 

positioned in between the base of the faucet and the top of 

the sink .

Step B -

  Align the faucet base so that the handle is on the right side 

and the base is sitting flush on the sink top . Turn the handle 

down (towards you) to the “ON” position to reveal the 

tightening screw (located where the spout will be inserted) . 

Using a phillips head screwdriver, turn the screw clockwise 

until the toggle bolt secures the faucet base snug onto the 

sink top . 

Step C -

  Once the faucet base is securely fastened to the sink top, 

insert the faucet spout into the faucet base until it is fully 

seated . Turn the handle up (away from you) to the “OFF” 

position .

Step D -

   Locate 

3

8

" blue tubing in parts bag, connect open end of 

the 

3

8

" tubing to the quick-connect fitting located on the 

faucet shank .

MiNiMUM

MaxiMUM

Mounting Hole Size

1"

1

1

4

"

Torque on Toggle Bolt

5 lb.in. (max)

STEP 3

Hot

Supply

Cold

Supply

Hot

Supply

Cold

Supply

(With Brass Fittings) 

* Insert White Washer

(Without Brass Fittings) 

1

2

" Configuration

Summary of Contents for PWRO5MAN

Page 1: ...n 5 Drain Saddle Installation 6 Green Tube Connection 6 Reverse Osmosis Module Mounting 6 Red Tube Connection 6 Check Air Pressure in the Tank 7 Tank Elbow Installation 7 Blue Tube Connection 7 Blue T...

Page 2: ...arsenic and lead Reverse osmosis uses a semi permeable membrane however by applying pressure across the membrane it concentrates contami nants like a strainer on one side of the membrane producing cry...

Page 3: ...rench Sharp Knife 1 2 5 8 Open End Wrenches Phillips Screw Driver Needle Nose Pliers Adjustable Pliers Electric Drill 1 8 Drill Bit 1 4 Drill Bit 3 8 Drill Bit Hardness Recommended hardness not to exc...

Page 4: ...be removed before inserting into fitting Fitting grips before it seals Ensure tube is pushed into the tube stop Push the tube into the fitting to the tube stop The collet gripper has stainless steel...

Page 5: ...tubing and toggle bolt down through the 1 mounting hole in the sink Ensure that the soft rubber gasket is uniformly positioned in between the base of the faucet and the top of the sink Step B Align th...

Page 6: ...cle bracket with opening 2 Screws 1 Foam gasket 2 Nuts for screws 1 Semicircle bracket Step B The small square black foam gasket with a circle cut out of the middle must be applied to the inside of th...

Page 7: ...rader valve that is located on the lower side of the tank behind the blue plastic cap Step A Turn off the incoming water supply to the RO by turning the knob on the Adapt A Valve clockwise until it st...

Page 8: ...er tempera ture and water pressure Note During the fill period you may hear water trickling due to the Reverse Osmosis Process Step D After the Tank has filled open the RO Faucet to flush the tank com...

Page 9: ...arbon Block Filters 1 Final Inline Filter Note Sanitizing of unit is recommended Step A Perform Steps A through E in the 6 Month System Main tenance Note If not sanitizing the system skip to Step H St...

Page 10: ...ote A water sample may be sent to Watts for a free diagno sis of your membrane performance To send a water sample use two 2 clean containers and fill cup of tap water in one container and cup of rever...

Page 11: ...et or drain Air gap faucet Location of drain saddle Higher capacity membrane High water pressure Inherent sound with air gap faucets See diagram for proper location of drain saddle Normal with high ca...

Page 12: ...lso called chloramine where it does convert trivalent arsenic to pentavalent arsenic may not con vert all the trivalent arsenic in to pentavalent arsenic If you get your water from a public water util...

Page 13: ...ION 1 7100454 Gac Post Filter 2 7100446 Carbon Block 3 7100331 Sediment Filter 4 7300043 Manifold Bowl 5 7300046 Manifold Membrane Vessel 6 7300058 O Ring For Manifold Bowl 7 7300057 O Ring For Membra...

Page 14: ...Date of Purchase Date of Install Installed by Date 1st stage Sediment 6 months 2nd stage Carbon 6 months 3rd stage Carbon 6 months Final Filter Carbon 1 year TFM Membrane 2 5 years Notes Service Reco...

Page 15: ...15...

Page 16: ...arranties are exclusive and are the only remedies for breach of warranty EXCEPT FOR THE APPLICABLE PRODUCT WARRANTY IF ANY WATTS MAKES NO OTHER WARRANTIES EXPRESS OR IMPLIED TO THE FULLEST EXTENT PERM...

Reviews: