background image

Operation & Maintenance Manual 

AquaSolve

®

IOM-ASM1465TM_M1665TM

Page 7 of 7

Technical Support

  •  (800) 433-5654  •  Mon-Fri, 8 am - 5 pm EST

Limited Warranty

PVI warrants its AquaSolve tank system as follows: 

•  AquaSolve tank system is warranted to be free of defects in materi-

als and workmanship for 5 years from the date of original shipment.

•  The AquaSolve media is warranted for performance for a period of 

2 years from the date of the original installation when installed and 
oper-ated in accordance with the instructions in the corresponding 
Installation and Operation Manual. PVI warrants its AquaSolve car-
tridge systems as follows:

•  The AquaSolve cartridge system is warranted to be free of defects 

in materials and workmanship for 1 year from the date of original 
shipment.

•  AquaSolve cartridges are warranted for performance for a period 

of one year from the date of original installation when installed and 
operated in accordance with the instructions in the corresponding 
Installation and Operation Manual.

•  Carbon replacement filter cartridges are not warranted to perform for 

any period of time because the service life of replacement carbon 
filter cartridges varies significantly with local water conditions and 
volume.

1.  AquaSolve system must be installed in applications with municipally 

supplied water adhering to EPA guidelines with the exception of 
oil and grease, copper, phosphate, silca and chlorine. See copper 
warnings on page 2 and condition number 5 below.

Parts List

Item

Qty.

PVI Part #

Description

1

1

149692

Tank head only basket  
assembly is separate basket

2

2

144065

Flex hose 2” x 12”

3

1

144066

Riser and bottom  
distributor assembly

4a

1

144067

14” X 65” tank 4” top

4b

1

144068

16” X 65” tank 4” top

2.  Any component failure must not result from abuse, fire, freezing or 

other acts of nature, violence, or improper installation.

3.  Equipment must be installed and operated in compliance with the 

local plumbing codes and on an approved water supply.

4.  Equipment is limited to use at water pressures and temperatures that 

do not exceed our published specifications.

5.  Water supply must not exceed 2.0 PPM chlorine. For water supply 

exceeding 2.0 PPM chlorine, pretreatment is required. (Please con-
tact your water treatment specialist.)

6.  Information, including model number, serial number, and date of 

installation, must be provided for any claims pertaining to equipment 
in warranty.

7.  Defective parts are subject to inspection by either PVI or any autho-

rized representative before final commitment of warranty adjustment 
is made.

8.  PVI reserves the right to make changes or substitutions in parts or 

equipment with material of equal quality or value and of then current 
production.

Limitations

 

Our obligation under this warranty with respect to the tank or valve is 
limited to furnishing a replacement for, or at our option, repairing any 
part or parts to our satisfaction that prove defective within the warranty 
period stated above. Such replacement parts will be delivered to the 
owner F.O.B. nearest factory, at no cost, excluding freight and local 
labor charges, if any. Our obligation under this warranty with respect to 
the AquaSolve media will be limited to furnishing a replacement for the 
media within two years from date of original installation. Such replace-
ment media will be delivered to the owner F.O.B. nearest factory, at no 
cost, excluding freight and local labor charges, if any. Damage to the 
media due to chlorine, other oxidizers or fouling caused by local water 
conditions or any other operation outside of the limits shown under 
Specifications, is not covered by this warranty. 

The warranty set forth herein is given expressly and is the only warranty 
given by PVI company with respect to the product. PVI company makes 
no other warranties, express or implied. PVI company hereny specifically 
disclaims all other warranties, express or implied, including but not limit-
ed to the implied warranties of merchantablity and fitness for a particular 
purpose. 

The remedy described under this warranty shall constitute the sole and 
exclusive remedy for breach of warranty, and PVI company shall not 
be responsible for any incidental, special or consequential damages, 
including without limitation, freight, handling, lost profits or the cost of 
repairing or replacing other property which is damaged if this product 
does not work properly, other costs resulting from labor charges, delays, 
vandalism, negligence, fouling caused by foreign material, damage from 
adverse water conditions, chemical, or any other circumstances over 
which PVI company has no control. This warranty shall be invalidated 
by any abuse, misuse, misap-plication or improper installation of the 
product.

Some states do not allow limitations on how long an implied warranty 
lasts, and some states do not allow the exclusion or limitation of inciden-
tal or consequential damages. Therefore the above limitations may not 
apply to you. This warranty gives you specific legal rights, and you may 
have other rights that vary from state to state. You should consult appli-
cable state laws to determine your rights. So far as is consistent with 
applicable state law, any implied warranties that may not be disclaimed, 
including the implied warrantied of merchanability and fitness for a par-
ticular purpose, are limited in duration to the applicable warranty periods 
stated above.

Summary of Contents for PVI AquaSolve M8414TM-COM

Page 1: ...335 9531 Toll Free 800 784 8326 PVI com Technical Support 800 433 5654 Mon Fri 8 am 5 pm EST Manufacturing ASME Commercial Water Heaters Since 1961 IOM ASM1465TM_M1665TM Important Read this Manual BE...

Page 2: ...ashing chemistry will like wise require adjustments AquaSolve Benefits Chemical free scale prevention and protection converts hardness minerals to harmless inactive microscopic crystals making AquaSol...

Page 3: ...aSolve there are some unique requirements for using AquaSolve in conjunction with other forms of water treatment 1 AquaSolve must be the last stage in the treatment chain Do not install any filters af...

Page 4: ...While silica tends to have a less significant effect on scale formation than other minerals it can act as a binder that makes water spots and scale residue outside the plumbing system difficult to re...

Page 5: ...tall Piping Connect the inlet and outlet plumbing according to your preferences and any applicable local codes Include sample drain ports with hose bibb connec tions on the inlet and outlet piping to...

Page 6: ...the media and allow the water to go down the drain 10 Try not to be too aggressive when extracting the media You need to take it out in small bites If you let the whole pipe hose fill with media it wi...

Page 7: ...es or substitutions in parts or equipment with material of equal quality or value and of then current production Limitations Our obligation under this warranty with respect to the tank or valve is lim...

Reviews: