background image

Operation & Maintenance Manual 

AquaSolve

®

IOM-ASM1465TM_M1665TM

Page 4 of 7

Technical Support

  •  (800) 433-5654  •  Mon-Fri, 8 am - 5 pm EST

Equipment Specifications

AquaSolve systems are complete, selfcontained, 
loaded with media, and ready to use. A simple 
inlet and outlet connection is all that is required for 
installation. Please review operating pressures, tem-
peratures and water chemistry limitations to ensure 
compatibility.

Feed Water Chemistry Requirements

pH

6.5 to 8.5

Hardness (max.)

30 grains

Water Pressure

15 psi to 150 psi

Temperature

40ºF to 100ºF (5ºC to 38ºC)

Chlorine

<2 ppm

Iron (max.)

0.3 mg/l*

Manganese (max.)

0.05 mg/l**

Copper (max.)

1.3 ppm**

Oil & H2S

Remove prior to AquaSolve

Phosphates

Remove prior to AquaSolve

Silica (max.)

20 ppm***

TDS

1500 mg/l****

*Iron and Manganese

Just as with conventional water softening media, AquaSolve needs 
to be protected from excess levels of certain metals that can eas-
ily coat the active surface, reducing its effectiveness over time. 
Public water supplies rarely, if ever, present a problem, but if the 
water supply is from a private well, confirm that the levels of iron 
(Fe) and manganese (Mn) are less than 0.3 mg/L and 0.05 mg/L
respectively.

**Copper

Pursuant to the EPA drinking water standards, the copper concen-
tration permitted is up to 1.3 ppm. Typically originating from new 
copper plumbing, high levels of copper can foul AquaSolve media. 
For applications with copper concentration greater than 1.3 ppm, 
please contact PVI Technical Support at 1-800-433-5654.  
To further minimize any problem with excess  
copper, avoid applying excessive flux on the  
inner surfaces of the pipe and use a low- 
corrosivity water soluble flux listed under the 
ASTM B813 standard.

***Silica

AquaSolve media does not reduce silica scaling.  
While silica tends to have a less significant effect  
on scale formation than other minerals, it can  
act as a binder that makes water spots and  
scale residue outside the plumbing system  
difficult to remove. This 20 ppm limitation is for  
aesthetic purposes.

NOTICE

Water known to have heavy loads of dirt and debris may require 
prefiltration prior to AquaSolve.
*See note about iron, manganese and copper (bottom left). 
Systems using AquaSolve technology prevent hard water scale 
formation inside the plumbing system at influent hardness levels 
of 30 grains per gallon of calcium carbonate and less. Due to vari-
ances in water chemistry, certain aesthetic conditions external of 
the plumbing system may not be attained. AquaSolve is designed 
for the treatment of potable water that meets the requirements of 
the current USEPA Safe Drinking Water Act.

NOTICE

Mechanical Specifications

Model

M8414TM-COM

M8416TM-COM

Dry Weight  
lbs/kg

124 / 56

145 / 66

Service Weight 
lbs/kg

458 / 208

550 / 250

Inlet/Outlet
Connection

2” FNPT

2” FNPT

Replacement Media

M8414-COM-RM  Replace media every 3 years
M8416-COM-RM  Replace media every 3 years

Dimensions 

(nominal - inches)

Model

M8414TM-COM

M8416TM-COM

a

14

16

b

73.1

73.1

Max. Service Flow (gpm) vs. Water Temp. (ºF)

System

40

º

45

º

50

º

55

º

60

º

65

º

70

º

M8414TM

40

44

48

50

50

50

50

M8416TM

45

51

56

59

63

69

75

Intermittent Duty Systems

M8414TM-COM

50 gpm at all temperatures

M8416TM-COM

75 gpm at all temperatures

Max. Flow Rate***

M8414TM-COM

50 gpm

189 lpm

M8416TM-COM

75 gpm

284 lpm

***Exceeding maximum flow can reduce effectiveness and void   
   warranty.
Pressure drop at peak flow rate is less than 22 psi.
Pressure drop reading taken with inlet and outlet gauges installed 
at a common elevation and 80 degree feed water.

****All other contaminants must meet the requirements of the 
USEPA Safe Drinking Water Act. Specific Mineral and Metal 
MCLs, identified in Watts’ published Feed Water Chemistry 
Requirements, supersede the USEPA SDWA.

Summary of Contents for PVI AquaSolve M8414TM-COM

Page 1: ...335 9531 Toll Free 800 784 8326 PVI com Technical Support 800 433 5654 Mon Fri 8 am 5 pm EST Manufacturing ASME Commercial Water Heaters Since 1961 IOM ASM1465TM_M1665TM Important Read this Manual BE...

Page 2: ...ashing chemistry will like wise require adjustments AquaSolve Benefits Chemical free scale prevention and protection converts hardness minerals to harmless inactive microscopic crystals making AquaSol...

Page 3: ...aSolve there are some unique requirements for using AquaSolve in conjunction with other forms of water treatment 1 AquaSolve must be the last stage in the treatment chain Do not install any filters af...

Page 4: ...While silica tends to have a less significant effect on scale formation than other minerals it can act as a binder that makes water spots and scale residue outside the plumbing system difficult to re...

Page 5: ...tall Piping Connect the inlet and outlet plumbing according to your preferences and any applicable local codes Include sample drain ports with hose bibb connec tions on the inlet and outlet piping to...

Page 6: ...the media and allow the water to go down the drain 10 Try not to be too aggressive when extracting the media You need to take it out in small bites If you let the whole pipe hose fill with media it wi...

Page 7: ...es or substitutions in parts or equipment with material of equal quality or value and of then current production Limitations Our obligation under this warranty with respect to the tank or valve is lim...

Reviews: