background image

Transformer Colors

Primary Voltage

Lead Colors

120 Volts

Black & White

208 Volts

Black & Red

240 Volts

Black & Orange

Each CP series relay panel comes pre-wired to the 

included transformer, terminal blocks, and the coil 

terminals on the provided contactors. It is not 

recommended to unwire, or tamper with existing 

wiring without pre-authorization from the factory.

!

 

WARNING: General Safety Instructions

1.

  

THIS UNIT SHOULD BE INSTALLED ONLY BY  

QUALIFIED PERSONNEL!

2.  Disconnect all power from the control before 

opening the front cover plate.

CP-50, CP-100, CP-200 Specifications

Terminals

Wiring Type

L1, L2
T1, T2

120, 208, 240, 277 VAC

12 AWG 

(Minimum)

PM

Class 2, 

18-24 AWG 

(See sensor 
instructions 
for size and 

length limits)

24VAC, COMMON

24 VAC

X1, X2

Dry Contact, N.O.

Compatible Sensors

PM-224
PM-824

PM-HSC5

ETL Listing

 File 3176880, 

UL 508A, 

CAN/CSA-C22.2 No. 14

Environment

Indoor, NEMA 1 

enclosure, operating 

temperature 0ºF to 100ºF 

(-18ºC to 38ºC)

Limited Warranty:

 Watts Radiant (the “Company”) warrants each product to be free from defects in material and workmanship under normal usage for a period of one year from the date of original shipment.  In 

the event of such defects within the warranty period, the Company will, at its option, replace or recondition the product without charge.  

THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN BY THE COMPANY WITH RESPECT TO THE PRODUCT.  THE COMPANY MAKES NO OTHER WARRANTIES, 

EXPRESS OR IMPLIED.  THE COMPANY HEREBY SPECIFICALLY DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF 

MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.

The remedy described in the first paragraph of this warranty shall constitute the sole and exclusive remedy for breach of warranty, and the Company shall not be responsible for any incidental, special or consequen-

tial damages, including without limitation, lost profits or the cost of repairing or replacing other property which is damaged if this product does not work properly, other costs resulting from labor charges, delays, 

vandalism, negligence, fouling caused by foreign material, damage from adverse water conditions, chemical, or any other circumstances over which the Company has no control.  This warranty shall be invalidated 

by any abuse, misuse, misapplication, improper installation or improper maintenance or alteration of the product.  

Some States do not allow limitations on how long an implied warranty lasts, and some States do not allow the exclusion or limitation of incidental or consequential damages.  Therefore the above limitations may not 

apply to you.  This Limited Warranty gives you specific legal rights, and you may have other rights that vary from State to State.  You should consult applicable state laws to determine your rights.  

SO FAR AS IS 

CONSISTENT WITH APPLICABLE STATE LAW, ANY IMPLIED WARRANTIES THAT MAY NOT BE DISCLAIMED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR 

PURPOSE, ARE LIMITED IN DURATION TO ONE YEAR FROM THE DATE OF ORIGINAL SHIPMENT.

IS-WR-PM-Contactor-Pro-Panels  1233 

© 2012 Watts Radiant

USA:

  4500 East Progress Place, Springfield, MO 65803; www.wattsradiant.com

Canada:

  5435 North Service Rd., Burlington, ONT. L7L 5H7; www.watts.ca 

A Watts Water Technologies Company

EDP# 81012456