![background image](http://html1.mh-extra.com/html/watts/oneflow-oftwh/oneflow-oftwh_installation-operation-and-maintenance-manual_3763158004.webp)
4
Max Pressure: 90psi
Max Temperature: 100ºF
Wall
2'- 8" Min.
— 5'- 0" A.F
.F.
Installation Height
1'- 9 7/8"
3 1/2"
5 1/8"
2 7/8"
to inlet
3" Min.
Remo
val
Clearance
Water filtration unit
must be installed on the
cold water supply only
Mounted to
secure wall
on studs or
wall panel –
Do not mount
to unsupported
sheet-rock
or gypsum board.
3/4" Full flow
ball valve inlet
connection to
water supply
Installation Drawings & Dimensions
3/4" MPT
adapter
req'd to
adapt to
FPT outlet
Max Pressure: 90psi
Max Temperature: 100ºF
3/4" MPT
adapter
req'd to
adapt to
FPT inlet
3/4" pipe or
3/4" I.D. flexible
reinforced
beverage tubing
from chlorinated
municipal water
supply
Water
Supply
Floor Line
Install – Min.–
3/4" full flow
ball valve
w/ 3/4" FPT
inlet connection
(Valve not incl'd)
2'- 8" Min.
— 5'- 0" A.F
.F.
Installation Height
3" Min.
Remo
val
Clearance
Water filtration unit
must be installed on the
cold water supply only
NOTE:
Do not mount filter
assembly behind ice
machine or other
appliances that would
impede access for
maintenance of
filtration system
Provide appropriate
pipe/tubing for
filtered and
treated water
to equipment