Installation, Operation and 
Maintenance Manual

Model OFTWH

OneFlow

®

 Anti-Scale System 

Chemical-Free, Salt-Free Scale Prevention

Introduction

The OneFlow

®

 Anti-Scale System will condition the tap water 

providing optimum water characteristics for their specified appli-

cations. The result is reduced equipment maintenance require-

ments, longer equipment life and improved quality & consistency 

of your products. 
The OneFlow

®

 system is built with the finest and most advanced 

materials and each system is quality inspected and pressure 

tested prior to shipment. With proper installation and routine 

maintenance, you will have years of trouble-free operation. 
Please refer to this manual when performing routine filter chang-

es. The instructions make periodic maintenance quick and easy 

and ensure you will receive maximum benefit from your system.

System Specifications

Inlet/Outlet Connections:

 

3

/

4

" FNPT 

Nominal Flow Rate up to 10 gpm (39 lpm)

 

Gallon Rating:

 OFTWH: up to 6 gpm, 24/7/365 for 2 years 

for the OFTWHRM.

Capacity:

 OFTWHRM cartridge does not have a grain removal 

capacity, however, other contaminants present in the water will 

gradually degrade the effectiveness of this cartridge. Change the 

OFTWHRM cartridge at least once every two years.

IOM-OFTWH

WARNING

!

Read this Manual BEFORE using this equipment.
Failure to read and follow all safety and use information 

can result in death, serious personal injury, property 

damage, or damage to the equipment.
Keep this Manual for future reference.

WARNING

!

Need for Periodic Inspection and Yearly Maintenance:  

 

Periodic inspection and yearly maintenance by a licensed 

contractor is required. Corrosive water conditions and/or 

unauthorized adjustments or repair could render the valve 

ineffective for service intended. Regular checking and 

cleaning of the valve’s internal components and check 

stops helps assure maximum life and proper product 

function. Frequency of cleaning and inspection depends 

upon local water conditions.

You are required to consult the local building and plumbing 

codes prior to installation.  If the information in this manual is 

not consistent with local building or plumbing codes, the local 

codes should be followed. Inquire with governing authorities 

for additional local requirements.

WARNING

!

Summary of Contents for OneFlow OFTWH

Page 1: ...ge does not have a grain removal capacity however other contaminants present in the water will gradually degrade the effectiveness of this cartridge Change the OFTWHRM cartridge at least once every tw...

Page 2: ...r gallon 513 ppm CaCO3 of calcium carbonate Due to variances in water chemistry 30 grains per gallon is a recommended hard ness maximum due to potential aesthetic issues related to soft scale residue...

Page 3: ...e tubing to the equipment at this time Prior to making connection to the equipment this line will be used to facilitate flushing the system As an option a drain valve in a tee on the outlet side of th...

Page 4: ...FPT outlet Max Pressure 90psi Max Temperature 100 F 3 4 MPT adapter req d to adapt to FPT inlet 3 4 pipe or 3 4 I D flexible reinforced beverage tubing from chlorinated municipal water supply Water S...

Page 5: ...g if equipped and flush the new cartridge to drain or bucket for two 2 minutes or until water runs clear If no flush valve is present disconnect line from equipment to flush to drain 10 With water sup...

Page 6: ...ts for OneFlow OFTWH Drawing ID Description 1 Housing w PR 1a O Ring 2 Valve 3 4 FxM Ball 3 Bracket Single Housing 4 Screw 5 OFTWHRM Replacement Cartridge 6 Pressure Relief Button IN OUT inlet outlet...

Page 7: ......

Page 8: ...e Such replacement parts will be delivered to the owner F O B nearest factory at no cost excluding freight and local labor charges if any Our obligation under this warranty with respect to the OneFlow...

Page 9: ...ouche OFTWHRM ne permet pas d liminer les grains cependant d autres contaminants pr sents dans l eau d graderont graduellement l efficacit de cette cartouche Remplacez la cartouche OFTWHRM au moins un...

Page 10: ...rbonate de calcium En raison des variations de la chimie de l eau 30 grains par gallon sont un maximum de duret recommand e en raison de probl mes esth tiques potentiels li s la formation de r sidus f...

Page 11: ...quipement ce stade Avant de faire le raccordement l quipement cette conduite sera utilis e pour faciliter la vidange du syst me Ou un robinet de vidange dans un T sur le c t sortie du syst me OneFlow...

Page 12: ...ture maximale 100 F 38 C Adaptateur MPT 3 4 po 19 mm n cessaire pour s adapter l entr e FPT Tuyau de 3 4 po 19 mm ou tuyau distributeur de boisson flexible renforc de 3 4 po 19 mm de diam tre int rieu...

Page 13: ...i quip et rincez la nouvelle cartouche dans le drain ou le seau pendant deux 2 minutes ou jusqu ce que l eau soit claire S il n y a pas de robinet de rin age d tacher la conduite de l quipement pour v...

Page 14: ...du dessin Description 1 Porte filtre avec PR 1a Joint torique 2 Robinet bille FxM de 3 4 po 19 mm 3 Support porte filtre simple 4 Vis 5 Cartouche de remplacement OFTWHRM 6 Bouton de d charge de la pr...

Page 15: ...15...

Page 16: ...e r v lent d fectueuse s pendant la p riode de garantie indiqu e ci dessus Ces pi ces de rechange seront livr es au propri taire F O B franco bord l usine la plus proche sans frais l exclusion des fra...

Page 17: ...de eliminaci n de dureza granos sin embargo otros contaminantes presentes en el agua degradar n gradualmente la efectividad de este cartucho Cambie el cartucho OFTWHRM al menos una vez cada dos a os...

Page 18: ...to c lcico Debido a las variaciones en la qu mica del agua 30 granos por gal n es el m ximo de dureza recomendado debido a posibles problemas est ticos relacionados con la formaci n de residuos de sar...

Page 19: ...ecte la tuber a al equipo en este momento Antes de conectar al equipo esta l nea se utilizar para facilitar el lavado del sistema Como opci n se puede proporcionar una v lvula de drenaje en una T situ...

Page 20: ...arse a la salida FPT Presi n m xima 90 psi Temperatura m xima 100 F 38 C Adaptador MPT de 3 4 necesario para adaptarse a la entrada de FPT Tubo de 3 4 o tubo de bebidas reforzado con D I de 3 4 de sum...

Page 21: ...te de la v lvula de lavado de la carcasa del filtro si la hay y lave el cartucho nuevo al drenaje o la cubeta durante dos 2 minutos o hasta que el agua salga limpia Si no hay v lvula de lavado descone...

Page 22: ...w OFTWH N de id de dibujo Descripci n 1 Carcasa con PR 1a Junta t rica 2 V lvula 3 4 FXm Bola 3 Soporte carcasa nica 4 Tornillo 5 Cartucho de remplazo OFTWHRM 6 Bot n de alivio de presi n IN OUT inlet...

Page 23: ......

Page 24: ...te Dichos remplazos se entregar n a la f brica LAB libre a bordo m s cercana al propietario sin costo alguno sin incluir los cargos de flete y mano de obra local si los hubiera Nuestra obligaci n en v...

Reviews: