Equipment  

Specifications

OneFlow

®

 systems are complete, self-

contained, loaded with media, and ready to 

use. A simple inlet and outlet connection is all 

that is required for installation. Please review 

operating pressures, temperatures and water 

chemistry limitations to ensure compatibility.

Replacement Media

Weights and Dimensions (nominal - inches)

MODEL

OF1260-30TM

OF1465-50TM

OF1665-75TM

Dry Weight

72 lbs.

33 kgs.

98 lbs.

44 kgs. 120 lbs. 54 kgs.

Service Weight

394 lbs. 179 kgs. 442 lbs. 201 kgs. 521 lbs. 236 kgs.

Dimensions

A - 12

B - 63.7

A - 14

B - 68.8

A - 16

B - 68.8

MODEL

REPLACEMENT FREQUENCY

OF1260RM

Media should be replaced every 3 years

OF1465RM

Media should be replaced every 3 years

OF1665RM

Media should be replaced every 3 years

Connections

MODEL

INLET/OUTLET CONNECTION

OF1260-30TM

2" PVC FNPT

OF1465-50TM*

2" PVC FNPT

OF1665-75TM*

2" PVC FNPT

B

A

Maximum Flow Rate ***

MODELS

GPM

LPM

OF1260-30TM

30

114

OF1465-50TM

50

189

OF1665-75TM

75

284

*** Exceeding maximum flow can reduce effectiveness and void warranty.
Pressure drop at peak flow rate is less than 22psi.
Pressure drop reading taken with inlet and outlet gauges installed at a  

common elevation and 80ºF feed water.

Intermittent Duty Systems

MODEL

FLOW RATE

OF1260-30TM

30 GPM at all temperatures

OF1465-50TM

50 GPM at all temperatures

OF1665-75TM

75 GPM at all temperatures

Intermittent duty is defined as less than 2 hours of Maximum 

Flow per 24 hour period. Higher Flow rates can be achieved by 

combining systems in an array.

Maximum Service Flow (gpm) vs.  

Water Temperature 

SYSTEM

40°F

45°F

50°F

55°F

60°F

65°F

70°F

OF1260-30TM

20

24

28

30

30

30

30

OF1465-50TM

40

44

48

50

50

50

50

OF1665-75TM

45

51

56

59

63

69

75

NOTICE

*For models OF1465-50TM and OF1665-75TM, Two 2" MNPT Flex 

Connectors are included and required for each tank installation

NOTICE

  *  Systems using OneFlow

®

 technology are effective at 

controlling lime-scale formation inside the plumbing system at 

influent hardness levels up to 75 grains per gallon (1282 mg/L) 

of calcium carbonate. Due to variances in water chemistry, 

30 grains per gallon is a recommended hardness maximum 

due to potential aesthetic issues related to soft scale residue 

formation outside of the plumbing system. Testing should be 

performed to determine proper application where hardness 

levels exceed 30 grains per gallon.

  ** Just as with conventional water softening media, OneFlow

®

 

media needs to be protected from excess levels of certain 

metals that can easily coat the active surface, reducing its 

effectiveness over time. Public water supplies rarely, if ever, 

present a problem, but if the water supply is from a private 

well, confirm that the levels of iron (Fe) and manganese (Mn) 

are less than 0.3 mg/L and 0.05 mg/L, respectively.

*** Pursuant to the EPA drinking water standards, the copper 

concentration permitted is up to 1.3 ppm. Typically 

originating from new copper plumbing, high levels of 

copper can foul OneFlow media. New Copper lines need 

to be passivated for a minimum of 4 weeks before placing 

unit into service. For applications with copper concentration 

greater than 1.3 ppm, please consult Watts Water Quality 

Technical Service. To further minimize any problem with 

excess copper, avoid applying excessive flux on the inner 

surfaces of the pipe and use a low-corrosivity water soluble 

flux listed under the ASTM B813 standard.

 

 

WARNING

!

Feed Water Chemistry Requirements

pH

6.5-8.5

Hardness (maximum)

30 grains (513 ppm CaCO3) *

Water Pressure

15psi to 100psi (1.03 bar to 6.9 bar)

Temperature

40°F to 100°F (5°C to 38°C)

Free Chlorine

<2 ppm

Iron (maximum)

0.3 ppm **

Manganese (maximum)

0.05 ppm **

Copper (maximum)

1.3 ppm***

Oil & H2S

Must be Removed Prior to OneFlow

Total Phosphates

<3.0 ppm

Silica (maximum)

20 ppm †

TDS

<1500 mg/L ††

NOTICE

† OneFlow

®

 media does not reduce silica scaling. While silica 

tends to have a less significant effect on scale formation than 

other minerals, it can act as a binder that makes water spots 

and scale residue outside the plumbing system difficult to 

remove. This 20 ppm limitation is for aesthetic purposes.
†† All other contaminants must meet the requirements of the 

USEPA Safe Drinking Water Act. Specific Mineral and Metal 

MCL's, identified in Watts published Feed Water Chemistry 

Requirements, supersedes the USEPA SDWA.
Water known to have heavy loads of dirt and debris may require 

pre-filtration prior to OneFlow

®

.

Summary of Contents for OneFlow OF1260-30TM

Page 1: ...of all water using appliances both hot and cold Simple sizing installation all you need to know is pipe size and the peak flow rate Safe for landscaping and lawn watering no need for costly bypass pl...

Page 2: ...ndry and ware washing chemistry will likewise require adjustments WARNING Specifications A OneFlow scale prevention system shall be installed on the main water service pipe just after it enters the bu...

Page 3: ...is a recommended hardness maximum due to potential aesthetic issues related to soft scale residue formation outside of the plumbing system Testing should be performed to determine proper application w...

Page 4: ...ggested Watts 2 Flexible Connec tors is C515285 Two are included and required for installation Models OF1260 30TM OF1465 50TM and OF1665 75TM Anytime OneFlow systems are installed above the ground flo...

Page 5: ...rden hose and continue to siphon until the tank is about half full with water 12 Using the step ladder again reinstall the distributer tube with bottom strainer that was removed in step 6 Center the d...

Page 6: ...ASSEMBLY 2 1 C515285 FLEX HOSE 2 X 12 OF1465 OF1665 MODELS ONLY 3 1 7300784 DISTRIBUTOR TUBE BOTTOM DISTRIBUTOR ASSEMBLY 4a 1 7300899 12 x 60 TANK 4 TOP OF1260 MODEL ONLY 4b 1 68100998 14 X 65 TANK 4...

Page 7: ...he tank or valve is limited to furnishing a replacement for or at our option repairing any part or parts to our satisfaction that prove defective within the warranty period stated above Such replaceme...

Page 8: ...IOM OF1260TM_OF1465TM_OF1665TM 2228 EDP 2915219 2022 Watts USA T 800 224 1299 Watts com Canada T 905 332 4090 Watts ca Latin America T 52 55 4122 0138 Watts com...

Page 9: ...ora la eficiencia de todos los aparatos que utilizan agua fr a o caliente Tama o e instalaci n simples lo nico que necesita saber es el tama o de las tuber as y el caudal de flujo m ximo Es seguro par...

Page 10: ...El sistema de prevenci n de sarro OneFlow debe instalarse en la tuber a de servicio de agua principal justo despu s de que ingresa en el edificio pero despu s de otros dispositivos de seguridad del a...

Page 11: ...os por fuera del sistema de plomer a Se deben realizar pruebas para determinar la aplicaci n adecuada en la que los niveles de dureza exceden los 30 granos por gal n Al igual que con los medios suaviz...

Page 12: ...as con el soporte apropiado Instale las tuber as Conecte las tuber as de entrada y salida seg n sus preferencias y cualquier reglamento local aplicable Incluya puertos de muestreo drenaje con conexio...

Page 13: ...sta que el tanque est lleno hasta la mitad de agua 12 Utilizando nuevamente la escalera reinstale el tubo de distribuci n con tamiz inferior que se quit en el paso n 6 Centre el tubo distribuidor en l...

Page 14: ...OF1465 Y OF1665 3 1 7300784 CONJUNTO DE TUBO DISTRIBUIDOR Y DISTRIBUIDOR INFERIOR 4a 1 7300899 TANQUE DE 12 IN X 60 IN 30 5 CM X 152 4 CM PARTE SUPERIOR DE 4 10 CM SOLO MODELO OF1260 4b 1 68100998 TA...

Page 15: ...nt a con respecto al tanque o la v lvula est limitada al reemplazo o la reparaci n a nuestra elecci n de cualquier pieza o piezas a nuestra satisfacci n con defectos comprobados dentro del per odo de...

Page 16: ...IOM OF1260TM_OF1465TM_OF1665TM 2228 EDP N 2915219 2022 Watts EE UU T 800 224 1299 Watts com Canad T 905 332 4090 Watts ca Am rica Latina T 52 55 4122 0138 Watts com...

Page 17: ...u us e Am liore l efficacit de tous les appareils utilisant de l eau eau chaude et eau froide Dimensionnement et installation simples tout ce que vous devez savoir est la taille du tuyau et le d bit d...

Page 18: ...vage de vaisselle n cessiteront galement des ajustements AVERTISSEMENT Caract ristiques techniques Un syst me de pr vention du tartre OneFlow sur le principal tuyau de branchement d eau juste apr s l...

Page 19: ...de probl mes esth tiques potentiels li s la formation de r sidus faible chelle l ext rieur du syst me de plomberie Des essais doivent tre effectu s afin de d terminer l application appropri e lorsque...

Page 20: ...recommand est C515285 deux sont inclus et requis pour l installation Mod les OF1260 30TM OF1465 50TM et OF1665 75TM Lorsque les syst mes OneFlow sont install s au rez de chauss e d un b timent il est...

Page 21: ...e tuyau d arrosage et continuez siphonner jusqu ce que le r servoir soit moiti plein d eau 12 En utilisant nouveau l chelle r installez le tube de distributeur avec filtre en bas qui a t retir l tape...

Page 22: ...1 7300784 TUBE DE DISTRIBUTEUR ET ASSEMBLAGE DE DISTRIBUTEUR INF RIEUR 4a 1 7300899 PARTIE SUP RIEURE 4 po 101 6 mm R SERVOIR 12 X 60 po 304 8 X 1524 mm MOD LE OF1260 SEULEMENT 4b 1 68100998 PARTIE S...

Page 23: ...Limitations Notre obligation en vertu de la pr sente garantie par rapport au r servoir ou la vanne est limit e fournir un remplacement pour ou selon notre option la r paration de l ensemble des pi ces...

Page 24: ...IOM OF1260TM_OF1465TM_OF1665TM 2228 EDP 2915219 2022 Watts U T l phone 800 224 1299 Watts com Canada T l phone 905 332 4090 Watts ca Am rique latine T l phone 52 55 4122 0138 Watts com...

Reviews: