background image

5

Replacing the Media 

1.    Shut off the primary water supply going to the OneFlow

®

 tank.

2.    Open up a downstream spigot or faucet to release pressure 

in the tank and in the distribution lines before and after  

the system.

3.    Close the inlet and outlet isolation valves immediately before 

and after the tank and open the bypass valve.

4.    Disconnect the unions on the inlet and outlet of the tank, 

and then disconnect flex connectors from head.

5.    Using a step ladder and strap wrench, remove the threaded 

head assembly connection (turning counter-clockwise) and 

remove the complete upper assembly including the screen 

attached to the bottom of the head assembly. Rinse these 

parts in a nearby sink or bucket of water. Do not drain  

the tank.

6.    Remove the distributor tube with the bottom strainer. Rinse 

these parts in a nearby sink or bucket of water. 

7.    Get a 6ft length of 3/4" sch. 40 PVC and a length of 1" polyvinyl 

hose. The length of hose depends on the distance to the 

nearest floor drain. (Both of these can be acquired at a local 

hardware store.) 

8.    Insert one end of the pipe inside the hose and put the other 

end of the pipe into the top of the tank and down into the 

media. Put the other end of the hose inside a rice bag and 

put the rice bag on the floor drain.

9.    Get a garden hose and put it on the open end of the polyvinyl 

hose to fill the hose and pipe with water. Air will bubble out 

of the tank. Once all the air is out of the hose and pipe, you 

can start a siphon to remove the media. Put the garden 

hose in the top of the tank and turn it on to keep the tank 

full of water. Push the pipe up and down in the media to get 

it all out. The rice bag will catch the media and allow the 

water to go down the drain.

10.  Try not to be too aggressive when extracting the media.  

You need to take it out in small bites. If you let the whole 

pipe/hose fill with media it will plug up. You need to let slugs 

of water flush out the pipe as you go.

11.  When all the old media is removed turn off the garden  

hose and continue to siphon until the tank is about half full 

with water.

12.  Using the step ladder again, reinstall the distributer tube with 

bottom strainer that was removed in step #6. Center the 

distributor tube in the bottom of the tank. Make sure the  

distributor tube is flush with the top of the tank and cap 

the top open end of the distributor tube with tape and 

plastic sheeting. Keeping any and all media from entering 

the distributor tube, carefully pour-in a new bag(s) of media 

that specifically meets the replacement requirement of the 

tank. For example, an OF1665-75TM system requires (x1) 

OF1665RM Replacement Media.

13.  Inspect the threaded connection on the top of the tank to 

ensure no loose beads of media are stuck to the internal 

threads. If visible, wipe away the beads with a damp cloth, 

then remove the plastic sheeting and tape from the top of 

the distributor tube. 

14.  Re-attach the head assembly onto the distributor tube and 

thread the head assembly back onto the tank. Hand-tighten 

until the final turn when a strap wrench can help tighten  

the connection.

Your OneFlow

®

 media should be replaced every 3 years. Dispose 

of old media and/or container in accordance with local, regional, 

national, and/or international regulations.

NOTICE

Follow steps 1 – 6 then,

 •  Remove center distributor tube and lower basket and siphon 

all water from tank

 •  Lay tank down on its side and tip upside down while using 

hose to flush media out

 •  When all the old media is removed, stand tank back up and 

install in original position. Fill the tank so that it is about half 

full with water.

Then continue with steps 12 – 19.

Alternative Method for  

Replacing Media

3/4"  

PVC PIPE

1" HOSE

FLOOR DRAIN

BAG

15. Reconnect the flex connectors and union connections.
16.  Fully open the primary water supply valve and close the 

bypass valve.

17.  Slowly open the outlet isolation valve and slightly open the 

inlet isolation valve to allow water to flow into the system 

and out of a downstream cold side faucet to purge the air 

from the tank and plumbing system.

18. Once the tank is full, wait 4 hours for media to “hydrate”.
19.  Slowly, fully open the inlet isolation valve. The system is now 

ready for operation. 

Summary of Contents for OneFlow OF1260-30TM

Page 1: ...of all water using appliances both hot and cold Simple sizing installation all you need to know is pipe size and the peak flow rate Safe for landscaping and lawn watering no need for costly bypass pl...

Page 2: ...ndry and ware washing chemistry will likewise require adjustments WARNING Specifications A OneFlow scale prevention system shall be installed on the main water service pipe just after it enters the bu...

Page 3: ...is a recommended hardness maximum due to potential aesthetic issues related to soft scale residue formation outside of the plumbing system Testing should be performed to determine proper application w...

Page 4: ...ggested Watts 2 Flexible Connec tors is C515285 Two are included and required for installation Models OF1260 30TM OF1465 50TM and OF1665 75TM Anytime OneFlow systems are installed above the ground flo...

Page 5: ...rden hose and continue to siphon until the tank is about half full with water 12 Using the step ladder again reinstall the distributer tube with bottom strainer that was removed in step 6 Center the d...

Page 6: ...ASSEMBLY 2 1 C515285 FLEX HOSE 2 X 12 OF1465 OF1665 MODELS ONLY 3 1 7300784 DISTRIBUTOR TUBE BOTTOM DISTRIBUTOR ASSEMBLY 4a 1 7300899 12 x 60 TANK 4 TOP OF1260 MODEL ONLY 4b 1 68100998 14 X 65 TANK 4...

Page 7: ...he tank or valve is limited to furnishing a replacement for or at our option repairing any part or parts to our satisfaction that prove defective within the warranty period stated above Such replaceme...

Page 8: ...IOM OF1260TM_OF1465TM_OF1665TM 2228 EDP 2915219 2022 Watts USA T 800 224 1299 Watts com Canada T 905 332 4090 Watts ca Latin America T 52 55 4122 0138 Watts com...

Page 9: ...ora la eficiencia de todos los aparatos que utilizan agua fr a o caliente Tama o e instalaci n simples lo nico que necesita saber es el tama o de las tuber as y el caudal de flujo m ximo Es seguro par...

Page 10: ...El sistema de prevenci n de sarro OneFlow debe instalarse en la tuber a de servicio de agua principal justo despu s de que ingresa en el edificio pero despu s de otros dispositivos de seguridad del a...

Page 11: ...os por fuera del sistema de plomer a Se deben realizar pruebas para determinar la aplicaci n adecuada en la que los niveles de dureza exceden los 30 granos por gal n Al igual que con los medios suaviz...

Page 12: ...as con el soporte apropiado Instale las tuber as Conecte las tuber as de entrada y salida seg n sus preferencias y cualquier reglamento local aplicable Incluya puertos de muestreo drenaje con conexio...

Page 13: ...sta que el tanque est lleno hasta la mitad de agua 12 Utilizando nuevamente la escalera reinstale el tubo de distribuci n con tamiz inferior que se quit en el paso n 6 Centre el tubo distribuidor en l...

Page 14: ...OF1465 Y OF1665 3 1 7300784 CONJUNTO DE TUBO DISTRIBUIDOR Y DISTRIBUIDOR INFERIOR 4a 1 7300899 TANQUE DE 12 IN X 60 IN 30 5 CM X 152 4 CM PARTE SUPERIOR DE 4 10 CM SOLO MODELO OF1260 4b 1 68100998 TA...

Page 15: ...nt a con respecto al tanque o la v lvula est limitada al reemplazo o la reparaci n a nuestra elecci n de cualquier pieza o piezas a nuestra satisfacci n con defectos comprobados dentro del per odo de...

Page 16: ...IOM OF1260TM_OF1465TM_OF1665TM 2228 EDP N 2915219 2022 Watts EE UU T 800 224 1299 Watts com Canad T 905 332 4090 Watts ca Am rica Latina T 52 55 4122 0138 Watts com...

Page 17: ...u us e Am liore l efficacit de tous les appareils utilisant de l eau eau chaude et eau froide Dimensionnement et installation simples tout ce que vous devez savoir est la taille du tuyau et le d bit d...

Page 18: ...vage de vaisselle n cessiteront galement des ajustements AVERTISSEMENT Caract ristiques techniques Un syst me de pr vention du tartre OneFlow sur le principal tuyau de branchement d eau juste apr s l...

Page 19: ...de probl mes esth tiques potentiels li s la formation de r sidus faible chelle l ext rieur du syst me de plomberie Des essais doivent tre effectu s afin de d terminer l application appropri e lorsque...

Page 20: ...recommand est C515285 deux sont inclus et requis pour l installation Mod les OF1260 30TM OF1465 50TM et OF1665 75TM Lorsque les syst mes OneFlow sont install s au rez de chauss e d un b timent il est...

Page 21: ...e tuyau d arrosage et continuez siphonner jusqu ce que le r servoir soit moiti plein d eau 12 En utilisant nouveau l chelle r installez le tube de distributeur avec filtre en bas qui a t retir l tape...

Page 22: ...1 7300784 TUBE DE DISTRIBUTEUR ET ASSEMBLAGE DE DISTRIBUTEUR INF RIEUR 4a 1 7300899 PARTIE SUP RIEURE 4 po 101 6 mm R SERVOIR 12 X 60 po 304 8 X 1524 mm MOD LE OF1260 SEULEMENT 4b 1 68100998 PARTIE S...

Page 23: ...Limitations Notre obligation en vertu de la pr sente garantie par rapport au r servoir ou la vanne est limit e fournir un remplacement pour ou selon notre option la r paration de l ensemble des pi ces...

Page 24: ...IOM OF1260TM_OF1465TM_OF1665TM 2228 EDP 2915219 2022 Watts U T l phone 800 224 1299 Watts com Canada T l phone 905 332 4090 Watts ca Am rique latine T l phone 52 55 4122 0138 Watts com...