10  Maintenance

DANGER

Electrical energy!

Perform maintenance work on the ISOTHERM only when 
the power supply has been disconnected.

!

!

 

WARNING

Hot water!

Risk of severe scalding.
Do not reach into the hot water when emptying the 
ISOTHERM. Ensure that the ISOTHERM has cooled 
down before carrying out maintenance, cleaning and 
repair work.

!

!

 

WARNING

Hot surfaces!

Risk of serious burns.
Do not touch the pipes or components during operation. 
Ensure that the ISOTHERM has cooled down before car-
rying out maintenance, cleaning and repair work. Wear 
heat-resistant safety gloves if it is necessary to carry out 
work on hot components.

NOTICE

Maintenance of the ISOTHERM must be

carried out only by trained personnel who have been 
authorized by the manufacturer.

10.1  Annual maintenance

1. General visual inspection

•   Check the control station for leaks and retighten sealing 

connections or replace seals, as required.

2. Functional check

•   Check that settings and operating and performance 

parameters are set correctly.

•   Check supply noise during operation.
•   Ask users if there are any noticeable problems.

3. Action to be taken following maintenance work

•   Check that all screw fittings that were unscrewed have 

been retightened and retighten if necessary.

•   Remove all tools, materials and other equipment used from 

the working area.

•  Restore the power supply.
•   Slowly pressurize the ISOTHERM and vent it. 
•   Readjust the system settings if required.

10.2   Replacement of wear parts

Please note that the ISOTHERM contains parts that, for tech-
nical reasons, are subject to wear depending on the intensity 
of use, even if the specified care and maintenance has been 
provided. 
This applies especially to mechanical parts and parts that 
come into contact with water and steam, such as seals, 
valves, etc. 
By their nature, defects caused by wear do not constitute a 
fault and are therefore not covered by the warranty or any 
guarantee. Nevertheless, these defects and malfunctions 
must be remedied by trained specialist personnel only. 
Contact your specialist dealer for this.

Summary of Contents for Isotherm

Page 1: ...Isotherm Control station for constant maintenance of the supply temperature in surface heating systems Installation and Operating Manual translated from the original operating manual WattsWater eu ...

Page 2: ...l information 1 1 Important information about this manual NOTICE The plant operator is responsible for ensuring compliance with the local laws and regula tions e g accident prevention regulations etc Incorrect operation or operating the ISOTHERM out side the specifications invalidates all warranty claims This installation and operating manual is an integral part of the ISOTHERM contains instructio...

Page 3: ...be operated by people including children with limited physical sensory or mental capacities or by people with insufficient experience or previ ous knowledge 2 4 Foreseeable misuse The following is considered to be foreseeable misuse Operating the ISOTHERM beyond its specifications Improper use of the ISOTHERM Modifications to the ISOTHERM that have not been agreed with the manufacturer Use of repl...

Page 4: ...a the circulation pump 1 to the supply of the surface heating heating circuit manifold C and from there to the connected heating circuits as well as being routed as a pilot flow via the bypass 4 In the event of malfunction the temperature limiter 5 switch es off the circulation pump to prevent overheating of the sur face heating system 5 Technical Data Hydraulic performance data Max operating pres...

Page 5: ...12 287 ca 98 G1 G1 37 216 116 1 Fl 1 Fl 75 Fig 6 1 Overall dimensions 7 Pressure loss diagram 1 10 100 1 000 10 100 1 000 10 000 KVS 4 5 KV2 1 2 KV1 0 6 KV1 Bypass KV2 Einspritzung Injection KVS Verteilerseitig Manifold side Fig 7 1 Pressure loss diagram Flow rate l h Pressure loss mbar ...

Page 6: ...ng on space limitations and dimensions of the heat ing circuit manifold it may be necessary to rotate the pump in the axis of the screw connections To do this loosen the two union nuts on the pump rotate the pump into the required position and then tighten the screw connections while holding both the pump and the screw connection ele ment in place WW Fig 8 1 NOTICE We recommend installing a strain...

Page 7: ...ting circuit Factory setting of the target supply temperature is 44 C or 55 C depending on the version of the control station The pilot pin is flush with the setting hand wheel face By turning the setting hand wheel in minus or plus direction the target supply temperature is changed accordingly The hand wheel clicks with the rotation Each click means a target temperature change of approx 1 C Fig 8...

Page 8: ...anifold Subsection 1 1 should also be taken into consideration 1 4 The difference between the temperature of the boiler s sup ply water and the required supply temperature of the sur face heating is too small for the existing heating load Set the boiler s supply water temperature to a higher value At maximum power consumption in the heating circuits of the surface heating the Heating boiler s supp...

Page 9: ... seals as required 2 Functional check Check that settings and operating and performance parameters are set correctly Check supply noise during operation Ask users if there are any noticeable problems 3 Action to be taken following maintenance work Check that all screw fittings that were unscrewed have been retightened and retighten if necessary Remove all tools materials and other equipment used f...

Page 10: ... and components are de energized 2 Disassemble the ISOTHERM properly or commission a specialist company to do so 3 Sort the assemblies and component parts into recyclable materials hazardous substances and operating materials 4 Dispose of the assemblies and components in accord ance with local laws and regulations or take them to be recycled 11 1Return to the manufacturer Get in contact with the m...

Reviews: