4
Installation:
1.
The unit should be installed indoors. Make sure there is at least four feet of clear space
available above the unit. The space above the unit is necessary for cartridge and UV
lamp replacement.
2.
Remove the union adapters from the package and put the union ring over the adapter.
Apply Teflon tape to the gauge threads and screw the gauges into the adapters (see figure
1).
3.
Turn off the water supply.
4.
Plumb the unit to the water supply line (see figure 1). It is recommended that ball valves
(not included with unit) be installed in the inlet and outlet piping for more convenient
filter cartridge and UV lamp replacement.
5.
Remove the lid by loosening the swing bolts and verify that the filter cartridge and
stainless steel UV chamber are installed (see figure 2).
6.
Replace the lid and tighten the swing bolts in a crisscross pattern.
7.
Remove the retaining nut and carefully install the quartz sleeve and o-ring (see figure 3).
Do not touch the sides of the quartz or the lamp. The retaining nut only needs to be
finger tight. Note: Over tightening the retaining nut will cause the quartz sleeve to break.
8.
Orient the UV lamp with the four-pin connector pointing up and gently lower the lamp
into the quartz sleeve (see figure 4). Do not drop the lamp into the sleeve (the sleeve
and/or lamp could break).
9.
Make sure the power supply is not plugged in.
Connect the plug from the power
supply to the four-pin connector on the lamp. Cover the end of the lamp with the vinyl
cap (see figure 5)
10.
Attach the power supply to the side of the filter housing with the included Velcro.
Figure 3
Figure 4
Figure 5
Figure 2
Figure 1