Installation Instructions
Water supply Requirements
•
Cold water inlet only, working water temperature 1-40 °C. Protect from freezing at all times.
•
Supply pressure
≤
500kPa. An approved pressure limiting valve must be installed by a licensed
person in situations where supply pressure could exceed 500kPa.
•
Contamination could be present in the water system before the product is installed. Flush the
water system after installation and consult an expert if water treatment is required at the
source.
Environment Requirements
•
The Hydroguard can be installed indoors or outdoors, but should be protected from harsh
chemical or salt air environments to prevent premature corrosion.
•
The mounting fixture must be solid and capable of supporting the weight of the product when
filled with water.
•
Minimise exposure of the filter housings to direct sunlight and protect the system from
freezing at all times. Ambient temperature 1-40 °C.
Product and Position Preparation
Remove all packaging and dispose of it responsibly. Check all components are present and
undamaged.
Select a suitable location to install:
•
The wall fitting needs to be sufficiently strong to support the weight of the product when filled
with water.
•
Avoid locations where the unit is in direct sunlight or at risk of freezing.
•
Check the location has suitable access to the supply and building plumbing, and be within x m
of a suitable power outlet. A licensed plumber or electrician may be required if appropriate
fixtures are not available.
•
At least 80 mm of clearance below the filter housings is required for the replacement of filter
cartridges. Refer to diagram below.