4
IM-HKM40-50_HK40-50-DE-W-UK-12-2019-Rev.1 | Part no. 10083684
EN
ENGLISH
3 Safety
3.1 Safety notices
DANGER indicates an imminent danger that
may cause serious physical injury or death
if the appropriate safety precautions are not
in place.
WARNING indicates a danger arising
through incorrect behaviour (e.g. misuse,
disregarding notices, etc.) that may cause
serious physical injury or death.
CAUTION indicates a potentially dangerous
situation that may cause minor or slight
injuries if the appropriate safety precautions
are not in place.
NOTICE indicates a situation that may
cause material damage if the corresponding
precautions are not taken.
3.2 Important safety information
• Read this operating manual carefully before use.
• Only connect this pump unit to a power supply which
matches the supply voltage stated on the pump unit's data
plate.
• The power supply on the pump unit must be disconnected
before completing any maintenance, cleaning or repair
work.
• Maintenance, cleaning and repair work may be carried out
by trained specialist personnel only.
• If the pump unit is damaged or is not functioning correctly,
it must no longer be used. In this case, contact your
specialist dealer immediately.
• Observe the maintenance instructions and intervals.
• Protect the pump unit against the effects of weather.
• Never use the pump unit outdoors.
• The device set may only be used in accordance with its
intended use.
3.3 Intended use
This pump unit is intended for distributing heating water in
heating systems.
The pump unit is completely pre-assembled, ready to install.
The pump unit is not intended for use by persons (including
children) with reduced physical, sensory or mental capabilities,
or lack of specialist knowledge or experience.
3.4 Foreseeable misuse
The following is regarded as foreseeable misuse:
• operating the pump unit contrary to the specifications.
• using the pump unit for use other than its intended use.
• making modifications to the pump unit not agreed with the
manufacturer.
• using replacement or wear parts not approved by the
manufacturer.
• operating the pump unit outdoors (parts and components
are not UV-resistant).
3.5 Operator’s responsibility
The operator must ensure that:
• the pump unit is only used for its intended purpose.
• the pump unit is installed, operated and maintained
according to the specifications in the Installation and
Operating Manual.
• the pump unit is only operated according to local directives
and occupational health and safety regulations.
• all precautions have taken to avoid hazards originating from
the pump unit.
• all precautions for first aid and fire suppression are carried
out.
• only authorised and trained users have access to and
operate the pump unit.
• users have access to this Installation and Operating Manual
at all times.
3.6 Users
Only qualified persons may operate the pump unit or carry out
service and maintenance work.
Operators
An operator is deemed to be qualified if they have read
this operating manual and understood the potential hazards
associated with improper behaviour.
Fitters/commissioners
Due to their technical training, expert knowledge and
consideration of the relevant standards, provisions, regulations
and laws, fitters/commissioners are able to carry out work on
the pump units and to identify and prevent potential hazards.