Cartridge alarm
This function generates an alert message on a predefined date to indicate that the e-Car-
tridge requires maintenance. Select Cartridge alert. By default, the cycle is set to a
period of 18 months (i.e. 539 days). If you do not wish to receive cartridge maintenance
alerts, press the key (the cursor reading "On" switches to “Off”), and confirm using .
The maintenance reminder can be set to between 6 and 36 months’ duration. The
display shows the number of days remaining until maintenance is next due. Whenever
the e-Cartridge is replaced, we recommended resetting the alert to ensure it is triggered
at the correct time. Press the key, then to select “Yes" and validate using .
7
-
Installer menu
Calibration
The mixed water probe is calibrated in the factory, but it may require recalibration if used
in a multi-probe system. Once all connections are complete and the system has been
supplied with water, select Calibration in the Configuration menu.
Run the water at the usual temperature and calibrate the mixed water temperature probe
directly on the control unit with reference to the value measured using the reference
thermometer.
Test relays
For use during installation or maintenance. Activate the relays separately to check that
the wiring is correct and the system is operating correctly. Confirm the selection “Test
relay” using the key. Select a relay using the keys , then validate using the
key (the relay should switch).
Cartridge Alarm
Status :On
Cycle :
18Months
Remaining : 537Days
Reset :
Yes
No
Cartridge Alarm
Status :
Off
Parameters
1 Date/Hour
2 Contrast
3
Languages
4 Units
5 SD Export
6
Cartridge Alarm
Cartridge Alarm
Status :On
Cycle :
18
Months
Remaining : 339Days
Reset
Cartridge Alarm
Status :On
Cycle :
6
Months
Remaining : 180Days
Reset
Installer Menu
1
Calibration
2 Relay Test
3 Forced cycle
4 Forced flushing
5 Thermal shock T°
6 T° Limitation
Calibration
Probes
- Mixed water
19.8°C
- Loopback -.-°C
Mixed T° setting
50.0
°C
Mixed water 48.8°C
Relay Test
Flushing relay
Alarm relay
Storage relay
Pump relay
Relay Test
Flushing relay
Alarm relay
Storage relay
Pump relay
Installer Menu
1 Calibration
2
Relay Test
3 Forced cycle
4 Forced flushing
5 Thermal shock T°
6 T° Limitation
Flushing relay