Follow the manufacturer’s instructions for the proper use of water preservative.

Inspect Eyewash Unit

1 .  Visually inspect the eyewash unit weekly for cleanliness and proper solution level (per ANSI Standard 

Z358 .1-2014) .

2 .  Check the sprayheads’ water spray pattern for an even, continuous flow . The sprayheads are attached 

to the arm using screws and can be detached from the tray for cleaning or obstruction removal (if 
necessary) and reattached . Use a 

⁹⁄₆₄

" hex-head Allen wrench to remove and reinstall the sprayheads

3 .  Check the water supply hose at the basin of the eyewash unit for cracks, leaks, or wear .
4 .  Check the entire unit for possible water leakage .

 

Minor weeping from the snorkel outlet may occur. Weeping is caused by an elevated water level in the cup 
due to environmental variables such as barometric pressure and temperature. If desired, cycle the eyewash 
to re-normalize the water level in the cup and stop the weeping.

5 .  Check the solution for contamination and replace with fresh solution, if necessary .

 

Activate the eyewash unit each time the solution is replaced to ensure proper operation. If the unit is not 
working properly, remove it from the hazard area and contact Bradley Company immediately. 

Clean Eyewash Unit

When using potable water and water preservative (recommended):

1 .  Carefully remove the eyewash tank from the pedestal and drain the water solution from the tank 

(dispose of the solution properly) . For ease of draining, the pedestal has a drain hole which will accept 
a ½" I .D . tube at the underside of the hole (tube supplied by others) (see page 5 for drain hole location) .

2 .  Clean the inside of the tank using warm water and a mild soap product; rinse thoroughly . 
3 .  Refill the eyewash tank following the procedures outlined in Step 2 found on page 4 . Follow instructions 

of the preservative manufacturer for the proper use of water preservative .

4 .  Reinstall the eyewash tank following the procedure outlined in Step 2 found on page 4 .

When using potable water only:

1 .  Empty the tank any time from once per week to once per month, depending on the quality of your 

water supply . The manufacturer is not responsible for variations in the water supply .

2 .  Clean the inside of the tank using warm water and mild soap . Rinse the tank thoroughly with warm 

water . 

3 .  Refill the eyewash tank with tepid potable water .

To operate eyewash unit:

1 .  Begin operation by pulling down the tray .
2 .  Hold eyelids open with thumbs and forefingers . Rotate eyes back 

and forth to ensure a complete rinse . Allow water to bathe both 
eyes simultaneously for a minimum of 15 minutes .

3 .  Seek medical attention immediately after use .

 

Do not lean on the eyewash tray when in the opened position.  
Damage to unit may result.

Summary of Contents for Bradley S19-921

Page 1: ...es de instalaci n 14 Instrucciones de mantenimiento 16 PLEASE READ As of August 31 2011 Bradley has discontinued the manufacturing and sale of Kleersight Ultra Concentrate Water Preservative Unfortuna...

Page 2: ...estions regarding the operation or installation of this product visit www bradleycorp com or call 1 800 BRADLEY Product warranties and parts information may also be found under Products on our website...

Page 3: ...9 Hook and Loop Fastener Kit 269 1781 contains 5 sets Bumper for Tank Hold Down Latch 269 1861 contains 5 bumpers Mounting Bracket 140 820 Clamp 146 072 Snorkel 198 016 Tube 269 1385 Latch Replacement...

Page 4: ...k is to full 2 Add water preservative not included to the eyewash tank Follow the manufacturer s instructions for the proper use of water preservative 3 Add clean potable tepid water to the tank until...

Page 5: ...8 1 2014 When the water level drops below the 15 minute fill line the tank must be emptied and then refilled To refill the eyewash tank follow the procedures outlined in Step 2 found on page 4 2 Attac...

Page 6: ...Clean Eyewash Unit When using potable water and water preservative recommended 1 Carefully remove the eyewash tank from the pedestal and drain the water solution from the tank dispose of the solution...

Page 7: ...iante sup rieures 38 C ou inf rieures 16 C Installation P O BOX 309 MENOMONEE FALLS WI 53052 0309 USA TEL 1 800 BRADLEY FAX 262 251 5817 http www bradleycorp com 114 051 P O Box 309 Me nom one e Fal l...

Page 8: ...69 1379 Paquet d attaches de tissu pour attacher l etiquette l unit 269 1781 contient 5 ensembles Support Mural 140 820 Pince 146 072 Tuyau 269 1385 Paquet d attache de rechange S45 2194 Paquet d join...

Page 9: ...utilisation de l agent de conservation de l eau fournies avec ce produit 3 Continuer de remplir le r servoir avec de l eau ti de potable jusqu ce qu il atteigne la pleine ligne 4 Ins rer le coupe d b...

Page 10: ...ion est en de de la ligne de remplissage de 15 minutes le r servoir doit tre vid et rempli nouveau Remplir le r servoir de la douche oculaire selon les directives d crites l tape 2 de la page 9 2 Atta...

Page 11: ...pr servatif de l eau recommand s 1 Enlever doucement le r servoir de la douche oculaire de son socle et drainer le m lange d eau du r servoir disposer du m lange de fa on appropri e Pour faciliter le...

Page 12: ...ngada a fuentes de calor ambiental por sobre los 38 C 100 F y bajo los 16 C 60 F Installation P O BOX 309 MENOMONEE FALLS WI 53052 0309 USA TEL 1 800 BRADLEY FAX 262 251 5817 http www bradleycorp com...

Page 13: ...rador 152 064 Tubo esn rquel 198 016 Letero de seguridad 114 051 tiqueta de emergencia 204 421 Tanque 133 152 HDPE Blanco Tapa Perforada 136 036 Tapaflujo 269 1379 Paquete de sujetadores de la tela pa...

Page 14: ...clu da en el tanque del lavador de ojos Para darle el uso adecuado al conservante de agua siga las instrucciones del fabricante del producto 3 Vierta m s agua potable tibia en el tanque hasta que el a...

Page 15: ...l nea de llenado de 15 minutos se debe vaciar y volver a llenar el tanque Llene el tanque del lavador de ojos siguiendo el procedimiento descrito en el Paso 2 de la p gina 14 2 Fije la etiqueta de in...

Page 16: ...del agua recomendados 1 Separe cuidadosamente el tanque del pedestal y drene la soluci n del tanque disponga de la soluci n apropiadamente Para facilitar el drenaje el pedestal tiene un orificio de dr...

Reviews: