Performance Data Sheet
for specific claims to NSF Std-53.
CT-1, UC-1, UC-2 & Ultra-UV-R
GENERAL USE CONDITIONS:
1: System to be used with municipal or well water sources treated and tested on regular basis to insure bacteriological safe
quality. DO NOT use with water that is microbiologically unsafe or unknown quality without adequate disinfection before
and after the system. “Systems certified for cyst reduction may be used on disinfected water that may contain filterable
cysts.”
2: Operating Temperature:
Maximum
100
o
F (40.5
o
C)
Minimum 40
o
F (4.4
o
C)
3: Operating Water Pressure:
Maximum
100-psi (7.43 kg/cm
2
)
Minimum 20-psi
4: Turbidity:
< 5 NTU
5: pH:
6.0 to 8.5
6: Maximum flow Rate:
0.50 gpm (1.89 lpm)
RECOMMENDED REPLACEMENT PARTS AND CHANGE INTERVAL:
Note: Depending on incoming feed water conditions replacement time frame may vary.
Description
Units
Change time Frame
Stage 1: sediment: 5M-10
UC-2 & Ultra-UV-R
6 Months or 1350 gallons of water
1 Micron Carbonblock P-CB-1:
CT-1, UC-1, UC-2 & Ultra-UV-R
6 Months or 1350 gallons of water
170019 UV Replacement Lamp
Ultra-UV-R
12 months or 9000 hours
Testing parameters:
Flow rate 0.5 gpm
pH 6.5 and 8.5
Water pressure: 50 psi.
Cyst Reduction
Gallons
Influent Effluent
1
Effluent
2
Influent Avg.
155500
count/ml
Fourth Cycle
98000
15
44
Effluent Avg.
28
count/ml
25%
94000
4
15
Percent Reduction
99.98 %
50%
160000
9
39
Maximum Effluent
81
count/ml
75%
270000
17
81
Lead Reduction 6.5 pH
Gallons Sample Pt
InfluentEffluent
1
Effluent
2
Influent Avg.
0.16 mg/l
0
Start-up 0.16
0.001
0.0013
Effluent Avg.
0.0024 mg/l
675
75%
0.16
0.001
0.001
Percent Reduction
98.5 %
1350
100%
0.16
0.0031
0.001
Maximum Effluent
0.0088 mg/l
2025
150%
0.17
0.0047
0.001
2430
180%
0.17
0.0088
0.001
Lead Reduction 8.5 pH
Gallons Sample Pt
InfluentEffluent
1
Effluent
2
Influent Avg.
0.16 mg/l
0
Start-up 0.16
0.0017
0.01
Effluent Avg.
0.0032
675
75%
0.16
0.001
0.001
Percent Reduction
98 %
1350
100%
0.17
0.001
0.001
Maximum Effluent
0.01 mg/l
2025
150%
0.14
0.0033
0.0058
2430
180%
0.16
0.0058
0.0011
That the systems conform to ANSI/NSF 53 for specific performance claims as verified and substantiated by test data.
REFER TO OWNER’S INSTALLATION/SERVICE MANUAL FOR FURTHER MAINTENANCE REQUIREMENTS, AND
WARRANTY INFORMATION.