Cut the tube square. It is essential that the outside diame-

ter be free of score marks and that burrs and sharp edges 

be removed before inserting into fitting.

Make certain to push the tubing completely into the con-

nector until it comes into contact with the internal tubing 

stop.  The collet (gripper) has stainless steel teeth which 

hold the tube firmly in position while the O-ring provides a 

permanent leak proof seal.
Pull on the tube to check that it is secure. It is a good 

practice to test the system prior to leaving the site and/or 

before use.

To disconnect, ensure the system is depressurized before 

removing the tube. Push in collet squarely against the face 

of the fitting. With the collet held in this position, the tube 

can be removed. The fitting can then be reused.

Cutting

Connecting

Disconnecting

Using Quick-Connect Fittings

System Diagram

3

G

D

E

F

A

B

C

Parts List

Item Part#

Description

A

560080

Adapt-A-Valve

B

142000

Green Tube

C

142001

Blue Tube

D

105311

Sediment Filter

E

105371

LVOC Carbon Filter

F

105321

UF Membrane

G

116113

Brushed Nickel Faucet

Summary of Contents for Filter Pure UF3

Page 1: ...uture reference WARNING Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system If you are unsure about installing your WA...

Page 2: ...mbrane filtration process which uses standard home water pressure to push water through its semi permeable membrane Suspended particles and materials of high molecular weight are unable to pass throug...

Page 3: ...agram 5 Drill a Hole for the Faucet in a Porcelain Sink 6 Or Punch a Hole for the Faucet in a Stainless Steel Sink 6 Faucet Installation 7 Adapt a Valve Installation 8 Green Tube Connection 8 Mounting...

Page 4: ...0 5 gpm 60 psi Contents of Under Counter System Please make sure all of the items listed below are contained in the box If any of the items are missing please contact Watts Premier at 800 752 5582 pri...

Page 5: ...e tube to check that it is secure It is a good practice to test the system prior to leaving the site and or before use To disconnect ensure the system is depressurized before removing the tube Push in...

Page 6: ...lowest speed drill a 1 8 pilot hole through both porcelain and metal casing of sink at the marked center of the desired location Use lubricating oil or liquid soap to keep the drill bit cool If drill...

Page 7: ...eeve small tapered end of sleeve must point to the end of tube and then insert the plastic insert all the way into the end of the tube Step 9 Push the assembled tube into the threaded stem until it st...

Page 8: ...connect fitting located behind the Sediment filter Make sure to push the tube in all the way to the tube stop Step 15 Take the other end of the 1 4 Green tube and insert into the 1 4 quick connect fit...

Page 9: ...nstallation of your new water filtration system Please Follow the Startup Instructions Step 1 Turn on water supply at angle stop and open the Adapt a Valve Turn faucet handle to the open position to s...

Page 10: ...a towel under the filter module to catch any excess water that may drip out from the filters during the changeover Step 2 To remove a filter cartridge Push hold the button on the valved head above th...

Page 11: ...0 08 0 001 CIS 1 3 DICHLOROPROPYLENE 99 0 079 0 001 Performance Data Sheet Watts Premier 8716 W Ludlow Drive Suite 1 Peoria AZ 8538 Model Filter Pure UF3 GENERAL USE CONDITIONS 1 Do not use with wate...

Page 12: ...ZENE see CHLOROBENZENE 99 0 077 0 001 PCE see TETRACHLOROETHYLENE 99 0 081 0 001 PENTACHLOROPHENOL 99 0 096 0 001 PERCHLOROBUTADIENE see HEXACHLOROBUTADIENE 98 0 044 0 001 PROPYLENE DICHLORIDE see 1 2...

Page 13: ...mber _______________ Serial Number _______________ Date of Install _________________ Installed by __________________ Date Sediment Filter 6 Months Carbon Block 6 Months UF Membrane 12 Months Date Sedi...

Page 14: ...water to the Counter Top cannot exceed 100 degrees F 38 degrees C This warranty does not cover any equipment that is relocated from the site of its original installation This warranty does not cover a...