Page 23
RECOMMENDED REPLACEMENT PARTS AND CHANGE INTERVALS:
Depending on incoming feed water conditions replacement time frame may vary.
Change Time
Description
6 months:
Sediment Pre-filter; Carbon Pre-filters
12 months
Final Carbon filter
2 to 5 years
R.O. Membrane
This system has been tested according to NSF/ANSI 58 for reduction of the substances below. The concentration of the indicated substances in
water enter�
ed in
NSF/ANSI 58. This system has been tested for the treatment of water containing pentavalent arsenic (also known as As (V), As (+5), or arsenate)
at concentrations of 0.30 mg/L or less. This system reduces pentavalent arsenic, but may not remove other forms of arsenic. This system is to
be used on water supplies containing a detectable free chlorine residual at the system inlet or on water supplies that have been demonstrated to
contain only pentavalent arsenic. Treatment with chloramine (combined chlorine) is not sufficient to ensure complete conversion of trivalent arsenic
to pentavalent arsenic. Please see the Arsenic Facts section of the Performance Data Sheet for further information.
Avg. In.
Avg. Eff.
% Reduction pH
Pressure Max Eff. Inf. challenge
Max Allowable
concentration
concentration
mg/L
mg/L
Arsenic (Pentavalent) 334.615 ug/L 5.0385 ug/L
98.4%
50psi
19 ug/L
0.30±10%
0.010
Barium Reduction
10.2 mg/L
0.207 mg/L
97.9%
7.24
50psi
0.3 mg/L
10.0±10%
2.0
Cadmium Reduction
0.036 mg/L 0.0005 mg/L
98.6%
7.49
50psi
0.0007
0.3±10%
0005
Chromium (Hexavalent) 0.15 mg/L
0.013 mg/L
91.3%
7.24
50psi
0.03
0.3±10%
0.1
Chromium (Trivalent)
0.17 mg/L
.01 mg/L
94.1%
7.24
50psi
0.01
0.03±10%
0.1
Copper Reduction
3.1 mg/L
0.03 mg/L
99.0%
7.64
50psi
0.04
3.0±10%
1.3
Cysts
222,077#/ml
10 #/ml
99.99%
58 minimum 50,000/mL
Fluoride Reduction
8.0 mg/L
0.5 mg/L
93.9%
7.49
50psi
0.7
8.0±10%
1.5
Lead Reduction
0.15 mg/L
0.002 mg/L
98.6%
7.49
50psi
0.003
0.15±10%
0.010
Nitrate & Nitrite
28.8 mg/L
6.6 mg/L
77.0%
50 psi
10 mg/L
30±10%
10.0
Nitrate
26.0 mg/L
6.1 mg/L
76.5%
50 psi
10 mg/L
27±10%
10.0
Nitrite
2.8 mg/L
0.5 mg/L
82.1%
50 psi
0.77mg/L
3.0±10%
1.0
Perchlorate
0.10 mg/L
0.003 mg/L
96.5%
7.39
50 psi
0.005 mg/L
0.10±10%
0.006
Radium 226/228
25 pCi/L
5 pCi/L
80.0%
7.24
50psi
5 pCi/L
25pCiL±10%
5 pCi/L
Selenium
0.10
0.008
92.0%
50psi
0.011
0.10±10%
0.05
TDS
765
23
96.8%
7.84
750±40mg/L
187
Turbidity
10.2 mg/L
0.26 mg/L
97.5%
0.83
11±1 NTU
0.5 NTU
RECOVERY - 16.34%
GALLONS - 17.32 GPD
EFFICIENCY - 8.91%
Efficiency rating means the percentage of the influent water to the system that is available to the user as reverse osmosis treated water under operating
conditions that approximate typical daily usage.
Recovery rating means the percentage of the influent water to the membrane portion of the system that is
available to the�
There
is an average of 4 gallons of reject water for every 1 gallon of product water produced. Testing performed under standard laboratory conditions, actual
performance may vary. Refer to owners manual for further maintenance requirements and warranty information.
Phone: (623) 931-1977
Fax: (623) 931-0191
Email: wpmail@wattsind.
GENERAL USE CONDITIONS:
1. S�
. Do not use
with wate�
ed for cyst
reduction may be used on disinfected water that may contain filterable cysts.
2. This system is acceptable for treatment of influent concentrations of no more than 27 mg/L nitrate and 3 mg/L nitrite in combination measured as
N and is certified for nitrate/nitrite reduction only for water supplies with a pressure of 280 kPa (40 psig) or greater. If your water supply is under 40
psi, Watts Premier recommends the use of a RO booster pump for proper operation.
3. Operating Temperature:
Maximum: 100°F (40.5°C)
Minimum: 40° (4.4°)
4. Operating Water Pressure:
Maximum: 85 psi (7.0kg/cm2)
Minimum: 40 psi (2.8kg/cm2)
5. pH
2 to 11
6. Hardness of more than 10 grains per gallon (170 ppm) may reduce TFM membrane life expectancy.
7. Recommend TDS (Total Dissolved Solids) not to exceed 1800 ppm.
Watts Premier Inc.
1725 W. Williams Drive C-20
Phoenix, AZ 85027 USA
(623) 931-1977 [email protected]
Performance Data Sheet
B-RO5M-50, WP5-50