Using the digital operator
Page 40 / 52
Jogging stop mode
A 39
N
When a stop command is issued during activated jogging mode,
the motor stops by:
00: running free
01: decelerating using configured deceleration time
02: decelerating using DC brake
00
Function
Display *)
Function description / parameter setting range
Standard
setting
Set
values
Voltage/frequency characteristics, boost
V
f in Hz
5.0
0
100%
25.0
A 43
=10%
50.0Hz
A 42
=50%
Parameter settings:
A 41
=00
A 42
=50
A 43
=10.0
A 44
=00
A 45
=100
Boost selection
method
A 41
N
Selection of:
00: manual boost
or
01: automatic boost
00
Voltage rise,
manual boost
A 42
Y
The amount of voltage rise in manual boost mode can be set in
the range of 0% to 99%.
11
Manual boost fre-
quency adjustment
A 43
Y
The frequency where the highest voltage rise exists can be set in
the range of 0% to 50% of the base frequency.
10.0
Voltage/frequency
characteristic
A 44
N
V
100%
0
f
constant
quadratic
00
Output voltage gain
A 45
Y
V
100%
0
f
50%
100
Function
Display *)
Function description / parameter setting range
Standard
setting
Set
values
DC braking
L2000 series inverters have a configurable DC brake that is activated as soon as the stop command is issued. By
applying a strobed DC voltage to the motor’s stator a braking torque is induced into the rotor that effectively works
against the rotation of the motor. Usage of the DC brake makes possible high registration accuracy when carrying
out positioning work.
CAUTION
Usage of the DC brake causes an additional heating of the motor. For this reason the DC
brake should be configured with as short a braking torque and braking time as possible.
DC brake
active / not active
A 51
N
00: DC brake is not used (not)
01: DC brake is used (active)
00
DC brake
frequency
A 52
N
The DC brake will be activated as soon as the actual output
frequency falls below the frequency entered here. Setting range
0.5Hz–10Hz.
0.5
DC brake
waiting time
A 53
N
When the frequency set under
A 52
is reached the motor runs
free for the duration entered here. Only after this duration the DC
brake is activated. Setting range 0.0s–5s.
0.0
DC brake
braking torque
A 54
N The amount of braking force can be entered here. Setting 0%–
100%.